Effects of Additional Acid Etching on the Dentin Bond Strengths of One-Step Self-Etch Adhesives Applied to Primary Teeth

2016 ◽  
Vol 29 (2) ◽  
pp. 110-117 ◽  
Author(s):  
Yuhyun Kim ◽  
Shin Kim ◽  
Taesung Jeong ◽  
Sung-Ae Son ◽  
Jiyeon Kim
2006 ◽  
Vol 31 (1) ◽  
pp. 25-32 ◽  
Author(s):  
M. Toledano ◽  
R. Osorio ◽  
A. Albaladejo ◽  
F. S. Aguilera ◽  
F. R. Tay ◽  
...  

Clinical Relevance Resin-dentin bonds, which may have an influence on the long-term success of restorations, are prone to deterioration after cyclic loading. The tested one-step self-etching system (Etch&Prime 3.0) provided the least reliable dentin adhesion. After acid etching of dentin, alcohol/based adhesives performed better than those containing acetone as solvent.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Babacar Faye ◽  
Mouhamed Sarr ◽  
Khaly Bane ◽  
Adjaratou Wakha Aidara ◽  
Seydina Ousmane Niang ◽  
...  

This study evaluated the one-year clinical performance of a one-step, self-etch adhesive (Optibond All-in-One, Kerr, CA, USA) combined with a composite (Herculite XRV Ultra, Kerr Hawe, CA, USA) to restore NCCLs with or without prior acid etching. Restorations performed by the same practitioner were evaluated at baseline and after 3, 6, and 12 months using modified USPHS criteria. At 6 months, the recall rate was 100%. The retention rate was 84.2% for restorations with prior acid etching, but statistically significant differences were observed between baseline and 6 months. Without acid etching, the retention rate was 77%, and no statistically significant difference was noted between 3 and 6 months. Marginal integrity (93.7% with and 87.7% without acid etching) and discoloration (95.3% with and 92.9% without acid etching) were scored as Alpha or Bravo, with better results after acid etching. After one year, the recall rate was 58.06%. Loss of pulp vitality, postoperative sensitivity, or secondary caries were not observed. After one year retention rate was of 90.6% and 76.9% with and without acid conditioning. Optibond All-in-One performs at a satisfactory clinical performance level for restoration of NCCLs after 12 months especially after acid etching.


10.2341/08-58 ◽  
2009 ◽  
Vol 34 (2) ◽  
pp. 181-191 ◽  
Author(s):  
A. Reis ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
A. M. Andrade ◽  
...  

Clinical Relevance The improvement of resin-enamel bond strengths after using Si-C paper and diamond burs for enamel preparation is material dependent. No degradation of enamel bond strength could be observed for any one-step self-etch adhesive system after 12 months of water storage.


10.2341/08-26 ◽  
2008 ◽  
Vol 33 (6) ◽  
pp. 702-709 ◽  
Author(s):  
M. Ikeda ◽  
K. Tsubota ◽  
T. Takamizawa ◽  
T. Yoshida ◽  
M. Miyazaki ◽  
...  

Clinical Relevance To achieve optimum bond strengths, acid etching of dentin prior to the application of single-step self-etch adhesive systems should be avoided.


2003 ◽  
Vol 11 (3) ◽  
pp. 223-228 ◽  
Author(s):  
Ninoshka Uceda-Gómez ◽  
Alessandra Reis ◽  
Marcela Rocha de Oliveira Carrilho ◽  
Alessandro Dourado Loguercio ◽  
Leonardo Eloy Rodriguez Filho

The objective of this study was to evaluate the bond strength to superficial (SU) and deep (D) dentin, accessed via apical (DA) or occlusal (DO), using One-Step adhesive system applied according to the manufacturer's instructions (C) or following deproteinization with 10% sodium hypochlorite (H) for 60s, after acid etching. Three sound extracted human molars were prepared for each experimental condition. Restorations were performed using Z100 in 2mm increments, each one being light-cured for 40s. Teeth were longitudinally sectioned to obtain stick-shaped specimens with a cross-sectional area of 0.8mm², which were submitted to bond strength test (0.6mm/min). Results obtained after statistical analysis using a two-way ANOVA (substrate vs. surface treatment) and Tukey's test were: SU (35.4 ± 12.3), DO (26.5 ± 8.5), DA (26.1 ± 10.2) following conventional surface treatment, and SU (28.82 ± 12.7), DO (24.3 ± 8.3) and DA (23.5 ± 8.5), after surface treatment using sodium hypochlorite. The interaction of the factors was not significant (p>0.05). However, the main factors were significant (p<0.05). Mean bond strength values in superficial dentin were statistically superior to deep dentin (p<0.05), although no statistically significant difference was observed between the two via of access to deep dentin (SU>DO=DA). The conventional surface treatment resulted in higher bond strength values than the sodium hypochlorite treatment (p<0.05). It was concluded: 1) bond strength values were higher in superficial dentin, 2) no difference was found between the two deep substrate preparations, and 3) the application of sodium hypochlorite following dentin acid etching may reduce bond strengths.


2012 ◽  
Vol 30 (4) ◽  
pp. 214-221 ◽  
Author(s):  
Gulsah E Akin ◽  
Seyda Herguner-Siso ◽  
Mutlu Ozcan ◽  
Ozden Ozel-Bektas ◽  
Hakan Akin

10.2341/07-63 ◽  
2008 ◽  
Vol 33 (2) ◽  
pp. 155-162 ◽  
Author(s):  
A-K. Lührs ◽  
S. Guhr ◽  
R. Schilke ◽  
L. Borchers ◽  
W. Geurtsen ◽  
...  

Clinical Relevance When using self-etch adhesives to bond composite materials to enamel, there is concern about the ability to achieve bond strengths comparable to approved etch-and-rinse systems. An additional phosphoric acid etching can improve the shear bond strength of self-etch adhesives to enamel.