scholarly journals V-band high efficiency corporate-fed 8×8 slot array antenna with ETSI class II radiation pattern based on gap technology

Author(s):  
Abbas Vosoogh ◽  
Per-Simon Kildal
Frequenz ◽  
2020 ◽  
Vol 74 (11-12) ◽  
pp. 383-392
Author(s):  
Rajveer S. Yaduvanshi ◽  
Richa Gupta ◽  
Saurabh Katiyar

AbstractSmartdielectric resonator antenna (DRA) having beam control mechanism is anew area to be explored by antenna researchers. Proposed new geometry DRA has low loss, design flexibility, high efficiency, compact size and desired radiated beam control. Developing beam control in new geometry DRAs is investigated for the first time in this letter. Unique technique for beam control and beam width control is proposed using pit top and mount top DRA. Gain is controlled from 5.0 to 9.98 dBi and beam is controlled from ±30° to ±70° in broadside radiation pattern. U shape pit DRA has maximum directive gain of 9.98 dBi and efficiency 98% at 5.8 GHz frequency. Measured and simulated results of radiation pattern and reflection coefficient are found to be in close proximity. Hardware of U shape pit top DRA, mount top DRA, left side arc top DRA, right side arc shape top DRA is developed and investigated. Mobile and cellular communication network need wide coverage, hence large beam width is required. Narrowing of beam width at higher order mode is also achieved.


1991 ◽  
Vol 4 (2) ◽  
pp. 207-241 ◽  
Author(s):  
R H Kruse ◽  
W H Puckett ◽  
J H Richardson

The biological safety cabinet is the one piece of laboratory and pharmacy equipment that provides protection for personnel, the product, and the environment. Through the history of laboratory-acquired infections from the earliest published case to the emergence of hepatitis B and AIDS, the need for health care worker protection is described. A brief description with design, construction, function, and production capabilities is provided for class I and class III safety cabinets. The development of the high-efficiency particulate air filter provided the impetus for clean room technology, from which evolved the class II laminar flow biological safety cabinet. The clean room concept was advanced when the horizontal airflow clean bench was manufactured; it became popular in pharmacies for preparing intravenous solutions because the product was protected. However, as with infectious microorganisms and laboratory workers, individual sensitization to antibiotics and the advent of hazardous antineoplastic agents changed the thinking of pharmacists and nurses, and they began to use the class II safety cabinet to prevent adverse personnel reactions to the drugs. How the class II safety cabinet became the mainstay in laboratories and pharmacies is described, and insight is provided into the formulation of National Sanitation Foundation standard number 49 and its revisions. The working operations of a class II cabinet are described, as are the variations of the four types with regard to design, function, air velocity profiles, and the use of toxins. The main certification procedures are explained, with examples of improper or incorrect certifications. The required levels of containment for microorganisms are given. Instructions for decontaminating the class II biological safety cabinet of infectious agents are provided; unfortunately, there is no method for decontaminating the cabinet of antineoplastic agents.


2018 ◽  
Vol 2018 ◽  
pp. 1-9
Author(s):  
Hongyu Shi ◽  
Jianxing Li ◽  
Shitao Zhu ◽  
Anxue Zhang ◽  
Zhuo Xu

In this paper, we proposed a radiation pattern reconfigurable waveguide slot array antenna using liquid crystal (LC). Together with the waveguide slot, the designed complementary electric-field-coupled resonator functions like a switch controlled by the dielectric constant of the LC, which can control the antenna element to radiate or not. Thus, the array factor and radiation pattern can be manipulated. The proposed antenna was simulated, fabricated, and measured. Its radiation direction can be reconfigured to 46° or 0° at about 15 GHz.


Sign in / Sign up

Export Citation Format

Share Document