Heterodyne detection with an injection laser. II. Signal-to-noise ratio

1990 ◽  
Vol 26 (4) ◽  
pp. 669-674 ◽  
Author(s):  
D. Marcuse
2018 ◽  
Vol 57 (34) ◽  
pp. 9898
Author(s):  
Gang Xia ◽  
Wei Fan ◽  
Xiaochao Wang ◽  
Jiangfeng Wang ◽  
Dajie Huang ◽  
...  

1983 ◽  
Vol 61 (2) ◽  
pp. 318-331 ◽  
Author(s):  
Denis Vincent ◽  
Gabriel Otis

We performed a theoretical and experimental study of a 10.6 μm heterodyne detection system with nonlinear postdetection. A single laser serves as both transmitter and local oscillator; the intermediate frequency is given by the Doppler effect due to a rotating target. An electrooptic crystal modulates the amplitude of the laser beam at a frequency of 15 kHz; a synchronous voltmeter measures the return signal after the nonlinear element. Values of the signal-to-noise ratio with respect to incident optical power agree with the results of the theoretical model. In particular, experimentally measured target-induced frequency spreading effects on the signal-to-noise ratio correspond to the predictions of the model. We also describe an experimental system.


1995 ◽  
Author(s):  
Nicusor Iftimia ◽  
Marek Strzelec ◽  
Ioan Spanulescu ◽  
Simion Ersen ◽  
Vasile D. Babin ◽  
...  

Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Sign in / Sign up

Export Citation Format

Share Document