Signal-to-peak-interference ratio maximization with automatic interference weighting for threshold-based spike sorting of high-density neural probe data

Author(s):  
Jasper Wouters ◽  
Fabian Kloosterman ◽  
Alexander Bertrand
2018 ◽  
Vol 120 (6) ◽  
pp. 3155-3171 ◽  
Author(s):  
Roland Diggelmann ◽  
Michele Fiscella ◽  
Andreas Hierlemann ◽  
Felix Franke

High-density microelectrode arrays can be used to record extracellular action potentials from hundreds to thousands of neurons simultaneously. Efficient spike sorters must be developed to cope with such large data volumes. Most existing spike sorting methods for single electrodes or small multielectrodes, however, suffer from the “curse of dimensionality” and cannot be directly applied to recordings with hundreds of electrodes. This holds particularly true for the standard reference spike sorting algorithm, principal component analysis-based feature extraction, followed by k-means or expectation maximization clustering, against which most spike sorters are evaluated. We present a spike sorting algorithm that circumvents the dimensionality problem by sorting local groups of electrodes independently with classical spike sorting approaches. It is scalable to any number of recording electrodes and well suited for parallel computing. The combination of data prewhitening before the principal component analysis-based extraction and a parameter-free clustering algorithm obviated the need for parameter adjustments. We evaluated its performance using surrogate data in which we systematically varied spike amplitudes and spike rates and that were generated by inserting template spikes into the voltage traces of real recordings. In a direct comparison, our algorithm could compete with existing state-of-the-art spike sorters in terms of sensitivity and precision, while parameter adjustment or manual cluster curation was not required. NEW & NOTEWORTHY We present an automatic spike sorting algorithm that combines three strategies to scale classical spike sorting techniques for high-density microelectrode arrays: 1) splitting the recording electrodes into small groups and sorting them independently; 2) clustering a subset of spikes and classifying the rest to limit computation time; and 3) prewhitening the spike waveforms to enable the use of parameter-free clustering. Finally, we combined these strategies into an automatic spike sorter that is competitive with state-of-the-art spike sorters.


IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 218145-218160
Author(s):  
Gianluca Leone ◽  
Luigi Raffo ◽  
Paolo Meloni

2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Robert Scharf ◽  
Tomomi Tsunematsu ◽  
Niall McAlinden ◽  
Martin D. Dawson ◽  
Shuzo Sakata ◽  
...  

2012 ◽  
Vol 108 (1) ◽  
pp. 334-348 ◽  
Author(s):  
David Jäckel ◽  
Urs Frey ◽  
Michele Fiscella ◽  
Felix Franke ◽  
Andreas Hierlemann

Emerging complementary metal oxide semiconductor (CMOS)-based, high-density microelectrode array (HD-MEA) devices provide high spatial resolution at subcellular level and a large number of readout channels. These devices allow for simultaneous recording of extracellular activity of a large number of neurons with every neuron being detected by multiple electrodes. To analyze the recorded signals, spiking events have to be assigned to individual neurons, a process referred to as “spike sorting.” For a set of observed signals, which constitute a linear mixture of a set of source signals, independent component (IC) analysis (ICA) can be used to demix blindly the data and extract the individual source signals. This technique offers great potential to alleviate the problem of spike sorting in HD-MEA recordings, as it represents an unsupervised method to separate the neuronal sources. The separated sources or ICs then constitute estimates of single-neuron signals, and threshold detection on the ICs yields the sorted spike times. However, it is unknown to what extent extracellular neuronal recordings meet the requirements of ICA. In this paper, we evaluate the applicability of ICA to spike sorting of HD-MEA recordings. The analysis of extracellular neuronal signals, recorded at high spatiotemporal resolution, reveals that the recorded data cannot be modeled as a purely linear mixture. As a consequence, ICA fails to separate completely the neuronal signals and cannot be used as a stand-alone method for spike sorting in HD-MEA recordings. We assessed the demixing performance of ICA using simulated data sets and found that the performance strongly depends on neuronal density and spike amplitude. Furthermore, we show how postprocessing techniques can be used to overcome the most severe limitations of ICA. In combination with these postprocessing techniques, ICA represents a viable method to facilitate rapid spike sorting of multidimensional neuronal recordings.


2016 ◽  
Vol 10 ◽  
Author(s):  
Mu�ller Jan ◽  
Franke Felix ◽  
Fiscella Michele ◽  
Frey Urs ◽  
Bakkum Douglas ◽  
...  

Cell Reports ◽  
2017 ◽  
Vol 18 (10) ◽  
pp. 2521-2532 ◽  
Author(s):  
Gerrit Hilgen ◽  
Martino Sorbaro ◽  
Sahar Pirmoradian ◽  
Jens-Oliver Muthmann ◽  
Ibolya Edit Kepiro ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document