Optimal 2D Data Partitioning for DMA Transfers on MPSoCs

Author(s):  
Selma Saidi ◽  
Pranav Tendulkar ◽  
Thierry Lepley ◽  
Oded Maler
Keyword(s):  
2003 ◽  
Vol 42 (05) ◽  
pp. 215-219
Author(s):  
G. Platsch ◽  
A. Schwarz ◽  
K. Schmiedehausen ◽  
B. Tomandl ◽  
W. Huk ◽  
...  

Summary: Aim: Although the fusion of images from different modalities may improve diagnostic accuracy, it is rarely used in clinical routine work due to logistic problems. Therefore we evaluated performance and time needed for fusing MRI and SPECT images using a semiautomated dedicated software. Patients, material and Method: In 32 patients regional cerebral blood flow was measured using 99mTc ethylcystein dimer (ECD) and the three-headed SPECT camera MultiSPECT 3. MRI scans of the brain were performed using either a 0,2 T Open or a 1,5 T Sonata. Twelve of the MRI data sets were acquired using a 3D-T1w MPRAGE sequence, 20 with a 2D acquisition technique and different echo sequences. Image fusion was performed on a Syngo workstation using an entropy minimizing algorithm by an experienced user of the software. The fusion results were classified. We measured the time needed for the automated fusion procedure and in case of need that for manual realignment after automated, but insufficient fusion. Results: The mean time of the automated fusion procedure was 123 s. It was for the 2D significantly shorter than for the 3D MRI datasets. For four of the 2D data sets and two of the 3D data sets an optimal fit was reached using the automated approach. The remaining 26 data sets required manual correction. The sum of the time required for automated fusion and that needed for manual correction averaged 320 s (50-886 s). Conclusion: The fusion of 3D MRI data sets lasted significantly longer than that of the 2D MRI data. The automated fusion tool delivered in 20% an optimal fit, in 80% manual correction was necessary. Nevertheless, each of the 32 SPECT data sets could be merged in less than 15 min with the corresponding MRI data, which seems acceptable for clinical routine use.


1996 ◽  
Vol 51 (5-6) ◽  
pp. 337-347 ◽  
Author(s):  
Mariusz Maćkowiak ◽  
Piotr Kątowski

Abstract Two-dimensional zero-field nutation NQR spectroscopy has been used to determine the full quadrupolar tensor of spin - 3/2 nuclei in serveral molecular crystals containing the 3 5 Cl and 7 5 As nuclei. The problems of reconstructing 2D-nutation NQR spectra using conventional methods and the advantages of using implementation of the maximum entropy method (MEM) are analyzed. It is shown that the replacement of conventional Fourier transform by an alternative data processing by MEM in 2D NQR spectroscopy leads to sensitivity improvement, reduction of instrumental artefacts and truncation errors, shortened data acquisition times and suppression of noise, while at the same time increasing the resolution. The effects of off-resonance irradiation in nutation experiments are demonstrated both experimentally and theoretically. It is shown that off-resonance nutation spectroscopy is a useful extension of the conventional on-resonance experiments, thus facilitating the determination of asymmetry parameters in multiple spectrum. The theoretical description of the off-resonance effects in 2D nutation NQR spectroscopy is given, and general exact formulas for the asymmetry parameter are obtained. In off-resonance conditions, the resolution of the nutation NQR spectrum decreases with the spectrometer offset. However, an enhanced resolution can be achieved by using the maximum entropy method in 2D-data reconstruction.


2017 ◽  
Vol 10 (2) ◽  
pp. 166-182 ◽  
Author(s):  
Shabia Shabir Khan ◽  
S.M.K. Quadri

Purpose As far as the treatment of most complex issues in the design is concerned, approaches based on classical artificial intelligence are inferior compared to the ones based on computational intelligence, particularly this involves dealing with vagueness, multi-objectivity and good amount of possible solutions. In practical applications, computational techniques have given best results and the research in this field is continuously growing. The purpose of this paper is to search for a general and effective intelligent tool for prediction of patient survival after surgery. The present study involves the construction of such intelligent computational models using different configurations, including data partitioning techniques that have been experimentally evaluated by applying them over realistic medical data set for the prediction of survival in pancreatic cancer patients. Design/methodology/approach On the basis of the experiments and research performed over the data belonging to various fields using different intelligent tools, the authors infer that combining or integrating the qualification aspects of fuzzy inference system and quantification aspects of artificial neural network can prove an efficient and better model for prediction. The authors have constructed three soft computing-based adaptive neuro-fuzzy inference system (ANFIS) models with different configurations and data partitioning techniques with an aim to search capable predictive tools that could deal with nonlinear and complex data. After evaluating the models over three shuffles of data (training set, test set and full set), the performances were compared in order to find the best design for prediction of patient survival after surgery. The construction and implementation of models have been performed using MATLAB simulator. Findings On applying the hybrid intelligent neuro-fuzzy models with different configurations, the authors were able to find its advantage in predicting the survival of patients with pancreatic cancer. Experimental results and comparison between the constructed models conclude that ANFIS with Fuzzy C-means (FCM) partitioning model provides better accuracy in predicting the class with lowest mean square error (MSE) value. Apart from MSE value, other evaluation measure values for FCM partitioning prove to be better than the rest of the models. Therefore, the results demonstrate that the model can be applied to other biomedicine and engineering fields dealing with different complex issues related to imprecision and uncertainty. Originality/value The originality of paper includes framework showing two-way flow for fuzzy system construction which is further used by the authors in designing the three simulation models with different configurations, including the partitioning methods for prediction of patient survival after surgery. Several experiments were carried out using different shuffles of data to validate the parameters of the model. The performances of the models were compared using various evaluation measures such as MSE.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Muhammad Abbas ◽  
Ahmad Abd Majid ◽  
Jamaludin Md. Ali

We present the smooth and visually pleasant display of 2D data when it is convex, which is contribution towards the improvements over existing methods. This improvement can be used to get the more accurate results. An attempt has been made in order to develop the local convexity-preserving interpolant for convex data usingC2rational cubic spline. It involves three families of shape parameters in its representation. Data dependent sufficient constraints are imposed on single shape parameter to conserve the inherited shape feature of data. Remaining two of these shape parameters are used for the modification of convex curve to get a visually pleasing curve according to industrial demand. The scheme is tested through several numerical examples, showing that the scheme is local, computationally economical, and visually pleasing.


Cladistics ◽  
2017 ◽  
Vol 34 (1) ◽  
pp. 57-77 ◽  
Author(s):  
Limin Lu ◽  
Cymon J. Cox ◽  
Sarah Mathews ◽  
Wei Wang ◽  
Jun Wen ◽  
...  

2014 ◽  
Vol 54 (4) ◽  
pp. 295-300 ◽  
Author(s):  
Vladimir Socha ◽  
Patrik Kutilek ◽  
Ondrej Cakrt ◽  
Rudolf Cerny

Assessments of body-segment angular movements are very important in the rehabilitation process. Head angular movements are measured and analyzed for use in studies of stability and posture. However, there is no methodology for assessing angular movements of the head, and it has not been verified whether data measured by fundamentally different MoCap systems will lead to the same results. In this study, we used a camera system and a 3DOF orientation tracker placed on the subject’s head, and measured inclination (roll) and flexion (pitch) during quiet stance. The total length and the mean velocity of the traces of the pitch versus roll plots were used to measure and analyze head orientation. Using these methods, we are able to model the distribution of the measured 2D data, and to evaluate stability and posture. The results show that the total lengths and the mean velocities related to the 3DOF orientation tracker do not differ significantly from the total lengths and the mean velocities of traces related to the IR medical camera. We also found that the systems are not interchangeable, and that the same type of system must be used each time. The designed methods can be used for studies not only of head movements but also of movements of other segments of the human body, and can be used to compare other types of MoCap systems, depending on the requirements for a specific rehabilitation examination.


Sign in / Sign up

Export Citation Format

Share Document