Report on Proposed Standard P690 for the Design and Installation of Cable Systems for Class 1E Circuits for Nuclear Power Generating Stations

1981 ◽  
Vol PAS-100 (12) ◽  
pp. 4774-4775
Author(s):  
Power Committee
Keyword(s):  
Author(s):  
Leonard S. Fifield ◽  
Robert Duckworth ◽  
Samuel W. Glass

Nuclear power plants contain hundreds of kilometers of electrical cables including cables used for power, for instrumentation, and for control. It is essential that safety-related cable systems continue to perform following a design-basis event. Wholesale replacement of electrical cables in existing plants facing licensing period renewal may be both impractical and cost-prohibitive. It is therefore important to understand the long term aging of cable materials to have confidence that aged cables will perform when needed. It is equally important in support of cable aging management to develop methods to evaluate the health of installed cables and inform selective cable replacement decisions. The most common insulation materials for electrical cables in nuclear power plants are cross-linked polyethylene and ethylene-propylene rubber. The mechanical properties of these materials degrade over time in the presence of environmental stresses including heat, gamma irradiation, and moisture. Mechanical degradation of cable insulation beyond a certain threshold is unacceptable because it can lead to insulation cracking, exposure of energized conductors, arcing and burning or loss of the ability of the cable system to function during a design-basis accident. While thermal-, radiation-, and moisture-related degradation of polymer insulation materials has been extensively studied over the last few decades, questions remain regarding the long term performance of cable materials in nuclear plant-specific environments. Identified knowledge gaps include an understanding of the temperature-dependence of activation energies for thermal damage and an understanding of the synergistic effects of radiation and thermal stress on polymer degradation. Many of the outstanding questions in the aging behavior of cable materials relate to the necessity of predicting long-term field degradation using accelerated aging results from the laboratory. Materials degrade faster under more extreme conditions, but extension of behavior to long term degradation under more mild conditions, such as those experienced by most installed cables in nuclear power plants, is complicated by the fact that different degradation mechanisms may be involved in extreme and mild scenarios. The discrepancy in predicted results from short term, more extreme exposure and actual results from longer term, more mild exposures can be counter intuitive. For instance, due to the attenuation of oxidation penetration in material samples rapidly aged through exposure to high temperatures, the bulk of the samples may be artificially protected from thermal aging. In another example, simultaneous exposure of cable insulation material to heat and radiation may actually lead to less damage at higher temperatures than may be observed at lower temperatures. The Light Water Reactor Sustainability program of the United States (US) Department of Energy (DOE) Office of Nuclear Energy is funding research to increase the predictive understanding of electrical cable material aging and degradation in existing nuclear power plants in support of continued safe operation of plants beyond their initial license periods. This research includes the evaluation and development of methods to assess installed cable condition.


Polymers ◽  
2021 ◽  
Vol 13 (18) ◽  
pp. 3033
Author(s):  
Ramy S. A. Afia ◽  
Ehtasham Mustafa ◽  
Zoltán Ádám Tamus

Low-voltage cable systems in nuclear power plants are key components that have a crucial role in the safe operation of nuclear facilities. Thus, the aging management of cable systems is of utmost importance as they cannot easily or economically be replaced or upgraded. Therefore, there is a continuous need to develop reliable non-destructive condition monitoring techniques, mostly based on the measurement of the dielectric properties of cable insulation. This paper introduces the changing of dielectric and mechanical properties of XLPE insulated and CSPE jacketed unshielded low-voltage nuclear power plant power cable in case of simultaneous mechanical and radiation aging. The cable samples were bent and exposed to 400 kGy gamma irradiation with a 0.5 kGy/hr dose rate. Dielectric response (real and imaginary permittivity) in the 0.1 Hz−1 kHz frequency range, extended voltage response (EVR), and the Shore D hardness test techniques were measured to track aging. The electrical and mechanical parameters have increased monotonically with aging, except the imaginary permittivity, which increased only at frequencies higher than 10 Hz. Furthermore, different quantities were deducted based on the frequency and permittivity data. The electrical parameters and deducted quantities correlation with aging and mechanical parameters were investigated. Since the deducted quantities and the electrical parameters are strongly correlated with absorbed dose and mechanical properties, the electrical measurements can be applied as a non-destructive aging indicator for XLPE/CSPE unshielded low-voltage nuclear power cables.


Author(s):  
John D. Rubio

The degradation of steam generator tubing at nuclear power plants has become an important problem for the electric utilities generating nuclear power. The material used for the tubing, Inconel 600, has been found to be succeptible to intergranular attack (IGA). IGA is the selective dissolution of material along its grain boundaries. The author believes that the sensitivity of Inconel 600 to IGA can be minimized by homogenizing the near-surface region using ion implantation. The collisions between the implanted ions and the atoms in the grain boundary region would displace the atoms and thus effectively smear the grain boundary.To determine the validity of this hypothesis, an Inconel 600 sample was implanted with 100kV N2+ ions to a dose of 1x1016 ions/cm2 and electrolytically etched in a 5% Nital solution at 5V for 20 seconds. The etched sample was then examined using a JEOL JSM25S scanning electron microscope.


Sign in / Sign up

Export Citation Format

Share Document