scholarly journals Li7 -induced reaction on Monat : A study of complete versus incomplete fusion

2017 ◽  
Vol 96 (1) ◽  
Author(s):  
Deepak Kumar ◽  
Moumita Maiti ◽  
Susanta Lahiri
Author(s):  
H. S. Kim ◽  
R. U. Lee

A heating element/electrical conduit assembly used in the Orbiter Maneuvering System failed a leak test during a routine refurbishment inspection. The conduit, approximately 100 mm in length and 12 mm in diameter, was fabricated from two tubes and braze-joined with a sleeve. The tube on the high temperature side (heating element side) and the sleeve were made of Inconel 600 and the other tube was stainless steel (SS) 316. For the filler metal, a Ni-Cr-B brazing alloy per AWS BNi-2, was used. A Helium leak test spotted the leak located at the joint between the sleeve and SS 316 tubing. This joint was dissected, mounted in a plastic mold, polished, and examined with an optical microscope. Debonding of the brazed surfaces was noticed, more pronounced toward the sleeve end which was exposed to uncontrolled atmospheric conditions intermittently. Initially, lack of wetting was suspected, presumably caused by inadequate surface preparation or incomplete fusion of the filler metal. However, this postulation was later discarded based upon the following observations: (1) The angle of wetting between the fillet and tube was small, an indication of adequate wetting, (2) the fillet did not exhibit a globular microstructure which would be an indication of insufficient melting of the filler metal, and (3) debonding was intermittent toward the midsection of the sleeve.


Author(s):  
D. Singh ◽  
◽  
S. Bharti Linda ◽  
Pankaj Kumar Giri ◽  
H. Kumar ◽  
...  

1995 ◽  
Vol 60 (1) ◽  
pp. 104-114 ◽  
Author(s):  
Boyd L. Earl ◽  
Richard L. Titus

Previous reports on the thermal or CO2-laser induced decomposition of trichloroethylene have identified only one condensible product, hexachlorobenzene (in addition to HCl and mono- and dichloroacetylene). We have found that trichloroethylene vapor exposed to cw irradiation on the P(24) line of the (001 - 100) band of the CO2 laser at incident power levels from 8 - 17 W produces numerous products, of which the 13 major ones have been identified using IR, GC/MS, GC/FTIR, and NMR methods. All of these products have 4, 6, or 8 carbons, are highly unsaturated, and are completely chlorinated or contain a single hydrogen. C4HCl5 and C6Cl6 isomers (three of each) account for S 55% to 85% of total products (based on peak areas in the total ion chromatograms in GC/MS runs), depending on reaction conditions. In addition to characterizing the products, we discuss the dependence of the product distribution on laser power, irradiation time, and cell geometry, and we outline a possible mechanism.


2020 ◽  
Vol 102 (6) ◽  
Author(s):  
M. R. Cortes ◽  
J. Rangel ◽  
J. L. Ferreira ◽  
J. Lubian ◽  
L. F. Canto

2021 ◽  
pp. 138572
Author(s):  
Jing Guo ◽  
Ye-Jun Li ◽  
Jun-Ping Ma ◽  
Xian Tang ◽  
Xue-Shen Liu

2010 ◽  
Vol 132 (13) ◽  
pp. 134903 ◽  
Author(s):  
Alessio Zaccone ◽  
Daniele Gentili ◽  
Massimo Morbidelli

Sign in / Sign up

Export Citation Format

Share Document