Development of advanced built-in surge arresters for distribution system with new zinc-oxide elements

2001 ◽  
Vol 16 (4) ◽  
pp. 576-581 ◽  
Author(s):  
M. Hama ◽  
H. Ishizaka ◽  
J. Shimizu ◽  
S. Nishiki ◽  
I. Kaku
2014 ◽  
Vol 931-932 ◽  
pp. 857-861
Author(s):  
Wichet Thipprasert

Zinc Oxide (ZnO) surge arresters (SAs) experience thermal runaway when the temperature exceeds the acceptable limit. This phenomenon is associated with the increase in resistive leakage current due to degradation. This paper presents the electrical performance of ZnO SAs in 22 kV distribution system using thermal image camera under the power frequency AC operating voltages. When ZnO surge arresters are installation takes a long time in distribution system over than 5 years. For the experimental study, as ZnO installation takes a long time over than 6 years the leakage current is 63.9 mA, temperature difference were measured over a period of time over than 14 degree Celsius. This data will be useful as a guideline for solving problems and reducing power loss from leakage current. Moreover, it will be useful in predicting lifetime of ZnO SAs.


1981 ◽  
Vol PER-1 (11) ◽  
pp. 41-42 ◽  
Author(s):  
M. Oyama ◽  
I. Ohshima ◽  
M. Honda ◽  
M. Yamashita ◽  
S. Kojima

2001 ◽  
Vol 21 (8) ◽  
pp. 61-62
Author(s):  
M. Hama ◽  
H. Ishizaka ◽  
J. Shimizu ◽  
S. Nishiki ◽  
I. Kaku

1999 ◽  
Vol 14 (2) ◽  
pp. 393-398 ◽  
Author(s):  
P. Pinceti ◽  
M. Giannettoni

2000 ◽  
Vol 15 (2) ◽  
pp. 569-574 ◽  
Author(s):  
S. Shirakawa ◽  
S. Yamada ◽  
S. Tanaka ◽  
I. Ejiri ◽  
S. Watahiki ◽  
...  

2014 ◽  
Vol 960-961 ◽  
pp. 1073-1076
Author(s):  
Li Zhang ◽  
Kun Yang ◽  
Li Mei He

The index system for electrical characteristics of metal-oxide surge arresters is proposed and established, which is based on rated voltage (Ur), continuous operating voltage (Uc), nominal discharge current (In), overvoltage protection and insulation coordination including lightning overvoltage protection level, operating overvoltage protection level and coordination coefficient (Ks). The study considers both selection and application of overvoltage protection devices for the electrical equipments in 3-35kV medium voltage power system, and comparatively calculates and analyzes the main parameters between two types metal-oxide surge arresters (without gaps and containing series gapped structures), and illustrates their technical features and puts forward suggestions on how to improve the effective utilization. The results of 10kV power distribution system are simulated to show that the conclusions are feasible and available in the practical engineering application.


Sign in / Sign up

Export Citation Format

Share Document