Operation Logging System using the database for the synchrotron radiation beam lines at the Photon Factory

Author(s):  
N. Kanaya ◽  
S. Asaoka ◽  
H. Maezawa
1989 ◽  
Vol 36 (4) ◽  
pp. 1391-1395 ◽  
Author(s):  
N. Kanaya ◽  
S. Sato ◽  
S. Asaoka ◽  
K. Nakajima ◽  
S. Hayashi ◽  
...  

1998 ◽  
Vol 5 (3) ◽  
pp. 842-844
Author(s):  
Toshiyuki Mitsuhashi ◽  
Sigenori Hiramatsu ◽  
Naoya Takeuchi ◽  
Masahide Itoh ◽  
Toyohiko Yatagai

Recent activities at optical laboratories 1 and 2 at the Photon Factory are presented. The activities are (i) construction of optical laboratory 1, (ii) reconstruction of optical laboratory 2, (iii) construction of a visible synchrotron radiation beam extraction mirror made of beryllium, (iv) small-beam-profile measurement by means of the image restoration method, (v) application of the adaptive optical system for correction of distorted wavefronts caused by deformation of the extraction mirror, (vi) construction of a synchrotron radiation interferometer for investigation of the spatial coherency of the visible synchrotron radiation beam and its application to the measurement of vertical beam profile and size.


1989 ◽  
Vol 60 (7) ◽  
pp. 1957-1960 ◽  
Author(s):  
T. Katsura ◽  
Y. Kamiya ◽  
T. Mitsuhashi ◽  
N. Nakamura ◽  
K. Haga ◽  
...  

1999 ◽  
Author(s):  
Sultan B. Dabagov ◽  
Igor I. Vlasov ◽  
Violetta A. Murashova ◽  
Mikhail V. Negodaev ◽  
Victor G. Ralchenko ◽  
...  

Nanoscale ◽  
2015 ◽  
Vol 7 (16) ◽  
pp. 7246-7251 ◽  
Author(s):  
N. Fukata ◽  
W. Jevasuwan ◽  
Y. Ikemoto ◽  
T. Moriwaki

The first report of B local vibrational peaks and electronic transitions of a bound hole from the ground state of a B acceptor atom to excited states by means of micro-FT-IR measurements using an IR-SR beam.


1998 ◽  
Vol 5 (3) ◽  
pp. 621-623 ◽  
Author(s):  
J.-R. Chen ◽  
T. S. Ueng ◽  
G. Y. Hsiung ◽  
T. F. Lin ◽  
C. T. Lee ◽  
...  

A prototype photon-beam-position monitor has been designed, fabricated and tested at the Taiwan Light Source of the Synchrotron Radiation Research Center. Aluminium was chosen as the material of the blade electrodes due to its low atomic number and high thermal conductivity. The resolution of this photon-beam-position monitor was <±1 µm. The sensitivity of the blade electrode has been measured in situ. Results of measurements for bending-magnet light and undulator light with different gaps are described.


1998 ◽  
Vol 5 (3) ◽  
pp. 759-761 ◽  
Author(s):  
Tatsuya Zama ◽  
Terubumi Saito ◽  
Hideo Onuki

A beamline which serves for calibrating transfer standard light sources (deuterium lamps, excimer lamps, Xe lamps etc.) in the UV and VUV regions is being constructed. The synchrotron radiation from the electron storage ring TERAS (750 MeV) is used as a primary standard of spectral radiant intensity. In order to use synchrotron radiation as a primary standard, the electron beam and synchrotron radiation beam parameters need to be evaluated. Uncertainties of synchrotron radiation flux evaluated by measurements of the magnetic flux density, the position of the electron orbital plane, the electron beam size and the distance from the synchrotron radiation tangent point to the detector system are expected to be about 0.003, 0.01, 0.05 and 0.1%, respectively.


Sign in / Sign up

Export Citation Format

Share Document