CMOS high-speed, high-precision timing generator for 4.266-gbps memory test system

Author(s):  
M. Suda ◽  
K. Yamamoto ◽  
T. Okayasu ◽  
S. Kantake ◽  
S. Sudou ◽  
...  
2015 ◽  
Vol 727-728 ◽  
pp. 761-764
Author(s):  
Xin Zhang ◽  
Ji Long Zhao ◽  
Qing Liang Zeng

For the performance testing demands of roadheader hydraulic components, a hydraulic system of multi-interface and high-precision sensors is built and the signal acquisition and processing system based on PLC and data acquisition card high speed acquisition module is established. A software system based on LabWindows/CVI is developed. High precision, reliability, stable and functional test system is built by using precise sensor technology, electro-hydraulic proportional control technology and automation instrument technology, and then the pump and motor performance tests is completed. The system can simulate the actual working conditions of the pump and motor, making the test results more accurate and credible.


2010 ◽  
Vol 28 (1) ◽  
pp. 104-110 ◽  
Author(s):  
Sang-Hoon Lee ◽  
Soohaeng Cho ◽  
Ki-Jae Song ◽  
Eon-Jo Byun ◽  
SungHo Joo ◽  
...  

Author(s):  
Ilwoo Jung ◽  
Byoungdeok Choi ◽  
Bonggu Sung ◽  
Daejung Kim ◽  
Ilgweon Kim ◽  
...  

Abstract Body effect is the key characteristic of DRAM cell transistor. Conventional method uses a TEG structure for body effect measurement. But this measurement is not accurate, because TEG structure has only several transistors and it is located outside of the DRAM die. This paper suggests a viable method for measuring DRAM cell transistor body effect. It uses a memory test system for fast, massive, nondestructive measurement. Newly developed method can measure 100,000 DRAM cell body effects in two minute, without sample damage. The test gives one median value and 100,000 individual values of body effects. Median value of measured body effects is equal to the TEG body effect. An individual DRAM cell body effect has a correlation with the fin height.


Machines ◽  
2020 ◽  
Vol 9 (1) ◽  
pp. 1
Author(s):  
Jing Wang ◽  
Zhihua Wan ◽  
Zhurong Dong ◽  
Zhengguo Li

The harmonic reducer, with its advantages of high precision, low noise, light weight, and high speed ratio, has been widely used in aerospace solar wing deployment mechanisms, antenna pointing mechanisms, robot joints, and other precision transmission fields. Accurately predicting the performance of the harmonic reducer under various application conditions is of great significance to the high reliability and long life of the harmonic reducer. In this paper, a set of automatic harmonic reducer performance test systems is designed. By using the CANOpen bus interface to control the servo motor as the drive motor, through accurately controlling the motor speed and rotation angle, collecting the angle, torque, and current in real time, the life cycle test of space harmonic reducer was carried out in high vacuum and low temperature environment on the ground. Then, the collected data were automatically analyzed and calculated. The test data of the transmission accuracy, backlash, and transmission efficiency of the space harmonic reducer were obtained. It is proven by experiments that the performance data of the harmonic reducer in space work can be more accurately obtained by using the test system mentioned in this paper, which is convenient for further research on related lubricating materials.


2021 ◽  
pp. 002029402110022
Author(s):  
Xiaohua Zhou ◽  
Jianbin Zheng ◽  
Xiaoming Wang ◽  
Wenda Niu ◽  
Tongjian Guo

High-speed scanning is a huge challenge to the motion control of step-scanning gene sequencing stage. The stage should achieve high-precision position stability with minimal settling time for each step. The existing step-scanning scheme usually bases on fixed-step motion control, which has limited means to reduce the time cost of approaching the desired position and keeping high-precision position stability. In this work, we focus on shortening the settling time of stepping motion and propose a novel variable step control method to increase the scanning speed of gene sequencing stage. Specifically, the variable step control stabilizes the stage at any position in a steady-state interval rather than the desired position on each step, so that reduces the settling time. The resulting step-length error is compensated in the next acceleration and deceleration process of stepping to avoid the accumulation of errors. We explicitly described the working process of the step-scanning gene sequencer and designed the PID control structure used in the variable step control for the gene sequencing stage. The simulation was performed to check the performance and stability of the variable step control. Under the conditions of the variable step control where the IMA6000 gene sequencer prototype was evaluated extensively. The experimental results show that the real gene sequencer can step 1.54 mm in 50 ms period, and maintain a high-precision stable state less than 30 nm standard deviation in the following 10 ms period. The proposed method performs well on the gene sequencing stage.


2007 ◽  
Vol 6 (3) ◽  
pp. 255-266 ◽  
Author(s):  
Anthony M. Choo ◽  
Jie Liu ◽  
Clarrie K. Lam ◽  
Marcel Dvorak ◽  
Wolfram Tetzlaff ◽  
...  

Object In experimental models of spinal cord injury (SCI) researchers have typically focused on contusion and transection injuries. Clinically, however, other injury mechanisms such as fracture–dislocation and distraction also frequently occur. The objective of the present study was to compare the primary damage in three clinically relevant animal models of SCI. Methods Contusion, fracture–dislocation, and flexion–distraction animal models of SCI were developed. To visualize traumatic increases in cellular membrane permeability, fluorescein–dextran was infused into the cerebrospi-nal fluid prior to injury. High-speed injuries (approaching 100 cm/second) were produced in the cervical spine of deeply anesthetized Sprague–Dawley rats (28 SCI and eight sham treated) with a novel multimechanism SCI test system. The animals were killed immediately thereafter so that the authors could characterize the primary injury in the gray and white matter. Sections stained with H & E showed that contusion and dislocation injuries resulted in similar central damage to the gray matter vasculature whereas no overt hemorrhage was detected following distraction. Contusion resulted in membrane disruption of neuronal somata and axons localized within 1 mm of the lesion epicenter. In contrast, membrane compromise in the dislocation and distraction models was observed to extend rostrally up to 5 mm, particularly in the ventral and lateral white matter tracts. Conclusions Given the pivotal nature of hemorrhagic necrosis and plasma membrane compromise in the initiation of downstream SCI pathomechanisms, the aforementioned differences suggest the presence of mechanism-specific injury regions, which may alter future clinical treatment paradigms.


Cytotherapy ◽  
2021 ◽  
Vol 23 (5) ◽  
pp. S97
Author(s):  
J. Bell ◽  
Y. Huang ◽  
S. Yung ◽  
H. Qazi ◽  
C. Hernandez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document