Novel Fault Ride-Through Scheme and Control Strategy for Doubly Fed Induction Generator-Based Wind Turbine

2015 ◽  
Vol 30 (2) ◽  
pp. 635-645 ◽  
Author(s):  
Po-Hsu Huang ◽  
Mohamed Shawky El Moursi ◽  
Suud Ademnur Hasen
2014 ◽  
Vol 707 ◽  
pp. 329-332
Author(s):  
Li Ling Sun ◽  
Dan Fang

As the number of doubly fed induction generator (DFIG)- based wind-turbine systems continues to increase, wind turbines are required to provide Low Voltage Ride-Through (LVRT) capability, especially under the condition of grid voltage dips. This paper, depending on the operating characteristics of doubly-fed induction generator during grid faults ,deals with a protection and control strategy on rotor-side converter (RSC) to enhance the low voltage ride through capability of a wind turbine driven doubly fed induction generator (DFIG). The simulation and experiment studies demonstrate the correctness of the developed model and the effectiveness of the control strategy for DFIG-based wind-turbine systems under such adverse grid conditions.


2018 ◽  
Vol 8 (11) ◽  
pp. 2059 ◽  
Author(s):  
Seyed Naderi ◽  
Pooya Davari ◽  
Dao Zhou ◽  
Michael Negnevitsky ◽  
Frede Blaabjerg

The doubly-fed induction generator has significant features compared to the fixed speed wind turbine, which has popularised its application in power systems. Due to partial rated back-to-back converters in the doubly-fed induction generator, fault ride-through capability improvement is one of the important subjects in relation to new grid code requirements. To enhance the fault ride-through capability of the doubly-fed induction generator, many studies have been carried out. Fault current limiting devices are one of the techniques utilised to limit the current level and protect the switches, of the back-to-back converter, from over-current damage. In this paper, a review is carried out based on the fault current limiting characteristic of fault current limiting devices, utilised in the doubly-fed induction generator. Accordingly, fault current limiters and series dynamic braking resistors are mainly considered. Operation of all configurations, including their advantages and disadvantages, is explained. Impedance type and the location of the fault current limiting devices are two important factors, which significantly affect the behaviour of the doubly-fed induction generator in the fault condition. These two factors are studied by way of simulation, basically, and their effects on the key parameters of the doubly-fed induction generator are investigated. Finally, future works, in respect to the application of the fault current limiter for the improvement of the fault ride-through of the doubly-fed induction generator, have also been discussed in the conclusion section.


2017 ◽  
Vol 7 (2) ◽  
pp. 77-91
Author(s):  
Merabet Leila ◽  
Mekki Mounira ◽  
Ourici Amel ◽  
Saad Salah

This paper describes the modelling and control system of a wind turbine, using a doubly fed induction generator. This configuration makes the wind turbine suitable for variable speed wind energy application. The power captured by the wind turbine is converted into electrical power by the induction generator, and it is transmitted to the grid by the stator and the rotor windings. The control system generates voltage command signals for rotor converter and grid converter, respectively, in order to control the power of the wind turbine. Reactive power exchanged with the network through the converters is set to 0 VAr. The control strategy has been developed using MATLAB/Simulink. The simulation results are presented and discussed in the conclusions. Keywords: Wind energy, doubly fed induction generator, grid power, modelling, control.


Author(s):  
V. Mohana Kalyani ◽  
J. Preetha Roselyn ◽  
C. Nithya ◽  
D. Devaraj

Due to increasing demand in power, the integration of renewable sources like wind generation into power system is gaining much importance nowadays. The heavy penetration of wind power into the power system leads to many integration issues mainly due to the intermittent nature of the wind and the desirability for variable speed operation of the generators. As the wind power generation depends on the wind speed, its integration into the grid has noticeable influence on the system stability and becomes an important issue especially when a fault occurs on the grid. The protective disconnection of a large amount of wind power during a fault will be an unacceptable consequence and threatens the power system stability. With the increasing use of wind turbines employing Doubly Fed Induction Generator (DFIG) technology, it becomes a necessity to investigate their behavior during grid faults and support them with fault ride through capability. This paper presents the modeling and simulation of a doubly fed induction generator according to grid code compatibility driven by a wind turbine connected to the grid. This paper analyses the voltage sag due to a three-phase fault in the wind connected grid. A control strategy including a crowbar circuit has been developed in MATLAB/SIMULINK to bypass the rotor over currents during grid fault to enhance the fault ride through capability and to maintain system stability. Simulation results show the effectiveness of the proposed control strategies in DFIG based grid connected wind turbine system.