Separation of Phenylarsonic Compounds by Ion Pairing–Reversed Phase–High Performance Liquid Chromatography

Author(s):  
Jafariah Jaafar

Sebatian fenilarsonik digunakan dengan meluas sebagai bahan tambah makanan ternakan bagi membantu proses tumbesaran dan mengawal penyakit di dalam industri ternakan ayam. Satu kaedah dijalankan bagi analisis arsenik di dalam bahan tambah makanan ternakan secara HPLC fasa terbalik–pasangan ion dengan pengesan ultralembayung. Dengan menggunakan turus oktadekilsililsilika, pemisahan sebatian arsenik anion [asid 3–nitro–4–hidroksifenilarsonik (3–NHPAA), asid p–arsanilik (p–ASA) dan asid fenilarsonik (PA)] telah diperoleh menggunakan tetrabutilammonium klorida 5 mM sebagai reagen pasangan ion di dalam fasa bergerak yang mengandungi asid malonik 3 mM dan 5% metanol pada kadar alir 1.4 mL min–1. Pengaruh pH fasa bergerak ke atas pemisahan dikaji dan didapati pH optimum adalah 5.85. Had pengesanan yang diperoleh bagi 3–NHPAA ialah 0.43 ng As. Kata kunci: arsenik; bahan tambah makanan ternakan; HPLC fasa terbalik-pasangan ion Phenylarsonic compounds are extensively used as feed additives to promote growth and to control disease in the poultry industry. A method was conducted that allowed the analysis of arsenic animal feed additives by ion pairing–reversed phase HPLC (IP–RP–HPLC) with a UV detection using an octadecylsilylsilica column. The separation of anionic arsenic compounds [3–nitro–4–hydroxyphenylarsonic acid (3–NHPAA), p–arsanilic acid (p ASA) and phenylarsonic acid (PA)] was accomplished using 5 mM tetrabutylammonium chloride as the ion pairing reagent in aqueous mobile phase containing 3 mM malonic acid and 5% methanol at a flow rate of 1.4 mL min–1. The influence of mobile phase pH on the separation was studied; the optimum pH found was 5.85. The detection limit obtained for 3–NHPAA was 0.43 ng As. Key words: arsenic; animal feed additives; ion pairing-reversed phase-high performance liquid chromatography

1994 ◽  
Vol 59 (3) ◽  
pp. 569-574 ◽  
Author(s):  
Josef Královský ◽  
Marta Kalhousová ◽  
Petr Šlosar

The reversed-phase high-performance liquid chromatography of some selected, industrially important aromatic sulfones has been investigated. The chromatographic behaviour of three groups of aromatic sulfones has been studied. The optimum conditions of separation and UV spectra of the sulfones and some of their hydroxy and benzyloxy derivatives are presented. The dependences of capacity factors vs methanol content in mobile phase are mentioned. The results obtained have been applied to the quantitative analysis of different technical-grade samples and isomer mixtures. For all the separation methods mentioned the concentration ranges of linear calibration curves have been determined.


1977 ◽  
Vol 23 (12) ◽  
pp. 2288-2291 ◽  
Author(s):  
P H Culbreth ◽  
I W Duncan ◽  
C A Burtis

Abstract We used paired-ion high-performance liquid chromatography to determine the 4-nitrophenol content of 4-nitrophenyl phosphate, a substrate for alkaline phosphatase analysis. This was done on a reversed-phase column with a mobile phase of methanol/water, 45/55 by vol, containing 3 ml of tetrabutylammonium phosphate reagent per 200 ml of solvent. At a flow rate of 1 ml/min, 4-nitrophenol was eluted at 9 min and monitored at 404 nm; 4-nitrophenyl phosphate was eluted at 5 min and could be monitored at 311 nm. Samples of 4-nitrophenyl phosphate obtained from several sources contained 0.3 to 7.8 mole of 4-nitrophenol per mole of 4-nitrophenyl phosphate.


Author(s):  
Muhammad Fawad Rasool ◽  
Umbreen Fatima Qureshi ◽  
Nazar Muhammad Ranjha ◽  
Imran Imran ◽  
Mouqadus Un Nisa ◽  
...  

AbstractTh accurate rapid, simple and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of captopril (CAP). Chromatographic separation was accomplished using prepacked ODSI C18 column (250 mm × 4.6 mm with 5 μm particle size) in isocratic mode, with mobile phase consisting of water: acetonitrile (60:40 v/v), pH adjusted to 2.5 by using 85% orthophosphoric acid at a flow rate of 1 mL/min and UV detection was performed at 203 nm. RP-HPLC method used for the analysis of CAP in mobile phase and rabbit plasma was established and validated as per ICH-guidelines. It was carried out on a well-defined chromatographic peak of CAP was established with a retention time of 4.9 min and tailing factor of 1.871. The liquid–liquid extraction method was used for extraction of CAP from the plasma. Excellent linearity (R2 = 0.999) was shown over range 3.125–100 µg/mL with mean percentage recoveries ranges from 97 to 100.6%. Parameters of precision and accuracy of the developed method meet the established criteria. Intra and inter-day precision (% relative standard deviation) study was also performed which was less than 2% which indicate good reproducibility of the method. The limit of detection (LOD) and quantification for the CAP in plasma were 3.10 and 9.13 ng/mL respectively. The method was suitably validated and successfully applied to the determination of CAP in rabbit plasma samples.


Author(s):  
Mannem Durga Babu ◽  
Kesana Surendrababu

Objective: The objective of the study was to develop and validate a novel, specific, precise, and simple reversed-phase high-performance liquid chromatography method for the estimation of guaifenesin present in methocarbamol API and its pharmaceutical dosage forms. Methods: The baseline separation for methocarbamol and guaifenesin was achieved by utilizing a Inertsil ODS C18 (250 mm × 4.6 mm) 5 μm column particle size and an isocratic elution method. The mobile phase contains a mixture of water and acetonitrile in the ratio of 70:30 v/v, respectively. The flow rate of the mobile phase was 1.0 mL/min with a column temperature of 25°C and detection wavelength at 272 nm. The method was validated for a limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and reproducibility with the help of the exhibit and simulated samples. Results: The LOD for guaifenesin was 0.62 μg/mL. The LOQ for guaifenesin was 1.87 μg/mL. The correlation coefficient obtained for impurity was >0.99. The recovery was obtained for impurity was 106.56% at 50%, 95.20% at 100%, and 100.45% at 150%. In tablet analysis, we can found 0.26% (<0.5%). Conclusion: The developed method was validated as per the ICH guidelines with respect to specificity, precision, linearity, accuracy, LOD and quantification, ruggedness, robustness, and solution stability.


2002 ◽  
Vol 65 (4) ◽  
pp. 688-691 ◽  
Author(s):  
P. S. GONG ◽  
S. L. JENG ◽  
Y. F. HSU ◽  
C. C. LIN ◽  
S. Y. LIN

An ion-pairing reversed-phase high-performance liquid chromatography (HPLC) method with diode array detection at 280 nm was developed to determine pyrimethamine concentrations in feed for laying hens. Pyrimethamine was extracted with a mixture of 5% isobutanol and 95% benzene, and the extract was cleaned up on an alumina column. The drug was eluted from an Intersil ODS-3V column (250 by 4.6 mm) with a mixture of 25% acetonitrile and 75% water (vol/vol) containing 0.01 M tetramethylammonium chloride as an ion-pairing agent and adjusted with acetic acid to pH 3.5. The flow rate was 1.0 ml/min. Mean recovery of pyrimethamine from supplemented feeds at concentrations of 2, 4, and 5 μg/g of feed were 100.5, 103.5, and 100.8%, respectively. Precision within a day ranged from 4.3 to 7.0% for the three concentrations, and day-to-day precision was 5.3% for feed supplemented at a concentration of 4 μg/g. No chromatographic interference was detected from other 2,4-diaminopyrimidine compounds or other major drugs used in poultry.