Fire performance, including the cooling phase, of structural glued laminated timber beams

2016 ◽  
Vol 7 (4) ◽  
pp. 349-364 ◽  
Author(s):  
H. Kinjo ◽  
T. Hirashima ◽  
S. Yusa ◽  
T. Horio ◽  
T. Matsumoto

Purpose Based on heating tests and load-bearing fire tests, this paper aims to discuss the charring rate, the temperature distribution in the section and the load-bearing capacity of structural glued laminated timber beams not only during the heating phase during a 1-h standard fire in accordance with ISO 834-1 but also during the cooling phase. Design/methodology/approach Heating tests were carried out to confirm the charring rate and the temperature distribution in the cross-section of the beams. Loading tests under fire conditions were carried out to obtain the load-deformation behavior (i.e. the stiffness, maximum load and ductility) of the beam. Findings The temperature at the centroid reached approximately 30°C after 1 h and then increased gradually until reaching 110-200°C after 4 h, during the cooling phase. The maximum load of the specimen exposed to a 1-h standard fire was reduced to approximately 30 per cent of that of the specimen at ambient temperature. The maximum load of the specimen exposed to a 1-h standard fire and 3 h of natural cooling in the furnace was reduced to approximately 14 per cent. In case of taking into consideration of the strength reduction at elevated temperature, the reduction ratio of the calculated bending resistance agreed with that of the test results during not only heating phase but also cooling phase. Originality/value The results of this study state that it is possible to study on strength reduction in cooling phase for end of heating, timber structural which has not been clarified. It is believed that it is possible to appropriately evaluate the fire performance, including the cooling phase of the timber structural.

2018 ◽  
Vol 9 (4) ◽  
pp. 287-299
Author(s):  
Hitoshi Kinjo ◽  
Yusuke Katakura ◽  
Takeo Hirashima ◽  
Shuitsu Yusa ◽  
Kiyoshi Saito

Purpose This paper aims to discuss the fire performance of glulam timber beams based on their deflection behavior and load-bearing period, which were obtained from load-bearing fire tests under constant load conditions. Design/methodology/approach In this report, the fire performance, primarily deflection behavior and load-bearing period of glued laminated (glulam) timber beams will be discussed from the standpoint of load-bearing fire tests conducted during the cooling phase under constant load conditions. Then, based on the charring depth and the per section temperature transformation obtained from loading test results, the load-bearing capacity of the glulam timber beams will be discussed using the effective section method and the strength reduction factor, which will be calculated in accordance with the European standards for the design of timber structures (Eurocode 5). Findings In the cooling phase, the charring rate is decreases. However, as the temperature in the cross section rises, the deflection is increases. The failure mode was bending failure because of tensile failure of the lamina at the bottom of the beam. Moreover, a gap caused by shear failure in a growth ring in the beam cross-section in the vicinity of the centroid axis was observed. Shear failure was observed up until 1 to 3 h before end of heating. The calculated shear strength far exceeded the test results. Shear strength for elevated temperature of glued laminated timber is likely to decrease than the shear strength in Eurocode 5. Originality/value Unlike other elements, a characteristic problem of timber elements is that their load-bearing capacity decreases as they are consumed in a fire, and their bearing capacities may continue to degrade even after the fuel in the room has been exhausted. Therefore, the structural fire performance of timber elements should be clarified during not only the heating phase but also the subsequent cooling phase. However, there are few reports on the load-bearing capacity of timber elements that take the cooling phase after a fire into consideration.


2022 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Irindu Upasiri ◽  
Chaminda Konthesingha ◽  
Anura Nanayakkara ◽  
Keerthan Poologanathan ◽  
Gatheeshgar Perampalam ◽  
...  

PurposeLight-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel lipped channel sections negative fire performance, cavity insulation materials are utilized in the LSF configuration to enhance its fire performance. The applicability of lightweight concrete filling as cavity insulation in LSF and its effect on the fire performance of LSF are investigated under realistic design fire exposure, and results are compared with standard fire exposure.Design/methodology/approachA Finite Element model (FEM) was developed to simulate the fire performance of Light Gauge Steel Frame (LSF) walls exposed to realistic design fires. The model was developed utilising Abaqus subroutine to incorporate temperature-dependent properties of the material based on the heating and cooling phases of the realistic design fire temperature. The developed model was validated with the available experimental results and incorporated into a parametric study to evaluate the fire performance of conventional LSF walls compared to LSF walls with lightweight concrete filling under standard and realistic fire exposures.FindingsNovel FEM was developed incorporating temperature and phase (heating and cooling) dependent material properties in simulating the fire performance of structures exposed to realistic design fires. The validated FEM was utilised in the parametric study, and results exhibited that the LSF walls with lightweight concrete have shown better fire performance under insulation and load-bearing criteria in Eurocode parametric fire exposure. Foamed Concrete (FC) of 1,000 kg/m3 density showed best fire performance among lightweight concrete filling, followed by FC of 650 kg/m3 and Autoclaved Aerated Concrete (AAC) 600 kg/m3.Research limitations/implicationsThe developed FEM is capable of investigating the insulation and load-bearing fire ratings of LSF walls. However, with the availability of the elevated temperature mechanical properties of the LSF wall, materials developed model could be further extended to simulate the complete fire behaviour.Practical implicationsLSF structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel-lipped channel sections negative fire performance, cavity insulation materials are utilised in the LSF configuration to enhance its fire performance. The lightweight concrete filling in LSF is a novel idea that could be practically implemented in the construction, which would enhance both fire performance and the mechanical performance of LSF walls.Originality/valueLimited studies have investigated the fire performance of structural elements exposed to realistic design fires. Numerical models developed in those studies have considered a similar approach as models developed to simulate standard fire exposure. However, due to the heating phase and the cooling phase of the realistic design fires, the numerical model should incorporate both temperature and phase (heating and cooling phase) dependent properties, which was incorporated in this study and validated with the experimental results. Further lightweight concrete filling in LSF is a novel technique in which fire performance was investigated in this study.


2017 ◽  
Vol 8 (4) ◽  
pp. 354-376 ◽  
Author(s):  
Mohamed Rusthi ◽  
Poologanathan Keerthan ◽  
Mahen Mahendran ◽  
Anthony Ariyanayagam

Purpose This research was aimed at investigating the fire performance of LSF wall systems by using 3-D heat transfer FE models of existing LSF wall system configurations. Design/methodology/approach This research was focused on investigating the fire performance of LSF wall systems by using 3-D heat transfer finite element models of existing LSF wall system configurations. The analysis results were validated by using the available fire test results of five different LSF wall configurations. Findings The validated finite element models were used to conduct a parametric study on a range of non-load bearing and load bearing LSF wall configurations to predict their fire resistance levels (FRLs) for varying load ratios. Originality/value Fire performance of LSF wall systems with different configurations can be understood by performing full-scale fire tests. However, these full-scale fire tests are time consuming, labour intensive and expensive. On the other hand, finite element analysis (FEA) provides a simple method of investigating the fire performance of LSF wall systems to understand their thermal-mechanical behaviour. Recent numerical research studies have focused on investigating the fire performances of LSF wall systems by using finite element (FE) models. Most of these FE models were developed based on 2-D FE platform capable of performing either heat transfer or structural analysis separately. Therefore, this paper presents the details of a 3-D FEA methodology to develop the capabilities to perform fully-coupled thermal-mechanical analyses of LSF walls exposed to fire in future.


2020 ◽  
Vol 11 (4) ◽  
pp. 529-543
Author(s):  
Anjaly Nair ◽  
Osama (Sam) Salem

Purpose At elevated temperatures, concrete undergoes changes in its mechanical and thermal properties, which mainly cause degradation of strength and eventually may lead to the failure of the structure. Retrofitting is a desirable option to rehabilitate fire damaged concrete structures. However, to ensure safe reuse of fire-exposed buildings and to adopt proper retrofitting methods, it is essential to evaluate the residual load-bearing capacity of such fire-damaged reinforced concrete structures. The focus of the experimental study presented in this paper aims to investigate the fire performance of concrete columns exposed to a standard fire, and then evaluate its residual compressive strengths after fire exposure of different durations. Design/methodology/approach To effectively study the fire performance of such columns, eight identical 200 × 200 × 1,500-mm high reinforced concrete columns test specimens were subjected to two different fire exposure (1- and 2-h) while being loaded with two different load ratios (20% and 40% of the column ultimate design axial compressive load). In a subsequent stage and after complete cooling down, residual compressive strength capacity tests were performed on each fire exposed column. Findings Experimental results revealed that the columns never regain its original capacity after being subjected to a standard fire and that the residual compressive strength capacity dropped to almost 50% and 30% of its ambient temperature capacity for the columns exposed to 1- and 2-h fire durations, respectively. It was also noticed that, for the tested columns, the applied load ratio has much less effect on the column’s residual compressive strength compared to that of the fire duration. Originality/value According to the unique outcomes of this experimental study and, as the fire-damaged concrete columns possessed considerable residual compressive strength, in particular those exposed to shorter fire duration, it is anticipated that with proper retrofitting techniques such as fiber-reinforced polymers (FRP) wrapping, the fire-damaged columns can be rehabilitated to regain at least portion of its lost load-bearing capacities. Accordingly, the residual compressive resistance data obtained from this study can be effectively used but not directly to adopt optimal retrofitting strategies for such fire-damaged concrete columns, as well as to be used in validating numerical models that can be usefully used to account for the thermally-induced degradation of the mechanical properties of concrete material and ultimately predict the residual compressive strengths and deformations of concrete columns subjected to different load intensity ratios for various fire durations.


2022 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Oluwamuyiwa Okunrounmu ◽  
Osama (Sam) Salem ◽  
George Hadjisophocleous

PurposeThe fire resistance of timber structures is heavily dependent on the fire behaviour of the connections between its structural elements. The experimental study presented in this paper aimed to investigate the fire performance of glued-laminated timber beam connections reinforced perpendicular-to-wood grain with self-tapping screws (STS).Design/methodology/approachTwo full-size fire experiments were conducted on glulam beam-end connections loaded in flexure bending. Two connection configurations, each utilizing four steel bolts arranged in two different patterns, were reinforced perpendicular to wood grain using STS. The bolt heads and nuts and the steel plate top and bottom edges were fire protected using wood plugs and strips, respectively. Each connection configuration was loaded to 100% of the ultimate design load of the weakest unreinforced configuration. The test assemblies were exposed to elevated temperatures that followed the CAN/ULC-S101 standard fire time–temperature curve.FindingsThe experimental results show that the influence of the STS was significant as it prevented the occurrence of wood splitting and row shear-out and as a result, increased the fire resistance time of the connections. The time to failure of both connection configurations exceeded the minimum fire resistance rating specified as 45 min for combustible construction in applicable building codes.Originality/valueThe experimental data show the effectiveness of a simple fire protection system (i.e. wood plugs and strips) along with the utilization of STS on the rotational behaviour, charring rate, fire resistance time and failure mode of the proposed hybrid mass timber beam-end connection configurations.


2018 ◽  
Vol 9 (2) ◽  
pp. 126-137
Author(s):  
Hirokazu Ohashi ◽  
Shinya Igarashi ◽  
Tsutomu Nagaoka

Purpose As forestry contributes to the reduction of greenhouse gases by CO2 fixation, in recent years, use of wood in buildings has attracted all over the world more attention. However, construction of large wood structures is almost inexistent within urban areas in Japan. This is due to the Japanese law on fire protection of wood buildings in cities, which is considered very strict with severe requirements. This paper aims to present a research work relative to the development of one-hour fire-resistant wood structural elements for buildings in cities. The developed elements are composed of three layers made of laminated timber. Design/methodology/approach These wood structural elements, made of glued laminated timber with self-charring-stop, have sufficient fire resistance during and after a fire and comply with the strict Japanese standard for wood structural elements, which stipulates that such elements have to withstand the whole dead-load of concerned buildings after fire. To comply with such requirements, new elements of glued laminated timber with self-charring-stop layer were developed, and their performance was confirmed. Several fire-resistant tests conducted on columns, beams, column-beam joints, connections between beams and walls and beams with holes were carried out. Findings All tests proved that the elements have sufficient fire resistance. No damage was found out at the load-bearing part of the elements after testing. As the developed elements have two layers protecting the load-bearing part, the temperature in the load-bearing part could be retained below 260°C (carbonization temperature) and provide the elements with a sufficient fire resistance for 1 h. Practical implications These wood structural elements have already been applied in six projects, where large-size wooden buildings were constructed in urban areas in Japan. Originality/value The proposed structural elements use a novel technique. Every wooden element is composed of three layers made of glued laminated timber. The elements have a typical performance of self-charring-stop after fire without need for water of firefighters. More technologies related to these elements, including column-beam joints and beams with holes and effect of crack, were also developed to design and construct safe wooden buildings.


2009 ◽  
Vol 44 (2) ◽  
pp. 231-236 ◽  
Author(s):  
Te-Hsin Yang ◽  
Song-Yung Wang ◽  
Ming-Jer Tsai ◽  
Ching-Yuan Lin

2018 ◽  
Vol 9 (3) ◽  
pp. 222-236 ◽  
Author(s):  
Joachim Schmid ◽  
Alessandro Santomaso ◽  
Daniel Brandon ◽  
Ulf Wickström ◽  
Andrea Frangi

Purpose The purpose of this study is to investigate the influencing factors on the charring behaviour of timber, the char layer and the charring depth in non-standard fires. Design/methodology/approach This paper summarizes outcomes of tests, investigating the influences on the charring behavior of timber by varying the oxygen content and the gas velocity in the compartment. Results show that charring is depending on the fire compartment temperature, but results show further that at higher oxygen flow, char contraction was observed affecting the protective function of the char layer. Findings In particular, in the cooling phase, char contraction should be considered which may have a significant impact on performance-based design using non-standard temperature fire curves where the complete fire history including the cooling phase has to be taken into account. Originality/value Up to now, some research on non-standard fire exposed timber member has been performed, mainly based on standard fire resistance tests where boundary conditions as gas flow and oxygen content especially in the decay phase are not measured or documented. The approach presented in this paper is the first documented fire tests with timber documenting the data required.