scholarly journals The effects of despeckling filters on pore size measurements in collagen scaffold micro‐CT data

2021 ◽  
Author(s):  
Matthew C Meek ◽  
Serena Best ◽  
Ruth Cameron
Keyword(s):  
Micro Ct ◽  
Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1995
Author(s):  
Mirko Sinico ◽  
Suraj Dinkar Jadhav ◽  
Ann Witvrouw ◽  
Kim Vanmeensel ◽  
Wim Dewulf

Recently, the use of novel CuCr1 surface-modified powder for reliable laser powder-bed fusion (LPBF) manufacturing has been proposed, enabling a broader LPBF processing window and longer powder storage life. Nevertheless, virgin CuCr1 powder is also LPBF processable, on the condition that a high-energy density is employed. In this work, we compare two dense specimens produced from virgin and surface-modified CuCr1 powder. Furthermore, a third sample fabricated from surface-modified powder is characterized to understand an abnormal porosity content initially detected through Archimedes testing. Utilizing high-resolution micro-CT scans, the nature of the defects present in the different samples is revealed. Pores are analyzed in terms of size, morphology and spatial distribution. The micro-CT data reveal that the virgin CuCr1 dense specimen displays keyhole pores plus pit cavities spanning multiple layer thicknesses. On the other hand, the sample fabricated with the surface-modified CuCr1 powder mainly contains small and spherical equi-distributed metallurgical defects. Finally, the CT analysis of the third specimen reveals the presence of a W contamination, favoring lack-of-fusion pores between subsequent LPBF layers. The LPBF melting mode (keyhole or conductive), the properties of the material, and the potential presence of contaminants are connected to the different porosity types and discussed.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Michael Zenzes ◽  
Paul Zaslansky

AbstractMicro-CT provides critical data for musculoskeletal research, yielding three-dimensional datasets containing distributions of mineral density. Using high-resolution scans, we quantified changes in the fine architecture of bone in the spine of young mice. This data is made available as a reference to physiological cancellous bone growth. The scans (n = 19) depict the extensive structural changes typical for female C57BL/6 mice pups, aged 1-, 3-, 7-, 10- and 14-days post-partum, as they attain the mature geometry. We reveal the micro-morphology down to individual trabeculae in the spine that follow phases of mineral-tissue rearrangement in the growing lumbar vertebra on a micrometer length scale. Phantom data is provided to facilitate mineral density calibration. Conventional histomorphometry matched with our micro-CT data on selected samples confirms the validity and accuracy of our 3D scans. The data may thus serve as a reference for modeling normal bone growth and can be used to benchmark other experiments assessing the effects of biomaterials, tissue growth, healing, and regeneration.


SPE Journal ◽  
2021 ◽  
pp. 1-20
Author(s):  
Shouxiang Mark Ma ◽  
Gabriela Singer ◽  
Songhua Chen ◽  
Mahmoud Eid

Summary Typically, smooth solid surfaces of reservoir rocks are assumed in formation evaluation, such as nuclear-magnetic-resonance (NMR) petrophysics and reservoir-wettability characterization through contact-angle measurements. Measuring the degree of surface roughness (R), or smoothness, and evaluating its effects on formation evaluation are topics of much research. In this paper, we primarily focus on details in characterizing solid-surface roughness and its applications in NMR pore-sizeanalysis. R can be measured by contact techniques and noncontact techniques, such as stylus profilometer, atomic-force microscopy, and different kinds of optical measurements. Each technique has different sensitivities, measurement artifacts, resolutions, and field of view (FOV). Intuitively, although a finer resolution measurement provides the closest account of all surface details, the correspondingly small FOV might compromise the representativeness of the measurement, which is particularly challenging for charactering heterogeneous samples such as carbonates. To balance the FOV and measurement representativeness, and to minimize artifacts, laser scanner confocal microscopy (LSCM) is selected in this study. Results for the more than 27 rock samples tested indicate that rocks of similar rock types have similar R-values. Grainy limestones have relatively higher R-values compared with dolostones, consistent with the dolostone’s crystallization surface features. Muddy limestones have smoother surfaces, resulting in the lowest R-values among the rocks studied. For sandstones, R varies with clay types and content. For rocks containing two distinct minerals, two R-values are observed from the R profiles, which for these rock types justifies the use of two NMR surface relaxivity (ρ2) parameters for determining the pore-size distribution (PSD) from the NMR T2distribution. The novelty here is the integration of LSCM and NMR to obtain an NMR PSD relevant for permeability, capillary pressure, and other petrophysical parameters. Typically, ρ2 is calibrated using the total surface area from Brunauer-Emmett-Teller (BET; Brunauer et al. 1938) gas adsorption, but this underestimates the NMR pore size because of surface-roughness effects. In our novel approach, we use R measured from LSCM to correct ρ2 for surface-roughness effects, and thereby obtain the NMR pore size more relevant for permeability and other petrophysical parameters. We then compare the roughness-corrected NMR PSD against pore size from microcomputed tomography (micro-CT) scanning (which is roughness independent). The good agreement between roughness-corrected NMR and micro-CT pore sizes in the micropore region validates our new technique, and highlights the importance of surface-roughness characterization in NMR petrophysics.


2014 ◽  
Author(s):  
I Seetho ◽  
K Morales ◽  
W White ◽  
H Martz
Keyword(s):  
Micro Ct ◽  

Author(s):  
Lambros S. Athanasiou ◽  
Dimitrios I. Fotiadis ◽  
Lampros K. Michalis
Keyword(s):  
Micro Ct ◽  

Author(s):  
E Ghassemieh

Porous poly(l-lactic acid) (PLA) scaffolds of 85 per cent and 90 per cent porosity are prepared using polymer sintering and porogen leaching method. Different weight fractions of 10 per cent, 30 per cent, and 50 per cent of hydroxyapatite (HA) are added to the PLA to control the acidity and degradation rate. The three-dimensional (3D) morphology and surface porosity are tested using micro-computer tomography (micro-CT), optical microscopy, and scanning electron microscopy (SEM). Results indicate that the surface porosity does not change on the addition of HA. The micro-CT examinations show a slight decrease in the pore size and increase in the wall thickness accompanied by reduced anisotropy for the scaffolds containing HA. Scanning electron micrographs show detectable interconnected pores for the scaffold with pure PLA. Addition of the HA results in agglomeration of the HA particles and reduced leaching of the porogen. Compression tests of the scaffold identify three stages in the stress—strain curve. The addition of HA results in a reduction in the modulus of the scaffold at the first stage of elastic bending of the wall, but this is reversed for the second and third stages of collapse of the wall and densification in the compression tests. In the scaffolds with 85 per cent porosity, the addition of a high percentage of HA could result in 70 per cent decrease in stiffness in the first stage, 200 per cent increase in stiffness in the second stage, and 20 per cent increase in stiffness in the third stage. The results of these tests are compared with the Gibson cellular material model that is proposed for prediction of the behaviour of cellular material under compression. The pH and molecular weight changes are tracked for the scaffolds within a period of 35 days. The addition of HA keeps the pH in the alkaline region, which results in higher rate of degradation at an early period of observation, followed by a reduced rate of degradation later in the process. The final molecular weight is higher for the scaffolds with HA than for scaffolds of pure PLA. The manufactured scaffolds offer acceptable properties in terms of the pore size range and interconnectivity of the pores and porosity for non-load-bearing bone graft substitute; however, improvement to the mixing of the phases of PLA and HA is required to achieve better integrity of the composite scaffolds.


Bone ◽  
2004 ◽  
Vol 34 (1) ◽  
pp. 163-169 ◽  
Author(s):  
J.H Waarsing ◽  
J.S Day ◽  
J.C van der Linden ◽  
A.G Ederveen ◽  
C Spanjers ◽  
...  
Keyword(s):  
Micro Ct ◽  

2010 ◽  
Vol 14 (6) ◽  
pp. 723-737 ◽  
Author(s):  
Martin Baiker ◽  
Julien Milles ◽  
Jouke Dijkstra ◽  
Tobias D. Henning ◽  
Axel W. Weber ◽  
...  

2009 ◽  
Vol 15 (S2) ◽  
pp. 386-387
Author(s):  
M Boone ◽  
A Almeida ◽  
Y De Witte ◽  
M Dierick ◽  
JP Remon ◽  
...  

Extended abstract of a paper presented at Microscopy and Microanalysis 2009 in Richmond, Virginia, USA, July 26 – July 30, 2009


Sign in / Sign up

Export Citation Format

Share Document