The Effects of Air Infiltration on a Large Flat Heat Pipe at Horizontal and Vertical Orientations

2003 ◽  
Vol 125 (2) ◽  
pp. 349-355 ◽  
Author(s):  
M. Cerza ◽  
B. Boughey

In the satellite or energy conversion industries flat heat pipes may be utilized to transfer heat to the thermal sink. In this investigation, a large flat heat pipe, 1.22m×0.305m×0.0127m, fabricated from 50 mil Monel 400 metal sheets and Monel 400 screens was videographed at horizontal and vertical orientations with an infrared video camera. The heat pipe evaporator section consisted of a 0.305m×0.305m area (one heated side only) while the side opposite the heated section was insulated. The remaining area of the heat pipe served as the condenser. In the horizontal orientation the heated section was on the bottom. In the vertical orientation the evaporator was aligned below the condenser. The sequence of photographs depicts heat inputs ranging from 200 W to 800 W, and the effect of air infiltration on heat pipe operation for both orientations. For the horizontal orientation, the air is seen to recede towards the small fill pipe as the heat input is increased. For the vertical orientation, the air and water vapor exhibit a buoyant interaction with the result that the air presence inhibits heat transfer by rendering sections of the condenser surface ineffective. The effects depicted in this paper set the stage for future analytical and experimental work in flat heat pipe operation for both normal and variable conductance modes.

Author(s):  
Lilin Chu ◽  
Yulong Ji ◽  
Chunrong Yu ◽  
Yantao Li ◽  
Hongbin Ma ◽  
...  

Abstract In order to understand the heat transfer performance, startup and fluid flow condition of oscillating heat pipe (OHP) with hydraulic diameter far exceeding the maximum hydraulic diameter (MHD), an experimental investigation on heat transfer performance and visualization was conducted. From the experimental performance, it is found that the OHP can still work well with ethanol as the working fluid when the tube diameter has exceeded the MHD of 91.6%. In addition, the detailed flow patterns of the OHP were recorded by a highspeed camera for vertical and horizontal orientation to understand its physical mechanism. In the vertical orientation, initially working fluid generates small bubbles, and then the small bubbles coalesce and grow to vapor plugs, the vapor plugs finally pushes the liquid slugs to oscillate in the tube. In the horizontal orientation, the working fluid surface fluctuates due to the vapors flow from the evaporator to the condenser and bubbles burst in the evaporator. When the peak of liquid wave reaches the upper surface of tube, a liquid slug has been formed, and then the steam flow pushes the liquid slugs to oscillate in the tube.


Perception ◽  
2021 ◽  
pp. 030100662110065
Author(s):  
Klaus Landwehr

The Oppel–Kundt illusion consists in the overestimation of the length of filled versus empty extents. Two experiments explored its relation to the horizontal-vertical illusion, which consists in the overestimation of the length of vertical versus horizontal extents, and to the oblique effect, which consists in poorer discriminative sensitivity for obliquely as opposed to horizontally or vertically oriented stimuli. For Experiment 1, Kundt’s (1863) original stimulus was rotated in steps of 45° full circle around 360°. For Experiment 2, one part of the stimulus remained at a horizontal or vertical orientation, whereas the other part was tilted 45° or 90°. The Oppel–Kundt illusion was at its maximum at a horizontal orientation of the stimulus. The illusion was strongly attenuated with L-type figures when the vertical part was empty, but not enhanced when this part was filled, suggesting that the horizontal-vertical illusion only acts on nontextured extents. There was no oblique effect.


2021 ◽  
pp. 1-13
Author(s):  
Melek Deniz Paker ◽  
Murat Cinar

Abstract A significant portion of world oil reserves reside in naturally fractured reservoirs and a considerable amount of these resources includes heavy oil and bitumen. Thermal enhanced oil recovery methods (EOR) are mostly applied in heavy oil reservoirs to improve oil recovery. In situ combustion (/SC) is one of the thermal EOR methods that could be applicable in a variety of reservoirs. Unlike steam, heat is generated in situ due to the injection of air or oxygen enriched air into a reservoir. Energy is provided by multi-step reactions between oxygen and the fuel at particular temperatures underground. This method upgrades the oil in situ while the heaviest fraction of the oil is burned during the process. The application of /SC in fractured reservoirs is challenging since the injected air would flow through the fracture and a small portion of oil in the/near fracture would react with the injected air. Only a few researchers have studied /SC in fractured or high permeability contrast systems experimentally. For in situ combustion to be applied in fractured systems in an efficient way, the underlying mechanism needs to be understood. In this study, the major focus is permeability variation that is the most prominent feature of fractured systems. The effect of orientation and width of the region with higher permeability on the sustainability of front propagation are studied. The contrast in permeability was experimentally simulated with sand of different particle size. These higher permeability regions are analogous to fractures within a naturally fractured rock. Several /SC tests with sand-pack were carried out to obtain a better understanding of the effect of horizontal vertical, and combined (both vertical and horizontal) orientation of the high permeability region with respect to airflow to investigate the conditions that are required for a self-sustained front propagation and to understand the fundamental behavior. Within the experimental conditions of the study, the test results showed that combustion front propagated faster in the higher permeability region. In addition, horizontal orientation almost had no effect on the sustainability of the front; however, it affected oxygen consumption, temperature, and velocity of the front. On the contrary, the vertical orientation of the higher permeability region had a profound effect on the sustainability of the combustion front. The combustion behavior was poorer for the tests with vertical orientation, yet the produced oil AP/ gravity was higher. Based on the experimental results a mechanism has been proposed to explain the behavior of combustion front in systems with high permeability contrast.


Author(s):  
Shigeki Hirasawa ◽  
Tatsuya Nakamu ◽  
Tsuyoshi Kawanami ◽  
Katsuaki Shirai

The coupling of the electrocaloric effect in thin films with thermal switches has the potential to be used for efficient refrigeration. We studied the unsteady heat transfer performance and periodic thermal-switching behavior of a flat heat pipe to transfer cold energy from a changing heat source. The condenser of the flat heat pipe was the changing heat source and changed from −20 W to +20 W every 5 s. The temperature of the condenser surface changed in accordance with the heat generation of the heat source. The evaporator was a plate with a mesh wick attached to a water-flow pipe. Cold energy transferred from the condenser surface to the evaporator surface only when the temperature of the condenser surface was lower than that of the evaporator surface. We analyzed the unsteady temperature change and heat transfer performance of the flat heat pipe by numerical simulation. The analytical results showed that it was necessary to have two thermal switches to separate the heat energy and cold energy of the changing heat source. Also, it was important to reduce the thermal resistance and heat capacity of the evaporator surface to improve the unsteady heat transfer performance of the heat pipe. Next, we measured the unsteady heat transfer performance of the flat heat pipe experimentally. The experimental results showed that the thermal-switching behavior was observed when the heat generation of the heat source changed every 5 s.


Author(s):  
Chaofan Dong ◽  
Xuanyang Hu ◽  
Yuping Qian ◽  
Changjiang Wang ◽  
Weilin Zhuge ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document