The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog

2013 ◽  
Vol 25 (11) ◽  
pp. 1213-1221 ◽  
Author(s):  
Carolina Manresa ◽  
Manel Bosch ◽  
José J. Echeverría
2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Warwick J. Duncan ◽  
Min-Ho Lee ◽  
Tae-Sung Bae ◽  
Sook-Jeong Lee ◽  
Jennifer Gay ◽  
...  

Spark discharge anodic oxidation forms porous TiO2films on titanium implant surfaces. This increases surface roughness and concentration of calcium and phosphate ions and may enhance early osseointegration. To test this, forty 3.75 mm × 13 mm titanium implants (Megagen, Korea) were placed into healed mandibular postextraction ridges of 10 sheep. There were 10 implants per group: RBM surface (control), RBM + anodised, RBM + anodised + fluoride, and titanium alloy + anodised surface. Resonant frequency analysis (RFA) was measured in implant stability quotient (ISQ) at surgery and at sacrifice after 1-month unloaded healing. Mean bone-implant contact (% BIC) was measured in undemineralised ground sections for the best three consecutive threads. One of 40 implants showed evidence of failure. RFA differed between groups at surgery but not after 1 month. RFA values increased nonsignificantly for all implants after 1 month, except for controls. There was a marked difference in BIC after 1-month healing, with higher values for alloy implants, followed by anodised + fluoride and anodised implants. Anodisation increased early osseointegration of rough-surfaced implants by 50–80%. RFA testing lacked sufficient resolution to detect this improvement. Whether this gain in early bone-implant contact is clinically significant is the subject of future experiments.


2012 ◽  
Vol 38 (1) ◽  
pp. 3-10 ◽  
Author(s):  
Mansour Rismanchian ◽  
Bijan Movahedian Attar ◽  
Sayed Mohammad Razavi ◽  
Ali Nasir Shamsabad ◽  
Majid Rezaei

The endeavors to shorten implant treatment time have led to the concept of immediate loading. This research was designed to compare the immediate loading and the 2-staged methods on implant placement from a clinical, histological, and histomorphometric standpoint. Three months postextraction of 12 premolars of 3 dogs, 12 implants were inserted. Bone-implant contact (BIC), implant stability quotient (ISQ), the bone type in a 2-mm periphery around the implant, and the marginal bone loss (MBL) were recorded for unloaded implants (n  =  6) and immediately loaded ones (n  =  6). BIC, ISQ, MBL in the mesial, and the bone types around the implants were not significantly different in the 2 groups. The distal MBL was higher in the immediately loaded group. Immediate loading does not appear to be perilous for osseointegration, BIC, or new bone type around implants.


2021 ◽  
Author(s):  
Rafael Coutinho Mello-Machado ◽  
Suelen Cristina Sartoretto ◽  
Jose Mauro Granjeiro ◽  
José Albuquerque Calasans-Maia ◽  
Marcelo Jose Guedes Pinheiro Uzeda ◽  
...  

Abstract This study aimed to investigate in vivo the hypothesis that the osseodensification technique, through a wider osteotomy, produce healing chambers at the implant-bone interface with no impact on primary stability osseointegration in low-density bone. Twenty implants (3.5 x 10 mm) presenting nanohydroxyapatite (nHA) surface were inserted in the ilium of ten sheep, after preparation of a 2.7-mm wide implant bed with conventional subtractive drilling (SCD) or a 3.8-mm wide implant bed with an osseodensification bur system (OBS) (n = 5/group/period). The final insertion torque (IT) and implant stability quotient (ISQ) evaluated the primary implant stability. After 14 and 28 days, the bone samples containing the implants were processed for histological and histomorphometric evaluation of bone implant contact (BIC) and bone area fraction occupancy (BAFO). No significant differences occurred between the implant bed preparations regarding IT and ISQ (P > 0.05). Histological analysis showed bone remodeling, and bone growth in all samples with no inflammatory infiltrate. BIC values were higher for SCD after 14 and 28 days (p < 0.05), however BAFO values were similar on both groups (p > 0.05). It was possible to conclude that the osseodensification technique allowed a wider implant bed preparation with no prejudice on primary stability and bone remodeling.


2017 ◽  
Vol 2017 ◽  
pp. 1-10
Author(s):  
Hsiang-Ho Chen ◽  
Wei-Yi Lai ◽  
Tze-Jian Chee ◽  
Ya-Hui Chan ◽  
Sheng-Wei Feng

The aim of this study was to monitor the changes of viscoelastic properties at bone-implant interface via resonance frequency analysis (RFA) and the Periotest device during the healing process in an experimental rabbit model. Twenty-four dental implants were inserted into the femoral condyles of rabbits. The animals were sacrificed immediately after implant installation or on day 14, 28, or 56 after surgery. Viscoelastic properties at bone-implant interface were evaluated by measuring the implant stability quotient (ISQ) using RFA and by measuring the Periotest values (PTVs) using the Periotest device. The bone/implant specimens were evaluated histopathologically and histomorphometrically to determine the degree of osseointegration (BIC%). The BIC% values at different time points were then compared with the corresponding ISQ values and PTVs. The mean ISQ value increased gradually and reached 81±1.7 on day 56, whereas the mean PTV decreased over time, finally reaching −0.7±0.5 on day 56. Significant correlations were found between ISQ and BIC% (r=0.701, p<0.001), PTV and BIC% (r=-0.637, p<0.05), and ISQ and PTV (r=-0.68, p<0.05). These results show that there is a positive correlation between implant stability parameters and peri-implant-bone healing, indicating that the RFA and Periotest are useful for measuring changes of viscoelastic properties at bone-implant interface and are reliable for indirectly predicting the degree of osseointegration.


Author(s):  
VARSHA PALLED ◽  
DR. JITENDRA RAO ◽  
DR. RAGHUWAR DAYAL SINGH ◽  
DR. SHUCHI TRIPATHI ◽  
DR. KALPANA SINGH ◽  
...  

The purpose of this study was to evaluate whether Low-Level Laser Therapy (LLLT) improves the healing of the implant surgical site with clinical and biochemical parameters.Thirty patients with an edentulous space spanning a single tooth were selected. The patients were randomly allocated to two groups - the control group and the test group. The test group received laser energy at a power of 2J/cm 2 with a total of 4-6J energy over each implant. Clinical parameters (Implant Stability Quotient, probing index, modified sulcus bleeding index)and osteoprotegerin (OPG) were assessed at baseline and follow-up intervals (2 weeks, 6 weeks, and 3 months).The test group showed significantly higher implant stability quotient compared to thecontrol group at 2 weeks(57.93±3.95 and 35.67±3.08; p&lt;0.01) and 3months(58.86±3.75 and 67.06±3.78; p&lt;0.01). A significant rise in OPG levels of the test group(686.30±125.36pg/ml at baseline and 784.25±108.30pg/ml at 3months;p&lt;0.01) was seen contrary to significant decline in the control group (839.50±249.08pg/ml at baseline,415.30±78.39pg/ml at 3months;p&lt;0.01). Within the limitations of the study, the study suggests that the healing of peri-implant hard and soft tissues may be enhanced with the use of LLLT as an explicit modality during the post-operative period.


2019 ◽  
Vol 45 (4) ◽  
pp. 259-266
Author(s):  
Claudio Stacchi ◽  
Matteo De Biasi ◽  
Lucio Torelli ◽  
Massimo Robiony ◽  
Roberto Di Lenarda ◽  
...  

The primary objective of the present in vitro study was to evaluate the influence of implant site preparation technique (drills vs ultrasonic instrumentation) on the primary stability of short dental implants with two different designs inserted in simulated low-quality cancellous bone. Eighty implant sites were prepared in custom-made solid rigid polyurethane blocks with two different low cancellous bone densities (5 or 15 pounds per cubic foot [PCF]), equally distributed between piezoelectric (Surgysonic Moto, Esacrom, Italy) and conventional drilling techniques. Two short implant systems (Prama and Syra, Sweden & Martina) were tested by inserting 40 fixtures of each system (both 6.0 mm length and 5.0 mm diameter), divided in the four subgroups (drills/5 PCF density; drills/15 PCF density; piezo/5 PCF density; piezo/15 PCF density). Insertion torque (Ncm), implant stability quotient values, removal torque (Ncm), and surgical time were recorded. Data were analyzed by 3-way ANOVA and Scheffé's test (α = 0.05). With slight variations among the considered dependent variables, overall high primary implant stability was observed across all subgroups. Piezoelectric instrumentation allowed for comparable or slightly superior primary stability in comparison with the drilling procedures in both implant systems. The Prama implants group showed the highest mean reverse torque and Syra implants the highest implant stability quotient values. Piezoelectric implant site preparation took prolonged operative time compared to conventional preparation with drills; among the drilling procedures, Syra system required fewer surgical steps and shorter operative time.


2018 ◽  
Vol 29 ◽  
pp. 297-297
Author(s):  
Alexandre Campos Montenegro ◽  
Mario Vieira Neto ◽  
Gonçalo Pimentel Neto ◽  
Silvana Pizzini Montenegro ◽  
Kamila Temponi ◽  
...  

2017 ◽  
Vol 43 (2) ◽  
pp. 131-138 ◽  
Author(s):  
Yen-Ting Lin ◽  
Adrienne Hong ◽  
Ying-Chin Peng ◽  
Hsiang-Hsi Hong

Clinical decisions regarding the stability and osseointegration of mandibular implants positioned using the bone expansion techniques are conflicting and limited. The objective was to evaluate the stability of implants placed using 2 surgical techniques, selected according to the initial width of the mandibular posterior edentulous ridge, with D3 bone density, during a 12-week period. Fifty-eight implants in 33 patients were evaluated. Thirty-two implants in 24 patients were positioned using the osteotome expansion technique, and 26 fixtures in 17 patients were installed using the conventional drilling technique. The implant stability quotient values were recorded at weeks 0, 1, 2, 3, 4, 6, 8, 10, and 12 postsurgery and evaluated using analysis of variance, independent, and paired t tests. Calibrated according to the stability reading of a 3.3-mm diameter implant, the osteotome expansion group was associated with a lower bone density than the conventional group (64.96 ± 6.25 vs 68.98 ± 5.06, P = .011). The osteotome expansion group achieved a comparable primary stability (ISQb-0, P = .124) and greater increases in secondary stability (ISQb-12, P = .07) than did the conventional technique. A D3 quality ridge with mild horizontal deficiency is expandable by using the osteotome expansion technique. Although the 2 groups presented similar implant stability quotient readings during the study period, the osteotome expansion technique showed significant improvement in secondary stability. The healing patterns for these techniques are therefore inconsistent.


Sign in / Sign up

Export Citation Format

Share Document