scholarly journals A Novel Generator Design Utilised for Conventional Ejector Refrigeration Systems

Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7705
Author(s):  
Anas F. A. Elbarghthi ◽  
Mohammad Yousef Hdaib ◽  
Václav Dvořák

Ejector refrigeration systems are rapidly evolving and are poised to become one of the most preferred cooling systems in the near future. CO2 transcritical refrigeration systems have inherently high working pressures and discharge temperatures, providing a large volumetric heating capacity. In the current research, the heat ejected from the CO2 gas cooler was proposed as a driving heating source for the compression ejector system, representing the energy supply for the generator in a combined cycle. The local design approach was investigated for the combined plate-type heat exchanger (PHE) via Matlab code integrated with the NIST real gas database. HFO refrigerants (1234ze(E) and 1234yf) were selected to serve as the cold fluid on the generator flowing through three different phases: subcooled liquid, a two-phase mixture, and superheated vapour. The study examines the following: the effectiveness, the heat transfer coefficients, and the pressure drop of the PHE working fluids under variable hot stream pressures, cold stream flow fluxes, and superheated temperatures. The integration revealed that the cold fluid mixture phase dominates the heat transfer coefficients and the pressure drop of the heat exchanger. By increasing the hot stream inlet pressure from 9 MPa to 12 MPa, the cold stream two-phase convection coefficient can be enhanced by 50% and 200% for R1234yf and R1234ze(E), respectively. Conversely, the cold stream two-phase convection coefficient dropped by 17% and 37% for R1234yf and R1234ze(E), respectively. The overall result supports utilising the ejected heat from the CO2 transcritical system, especially at high CO2 inlet pressures and low cold channel flow fluxes. Moreover, R1234ze(E) could be a more suitable working fluid because it possesses a lower pressure drop and bond number.

2020 ◽  
Vol 10 (15) ◽  
pp. 5225
Author(s):  
Barbara Arevalo-Torres ◽  
Jose L. Lopez-Salinas ◽  
Alejandro J. García-Cuéllar

The curved geometry of a coiled flow inverter (CFI) promotes chaotic mixing through a combination of coils and bends. Besides the heat exchanger geometry, the heat transfer can be enhanced by improving the thermophysical properties of the working fluid. In this work, aqueous solutions of dispersed TiO2 nanometer-sized particles (i.e., nanofluids) were prepared and characterized, and their effects on heat transfer were experimentally investigated in a CFI heat exchanger inserted in a forced convective thermal loop. The physical and transport properties of the nanofluids were measured within the temperature and volume concentration domains. The convective heat transfer coefficients were obtained at Reynolds numbers (NRe) and TiO2 nanoparticle volume concentrations ranging from 1400 to 9500 and 0–1.5 v/v%, respectively. The Nusselt number (NNu) in the CFI containing 1.0 v/v% nanofluid was 41–52% higher than in the CFI containing pure base fluid (i.e., water), while the 1.5 v/v% nanofluid increased the NNu by 4–8% compared to water. Two new correlations to predict the NNu of TiO2–water nanofluids in the CFI at Reynolds numbers of 1400 ≤ NRe ≤ 9500 and nanoparticle volume concentrations ranges of 0.2–1.0 v/v% and 0.2–1.5 v/v% are proposed.


2002 ◽  
Vol 124 (5) ◽  
pp. 975-978 ◽  
Author(s):  
Li Yong and ◽  
K. Sumathy

Quasi-local absorption heat transfer coefficients and pressure drop inside a horizontal tube absorber have been investigated experimentally, with R-22/DMA as the working pair. The absorber is a counterflow coaxial tube-in-tube heat-exchanger with the working fluid flowing in the inner tube while the water moves through the annulus. A large temperature gliding has been experienced during the absorption process. Experimental results show that the heat transfer coefficient of the forced convective vapor absorption process is higher compared to the vertical falling film absorption. A qualitative study is made to analyze the effect of mass flux, vapor quality and solution concentration on pressure drop and heat transfer coefficients. On the basis of the experimental results, a new correlation is proposed whereby the two-phase heat transfer is taken as a product of the forced convection of the absorption and the combined effect of heat and mass transfer at the interface. The correlation is found to predict the experimental data almost within 30 percent.


Author(s):  
Cheol Huh ◽  
Moo Hwan Kim

With a single microchannel and a series of microheaters made with MEMS technique, two-phase pressure drop and local flow boiling heat transfer were investigated using deionized water in a single horizontal rectangular microchannel. The test microchannel has a hydraulic diameter of 100 μm and length of 40 mm. A real time observation of the flow patterns with simultaneous measurement are made possible. Tests are performed for mass fluxes of 90, 169, and 267 kg/m2s and heat fluxes of from 100 to 600 kW/m2. The experimental local flow boiling heat transfer coefficients and two-phase frictional pressure gradient are evaluated and the effects of heat flux, mass flux, and vapor qualities on flow boiling are studied. Both the evaluated experimental data are compared with existing correlations. The experimental heat transfer coefficients are nearly independent on mass flux and the vapor quality. Most of all correlations do not provide reliable heat transfer coefficients predictions with vapor quality and prediction accuracy. As for two-phase pressure drop, the measured pressure drop increases with the mass flux and heat flux. Most of all existing correlations of two-phase frictional pressure gradient do not predict the experimental data except some limited conditions.


Author(s):  
Seungwhan Baek ◽  
Sangkwon Jeong

Mixed Refrigerant Joule Thomson (MR-JT) refrigerators are widely used in various kinds of cryogenic systems these days. Although heat transfer coefficient estimation for a multiphase and multi-component fluid in cryogenic temperature range is necessarily required in the heat exchanger design of MR-JT refrigerator, it has been rarely discussed so far. In this paper, condensation and evaporation heat transfer coefficients of mixed refrigerant are measured in a microchannel heat exchanger. Printed Circuit Heat Exchanger (PCHE) has been developed as a compact microchannel heat exchanger and used in the experiment. Several two-phase heat transfer coefficient correlations are examined to discuss the experimental measurement results. The result of this paper shows that cryogenic mixed refrigerant heat transfer coefficients can be estimated by conventional two-phase heat transfer coefficient correlations.


Author(s):  
C. Aprea ◽  
A. Greco ◽  
G. P. Vanoli

R22 is the most widely employed HCFC working fluid in vapour compression plant. HCFCs must be replaced within 2020. Major problems arise with the substitution of the working fluids, related to the decrease in performance of the plant. Therefore, extremely accurate design procedures are needed. The relative sizing of each of the components of the plant is crucial for cycle performance. For this reason, the knowledge of the new fluids heat transfer characteristics in condensers and evaporators is required. The local heat transfer coefficients and pressure drop of pure R22 and of the azeotropic mixture R507 (R125-R143a 50%/50% in weight) have been measured during convective boiling. The test section is a smooth horizontal tube made of a with a 6 mm I.D. stainless steel tube, 6 m length, uniformly heated by Joule effect. The effects of heat flux, mass flux and evaporation pressure on the heat transfer coefficients are investigated. The evaporating pressure varies within the range 3 ÷10 bar, the refrigerant mass flux within the range 200 ÷ 1000 kg/m2s, the heat flux within 0 ÷ 44 kW/m2. A comparison have been carried out between the experimental data and those predicted by means of the most credited literature relationships.


Author(s):  
Alexey Vasilievich Ezhov ◽  
Sergey Sergeevich Ivanov ◽  
Aleksandr Bukin ◽  
Vladimir Grigorievich Bukin

The paper presents the results of an experimental study of the effect of oil on the heat transfer rate at boiling of mixed refrigerant R406A. Since the air conditioning system is not a pure refrigerant, but a mixture of oil with a concentration of up to 8%, such an amount of oil affects both hydrodynamics and heat exchange in the evaporators. The experimental work covers the entire range of regime parameters typical for these systems. There is shown the process of changing oil concentration in the pipe, as the working fluid boils, proving that most of the oil pipe does not impair the heat exchange in the course of two-phase flow boiling. Different modes of refrigerant R406A boiling dynamics have been defined, and each mode is given a quantitative assessment in terms of the effects of the oil and explaining of this effect on the fluid flow and heat transfer based on visual observations and the experiment results. The main factor of the effect is the freon-oil foam, which increases the proportion of the wetted surface in the wave and stratified modes and the heat transfer rate to 30%. A comparison of the heat transfer coefficients both in the cross section and along the pipe length has been performed, showing that the maximum change in heat transfer occurs in the upper part of the surface due to developing a dry wall on it and wetting it with freon-oil foam. A comparison of the heat transfer rate of pure refrigerant R406A has been done; the presence of oil in it shows that the effect of oil is complex and ambiguous. Calculation and criterion dependences for calculation of heat transfer coefficients in different modes have been proposed.


Author(s):  
Serguei Dessiatoun ◽  
Sourav Chowdhury ◽  
Ebrahim Al-Hajri ◽  
Edvin Cetegen ◽  
Michael Ohadi

Three different refrigerants, R134a, R245fa and HFE7100 were analyzed as working fluids for two-phase cooling of high heat flux electronics in a 0.7 mm hydraulic diameter 190 mm long high aspect ratio minichannel and in a newly developed micro-groove surface condenser. The latter comprised of a micro-groove surface with rectangular grooves of 84 μm in hydraulic diameter with an aspect ratio of 10.6 and headers that directed the refrigerant flow into the grooves. It was concluded that in the minichannel R245fa provides higher heat transfer coefficients compared to R134a with a significantly higher pressure drop. The saturation temperature drop in the same channel created a significant temperature drop for HFE7100 that make the application of such minichannels for cross-flow condensers with this fluid unpractical. The microgroove surface condenser provided significantly higher heat transfer coefficients compared to the minichannel condenser. The pressure drop in the micro-groove surface condenser was extremely low and imposed just 1C temperature drop on HFE7100 at it highest heat flux. The mass flux of refrigerant in the micro-groove surface condenser is significantly lower compared to conventional mini and microchannel condensers. In its current configuration, the microgroove surface condenser benefits from the possibility of an increase in mass flux resulting in a significant increase in heat transfer coefficient and just a moderate increase in pressure drop.


2017 ◽  
Vol 25 (02) ◽  
pp. 1750013 ◽  
Author(s):  
Pham-Quang Vu ◽  
Kwang-Il Choi ◽  
Jong-Taek Oh ◽  
Honggi Cho

The condensation heat transfer coefficients and pressure drops of R410A and R22 flowing inside a horizontal aluminum multiport mini-channel tube having 18 channels are investigated. Experimental data are presented for the range of vapor quality from 0.1 to 0.9, mass flux from 50 to 500[Formula: see text]kg/m2s, heat flux from 3 to 15[Formula: see text]kW/m2 and the saturation temperature at 48[Formula: see text]C. The pressure drop across the test section was directly measured by a differential pressure transducer. At a small scale, the noncircular cross-sections can enhance the effect of the surface tension. The average heat transfer coefficient increased with the increase of vapor quality, mass flux and heat flux. Under the same test conditions, the heat transfer coefficients of R22 are higher than those for R410A, the pressure drops for R410A are 7–19% lower than those of R22. The lower pressure drop of R410A has an important advantage as an alternative working fluid for R22 in air-conditioning and heat pump systems.


2017 ◽  
Vol 25 (01) ◽  
pp. 1750005 ◽  
Author(s):  
Benedict Prah ◽  
Rin Yun

The formation of CO2 hydrate during CO2 transportation presents a complex two-phase flow within tube. A two-dimensional CFD model for CO2 hydrate mixture flow in tube is derived based on the Eulerian multiphase flow modeling approach in which the two phases consist of CO2 gas and CO2 hydrate particles. A coupled Eulerian multiphase and nonisothermal flow model without phase-change is developed based on COMSOL Multiphysics built-in application modes. The model couples the mass, momentum, and energy equations for the two phases to solve the temperature and flow characteristics of the CO2 hydrate mixture flow in tube. CO2 hydrate particles are found to settle down during flow even under high velocity operation. The pressure drop increased linearly with inlet volume fraction from 1.29[Formula: see text]kPa for 0.1–5.2[Formula: see text]kPa for 0.5, and the related overall heat transfer coefficients of the CO2 hydrate mixture computed from the model ranged from 980 to 4000[Formula: see text]W/m2K with variation of CO2 hydrate volume fraction.


Author(s):  
Chunyu Yin ◽  
Xiaoyong Yang ◽  
Jie Wang

Recuperator is one of the key components in the helium-turbine cycle coupled with High Temperature Gas cooled Reactor (HTGR). Synthetically considering the heat transfer coefficients, the pressure drop and installation space of recuperator, it is obviously a trend to use compact heat exchanger as recuperator in nuclear power plant. Recuperator recovers heat from the turbine exhaust gas. It promotes the cycle efficiency over entire power range and in all typical modes including start up and shut down modes. The recuperator’s heat transfer coefficients, height, pressure drop have effect on the recuperator’s effectiveness. The main purpose of this paper is to present the law of heat transfer and flow resistance in laminar flow compact exchanger. Based on the similarity theory, the dimensionless parameters of the plate-fin heat exchanger is given in this paper; and then the the dimensionless analysis of the over-all heat transfer coefficient, recuperator’s effectiveness and flow resistance is presented. Furthermore, relationship between the pressure drop and length is also developed.