scholarly journals Range of motion and between-measurement variation of spinal kinematics in sound horses at trot on the straight line and on the lunge

2019 ◽  
Author(s):  
A. Hardeman ◽  
A. Byström ◽  
L. Roepstorff ◽  
J.H. Swagemakers ◽  
P.R. van Weeren ◽  
...  

AbstractClinical assessment of spinal motion in horses is part of many routine clinical exams but remains highly subjective. A prerequisite for the quantification is the assessment of the expected normal range of motion and variability of back kinematics. The aim of this study was to objectively quantify spinal kinematics and between-measurement, -surface and -day variation in owner-sound horses. In an observational study, twelve owner-sound horses were trotted 12 times on four different paths (hard/soft straight line, soft lunge left and right). Measurements were divided over three days, with five repetitions on day one and two, and two repetitions on day three (recheck) which occurred 28-55 days later. Optical motion capture was used to collect kinematic data. Elements of the outcome were: 1) Ranges of Motion (ROM) with confidence intervals per path and surface, 2) a variability model to calculate between-measurement variation and test the effect of time, surface and path, 3) intraclass correlation coefficients (ICC) to determine repeatability. ROM was lowest on the hard straight line. Cervical lateral bending was doubled on the left compared to the right lunge. Mean variation for the flexion-extension and lateral bending of the whole back were 0.8 and 1 degrees. Pelvic motion showed a variation of 1.0 (pitch), 0.7 (yaw) and 1.3 (roll) degrees. For these five parameters, a tendency for more variation on the hard surface and reduced variation with increased repetitions was observed. More variation was seen on the recheck (p<0.001). ICC values for the pelvis were between 0.76 and 0.93, for the whole back flexion-extension and lateral bending between 0.51 and 0.91. Between-horse variation was substantially higher than within-horse variation. Concluding, ROM and variation in spinal biomechanics are horse-specific and small, necessitating individual analysis and making subjective clinical assessment of spinal kinematics challenging.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
A. Byström ◽  
A. M. Hardeman ◽  
F. M. Serra Bragança ◽  
L. Roepstorff ◽  
J. H. Swagemakers ◽  
...  

AbstractWork on curved tracks, e.g. on circles, is commonplace within all forms of horse training. Horse movements in circles are naturally asymmetric, including the load distribution between inner and outer limbs. Within equestrian dressage the horse is expected to bend the back laterally to follow the circle, but this has never been studied scientifically. In the current study 12 horses were measured (optical motion capture, 100 Hz) trotting on left and right circles and on the straight without rider (soft surface). Data from markers placed along the spine indicated increased lateral bending to the inside (e.g. left bending on the left circle) of the thoracolumbar back (difference left circle vs. straight − 3.75°; right circle + 3.61°) and the neck (left − 5.23°; right + 4.80° vs. straight). Lateral bending ROM increased on the circle (+ 0.87° and + 0.62°). Individual variation in straight-circle differences was evident, but each horse was generally consistent over multiple trials. Differences in back movements between circle and straight were generally small and may or may not be visible, but accompanying changes in muscle activity and limb movements may add to the visual impression.


PLoS ONE ◽  
2020 ◽  
Vol 15 (2) ◽  
pp. e0222822
Author(s):  
A. M. Hardeman ◽  
A. Byström ◽  
L. Roepstorff ◽  
J. H. Swagemakers ◽  
P. R. van Weeren ◽  
...  

Author(s):  
Henriëtte A. W. Meijer ◽  
Maurits Graafland ◽  
Miryam C. Obdeijn ◽  
Marlies P. Schijven ◽  
J. Carel Goslings

Abstract Purpose To determine the validity of wrist range of motion (ROM) measurements by the wearable-controlled ReValidate! wrist-rehabilitation game, which simultaneously acts as a digital goniometer. Furthermore, to establish the reliability of the game by contrasting ROM measurements to those found by medical experts using a universal goniometer. Methods As the universal goniometer is considered the reference standard, inter-rater reliability between surgeons was first determined. Internal validity of the game ROM measurements was determined in a test–retest setting with healthy volunteers. The reliability of the game was tested in 34 patients with a restricted range of motion, in whom the ROM was measured by experts as well as digitally. Intraclass-correlation coefficients (ICCs) were determined and outcomes were analyzed using Bland–Altman plots. Results Inter-rater reliability between experts using a universal goniometer was poor, with ICCs of 0.002, 0.160 and 0.520. Internal validity testing of the game found ICCs of − 0.693, 0.376 and 0.863, thus ranging from poor to good. Reliability testing of the game compared to medical expert measurements, found that mean differences were small for the flexion–extension arc and the radial deviation-ulnar deviation arc. Conclusion The ReValidate! game is a reliable home-monitoring device digitally measuring ROM in the wrist. Interestingly, the test–retest reliability of the serious game was found to be considerably higher than the inter-rater reliability of the reference standard, being healthcare professionals using a universal goniometer. Trial registration number (internal hospital registration only) MEC-AMC W17_003 #17.015.


Author(s):  
Héctor E Jaramillo S

The annulus fibrosus has substantial variations in its geometrical properties (among individuals and between levels), and plays an important role in the biomechanics of the spine. Few works have studied the influence of the geometrical properties including annulus area, anterior / posterior disc height, and over the range of motion, but in general these properties have not been reported in the finite element models. This paper presents a probabilistic finite element analyses (Abaqus 6.14.2) intended to assess the effects of the average disc height ( hp) and the area ( A) of the annulus fibrosus on the biomechanics of the lumbar spine. The annulus model was loaded under flexion, extension, lateral bending, and axial rotation and analyzed for different combinations of hpand A in order to obtain their effects over the range of motion. A set of 50 combinations of hp(mean = 18.1 mm, SD = 3.5 mm) and A (mean = 49.8%, SD = 4.6%) were determined randomly according to a normal distribution. A Yeoh energy function was used for the matrix and an exponential function for the fibers. The range of motion was more sensitive to hpthan to A. With regard to the range of motion the segment was more sensitive in the following order: flexion, axial rotation, extension, and lateral bending. An increase of the hpproduces an increase of the range of motion, but this decreases when A increases. Comparing the range of motion with the experimental data, on average, 56.0% and 73.0% of the total of data were within the experimental range for the L4–L5 and L5–S1 segments, respectively. Further, an analytic equation was derived to obtain the range of motion as a function of the hpand A. This equation can be used to calibrate a finite element model of the spine segment, and also to understand the influence of each geometrical parameter on the range of motion.


PeerJ ◽  
2020 ◽  
Vol 8 ◽  
pp. e9687
Author(s):  
Vanina Costa ◽  
Óscar Ramírez ◽  
Abraham Otero ◽  
Daniel Muñoz-García ◽  
Sandra Uribarri ◽  
...  

Background Elbow and wrist chronic conditions are very common among musculoskeletal problems. These painful conditions affect muscle function, which ultimately leads to a decrease in the joint’s Range Of Motion (ROM). Due to their portability and ease of use, goniometers are still the most widespread tool for measuring ROM. Inertial sensors are emerging as a digital, low-cost and accurate alternative. However, whereas inertial sensors are commonly used in research studies, due to the lack of information about their validity and reliability, they are not widely used in the clinical practice. The goal of this study is to assess the validity and intra-inter-rater reliability of inertial sensors for measuring active ROM of the elbow and wrist. Materials and Methods Measures were taken simultaneously with inertial sensors (Werium™ system) and a universal goniometer. The process involved two physiotherapists (“rater A” and “rater B”) and an engineer responsible for the technical issues. Twenty-nine asymptomatic subjects were assessed individually in two sessions separated by 48 h. The procedure was repeated by rater A followed by rater B with random order. Three repetitions of each active movement (elbow flexion, pronation, and supination; and wrist flexion, extension, radial deviation and ulnar deviation) were executed starting from the neutral position until the ROM end-feel; that is, until ROM reached its maximum due to be stopped by the anatomy. The coefficient of determination (r2) and the Intraclass Correlation Coefficient (ICC) were calculated to assess the intra-rater and inter-rater reliability. The Standard Error of the Measurement and the Minimum Detectable Change and a Bland–Altman plots were also calculated. Results Similar ROM values when measured with both instruments were obtained for the elbow (maximum difference of 3° for all the movements) and wrist (maximum difference of 1° for all the movements). These values were within the normal range when compared to literature studies. The concurrent validity analysis for all the movements yielded ICC values ≥0.78 for the elbow and ≥0.95 for the wrist. Concerning reliability, the ICC values denoted a high reliability of inertial sensors for all the different movements. In the case of the elbow, intra-rater and inter-rater reliability ICC values range from 0.83 to 0.96 and from 0.94 to 0.97, respectively. Intra-rater analysis of the wrist yielded ICC values between 0.81 and 0.93, while the ICC values for the inter-rater analysis range from 0.93 to 0.99. Conclusions Inertial sensors are a valid and reliable tool for measuring elbow and wrist active ROM. Particularly noteworthy is their high inter-rater reliability, often questioned in measurement tools. The lowest reliability is observed in elbow prono-supination, probably due to skin artifacts. Based on these results and their advantages, inertial sensors can be considered a valid assessment tool for wrist and elbow ROM.


2019 ◽  
Vol 10 (8) ◽  
pp. 973-981
Author(s):  
Raymond J. Hah ◽  
Ram Alluri ◽  
Paul A. Anderson

Study Design: Biomechanics study. Objectives: To evaluate the biomechanical advantage of interfacet allograft spacers in an unstable single-level and 2-level anterior cervical discectomy and fusion (ACDF) pseudoarthrosis model. Methods: Nine single-level and 8 two-level ACDF constructs were tested. Range of motion in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) at 1.5 N m were collected in 4 testing configurations: (1) intact spine, (2) ACDF with interbody graft and plate/screw, (3) ACDF with interbody graft and plate/loosened screws (loose condition), and (4) ACDF with interbody graft and plate/loosened screws supplemented with interfacet allograft spacers (rescue condition). Results: All fixation configurations resulted in statistically significant decreases in range of motion in all bending planes compared with the intact spine ( P < .05). One Level. Performing ACDF with interbody graft and plate on the intact spine reduced FE, LB, and AR 60.0%, 64.9%, and 72.9%, respectively. Loosening the ACDF screws decreased these reductions to 40.9%, 44.6%, and 52.1%. The addition of interfacet allograft spacers to the loose condition increased these reductions to 74.0%, 84.1%, and 82.1%. Two Level. Performing ACDF with interbody graft and plate on the intact spine reduced FE, LB, and AR 72.0%, 71.1%, and 71.2%, respectively. Loosening the ACDF screws decreased these reductions to 55.4%, 55.3%, and 51.3%. The addition of interfacet allograft spacers to the loose condition significantly increased these reductions to 82.6%, 91.2%, and 89.3% ( P < .05). Conclusions: Supplementation of a loose ACDF construct (pseudarthrosis model) with interfacet allograft spacers significantly increases stability and has potential applications in treating cervical pseudarthrosis.


Animals ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 301
Author(s):  
Cajsa Ericson ◽  
Pernilla Stenfeldt ◽  
Aagje Hardeman ◽  
Inger Jacobson

Kinesiotape theoretically stimulates mechanoreceptive and proprioceptive sensory pathways that in turn may modulate the neuromuscular activity and locomotor function, so alteration of activation, locomotion and/or range of motion (ROM) can be achieved. The aim of this study was to determine whether kinesiotape applied to the abdominal muscles would affect the ROM in flexion-extension (sagittal plane) in the thoracolumbar back of horses at trot. The study design was a paired experimental study, with convenient sample. Each horse was randomly placed in the control or the intervention group and then the order reversed. Eight horses trotted at their own preferred speed in hand on a straight line, 2 × 30 m. Optical motion capture was used to collect kinematic data. Paired t-tests, normality tests and 1-Sample Wilcoxon test were used to assess the effects of the kinesiotape. No statistical significance (p < 0.05) for changes in flexion-extension of the thoracolumbar back in trot was shown in this group of horses. Some changes were shown indicating individual movement strategies in response to stimuli from the kinesiotape. More research in this popular and clinically used method is needed to fully understand the reacting mechanisms in horses.


2008 ◽  
Vol 63 (suppl_4) ◽  
pp. ONS303-ONS308 ◽  
Author(s):  
Şeref Doğan ◽  
Seungwon Baek ◽  
Volker K.H. Sonntag ◽  
Neil R. Crawford

Abstract Objective: To evaluate the differences in spinal stability and stabilizing potential of instrumentation after cervical corpectomy and spondylectomy. Methods: Seven human cadaveric specimens were tested: 1) intact; 2) after grafted C5 corpectomy and anterior C4–C6 plate; 3) after adding posterior C4–C6 screws/rods; 4) after extending posteriorly to C3–C7; 5) after grafted C5 spondylectomy, anterior C4–C6 plate, and posterior C4–C6 screws/rods; and 6) after extending posteriorly to C3–C7. Pure moments induced flexion, extension, lateral bending, and axial rotation; angular motion was recorded optically. Results: After corpectomy, anterior plating alone reduced the angular range of motion to a mean of 30% of normal, whereas added posterior short- or long-segment hardware reduced range of motion significantly more (P &lt; 0.003), to less than 5% of normal. Constructs with posterior rods spanning C3–C7 were stiffer than constructs with posterior rods spanning C4–C6 during flexion, extension, and lateral bending (P &lt; 0.05), but not during axial rotation (P &gt; 0.07). Combined anterior and C4–C6 posterior fixation exhibited greater stiffness after corpectomy than after spondylectomy during lateral bending (P = 0.019) and axial rotation (P = 0.001). Combined anterior and C3–C7 posterior fixation exhibited greater stiffness after corpectomy than after spondylectomy during extension (P = 0.030) and axial rotation (P = 0.0001). Conclusion: Circumferential fixation provides more stability than anterior instrumentation alone after cervical corpectomy. After corpectomy or spondylectomy, long circumferential instrumentation provides better stability than short circumferential fixation except during axial rotation. Circumferential fixation more effectively prevents axial rotation after corpectomy than after spondylectomy.


Sensors ◽  
2019 ◽  
Vol 19 (23) ◽  
pp. 5143 ◽  
Author(s):  
Lukas Adamowicz ◽  
Reed Gurchiek ◽  
Jonathan Ferri ◽  
Anna Ursiny ◽  
Niccolo Fiorentino ◽  
...  

Wearable sensor-based algorithms for estimating joint angles have seen great improvements in recent years. While the knee joint has garnered most of the attention in this area, algorithms for estimating hip joint angles are less available. Herein, we propose and validate a novel algorithm for this purpose with innovations in sensor-to-sensor orientation and sensor-to-segment alignment. The proposed approach is robust to sensor placement and does not require specific calibration motions. The accuracy of the proposed approach is established relative to optical motion capture and compared to existing methods for estimating relative orientation, hip joint angles, and range of motion (ROM) during a task designed to exercise the full hip range of motion (ROM) and fast walking using root mean square error (RMSE) and regression analysis. The RMSE of the proposed approach was less than that for existing methods when estimating sensor orientation ( 12 . 32 ∘ and 11 . 82 ∘ vs. 24 . 61 ∘ and 23 . 76 ∘ ) and flexion/extension joint angles ( 7 . 88 ∘ and 8 . 62 ∘ vs. 14 . 14 ∘ and 15 . 64 ∘ ). Also, ROM estimation error was less than 2 . 2 ∘ during the walking trial using the proposed method. These results suggest the proposed approach presents an improvement to existing methods and provides a promising technique for remote monitoring of hip joint angles.


2020 ◽  
Vol 43 (12) ◽  
pp. 803-810 ◽  
Author(s):  
Masud Rana ◽  
Sandipan Roy ◽  
Palash Biswas ◽  
Shishir Kumar Biswas ◽  
Jayanta Kumar Biswas

The aim of this study is to design a novel expanding flexible rod device, for pedicle screw fixation to provide dynamic stability, based on strength and flexibility. Three-dimensional finite-element models of lumbar spine (L1-S) with flexible rod device on L3-L4-L5 levels are developed. The implant material is taken to be Ti-6Al-4V. The models are simulated under different boundary conditions, and the results are compared with intact model. In natural model, total range of motion under 10 Nm moment were found 66.7°, 24.3° and 13.59°, respectively during flexion–extension, lateral bending and axial rotation. The von Mises stress at intact bone was 4 ± 2 MPa and at bone, adjacent to the screw in the implanted bone, was 6 ± 3 MPa. The von Mises stress of disc of intact bone varied from 0.36 to 2.13 MPa while that of the disc between the fixed vertebra of the fixation model reduced by approximately 10% for flexion and 25% for extension compared to intact model. The von Mises stresses of pedicle screw were 120, 135, 110 and 90 MPa during flexion, extension, lateral bending, and axial rotation, respectively. All the stress values were within the safe limit of the material. Using the flexible rod device, flexibility was significantly increased in flexion/extension but not in axial rotation and lateral bending. The results suggest that dynamic stabilization system with respect to fusion is more effective for homogenizing the range of motion of the spine.