Mechanical testing of bones: the positive synergy of finite–element models and in vitro experiments

Author(s):  
Luca Cristofolini ◽  
Enrico Schileo ◽  
Mateusz Juszczyk ◽  
Fulvia Taddei ◽  
Saulo Martelli ◽  
...  

Bone biomechanics have been extensively investigated in the past both with in vitro experiments and numerical models. In most cases either approach is chosen, without exploiting synergies. Both experiments and numerical models suffer from limitations relative to their accuracy and their respective fields of application. In vitro experiments can improve numerical models by: (i) preliminarily identifying the most relevant failure scenarios; (ii) improving the model identification with experimentally measured material properties; (iii) improving the model identification with accurately measured actual boundary conditions; and (iv) providing quantitative validation based on mechanical properties (strain, displacements) directly measured from physical specimens being tested in parallel with the modelling activity. Likewise, numerical models can improve in vitro experiments by: (i) identifying the most relevant loading configurations among a number of motor tasks that cannot be replicated in vitro ; (ii) identifying acceptable simplifications for the in vitro simulation; (iii) optimizing the use of transducers to minimize errors and provide measurements at the most relevant locations; and (iv) exploring a variety of different conditions (material properties, interface, etc.) that would require enormous experimental effort. By reporting an example of successful investigation of the femur, we show how a combination of numerical modelling and controlled experiments within the same research team can be designed to create a virtuous circle where models are used to improve experiments, experiments are used to improve models and their combination synergistically provides more detailed and more reliable results than can be achieved with either approach singularly.

1991 ◽  
Vol 113 (4) ◽  
pp. 353-360 ◽  
Author(s):  
J. C. Lotz ◽  
E. J. Cheal ◽  
W. C. Hayes

Over 90 percent of the more than 250,000 hip fractures that occur annually in the United States are the result of falls from standing height. Despite this, the stresses associated with femoral fracture from a fall have not been investigated previously. Our objectives were to use three-dimensional finite element models of the proximal femur (with geometries and material properties based directly on quantitative computed tomography) to compare predicted stress distributions for one-legged stance and for a fall to the lateral greater trochanter. We also wished to test the correspondence between model predictions and in vitro strain gage data and failure loads for cadaveric femora subjected to these loading conditions. An additional goal was to use the model predictions to compare the sensitivity of several imaging sites in the proximal femur which are used for the in vivo prediction of hip fracture risk. In this first of two parts, linear finite element models of two unpaired human cadaveric femora were generated. In Part II, the models were extended to include nonlinear material properties for the cortical and trabecular bone. While there was poor correspondence between strain gage data and model predictions, there was excellent agreement between the in vitro failure data and the linear model, especially using a von Mises effective strain failure criterion. Both the onset of structural yielding (within 22 and 4 percent) and the load at fracture (within 8 and 5 percent) were predicted accurately for the two femora tested. For the simulation of one-legged stance, the peak stresses occurred in the primary compressive trabeculae of the subcapital region. However, for a simulated fall, the peak stresses were in the intertrochanteric region. The Ward’s triangle (basicervical) site commonly used for the clinical assessment of osteoporosis was not heavily loaded in either situation. These findings suggest that the intertrochanteric region may be the most sensitive site for the assessment of fracture risk due to a fall and the subcapital region for fracture risk due to repetitive activities such as walking.


Author(s):  
Timothy J. Corbett ◽  
Barry J. Doyle ◽  
Anthony Callanan ◽  
Tim M. McGloughlin

A vast amount of experimental research has been undertaken in the past decade to investigate different aspects of preoperative and postoperative abdominal aortic aneurysms (AAAs). Much of this research has been based on the use of mock arteries in an in vitro flow loop to mimic the behaviour of the abdominal aorta in vivo [1]. These models should be reproducible, have consistent material properties, consistent thickness and be physiological in behaviour.


2010 ◽  
Vol 4 (3) ◽  
Author(s):  
Linxia Gu ◽  
Shijia Zhao ◽  
Aswini K. Muttyam ◽  
James M. Hammel

Two commercially available stents (the Palmaz–Schatz (PS) and S670 stents) with reported high and low restenosis rates, respectively, have been investigated in this paper. Finite element models simulating the stent, plaque, and artery interactions in 3 mm stenosed right coronary arteries were developed. These models were used to determine the stress field in artery walls after stent implantation. The material properties of porcine arteries were measured and implemented in the numerical models. The stress concentration induced in the artery by the PS stent was found to be more than double that of the S670 stent. It demonstrated a good correlation with the reported restenosis rate. The effects of stent structures, compliance mismatch, plaque geometry, and level of stenosis were studied. Results suggested that stent designs and tissue properties cause alterations in vascular anatomy that adversely affect arterial stress distributions within the wall, which impact vessel responses such as restenosis. Appropriate modeling of stent, plaque, and artery interactions provided insights for evaluating alterations to the arterial mechanical environment, as well as biomechanical factors leading to restenosis.


2020 ◽  
Vol 142 (5) ◽  
Author(s):  
Daniel L. Gillaugh ◽  
Alexander A. Kaszynski ◽  
Jeffrey M. Brown ◽  
Joseph A. Beck ◽  
Joseph C. Slater

Abstract Blade-mounted strain gages are vital during rig and engine development to ensure safe engine operation. However, they also enable a change in dynamics of integrally bladed rotors (IBRs). State-of-the-art IBR dynamic response predictions are accomplished using as-manufactured models (AMMs) generated via optical topography measurements and mesh morphing. Two AMM finite element models (FEMs) are created of a 20-bladed IBR. One FEM has no strain gages present, where the second FEM includes strain gages on six blades. Traditionally, strain gages and lead wires are treated as the same material property as the IBR itself. It will be shown that the inclusion of strain gages in AMM's using this method changes the IBR's predicted mistuning. An alternative AMM approach is developed that changes the material properties of the finite elements attributed to the strain gages. The predicted mistuning for each AMM is accomplished using the fundamental mistuning model identification (FMM ID), where the predicted mistuning will be compared to both traveling wave excitation (TWE) experiments and a rotating, single stage compressor rig. Findings show mistuning predictions of the nonstrain gaged AMM compare far better to the experiments compared to the inclusion of the strain gages in the AMM. Additionally, altering material properties of the strain gages in the AMM improve mistuning prediction compared to treating the strain gages as the parent IBR material. Therefore, AMM should be acquired using clean, nonstrain gaged rotors or the material properties of strain gaged elements need to be altered to more accurately model the component.


2003 ◽  
Vol 774 ◽  
Author(s):  
Janice L. McKenzie ◽  
Michael C. Waid ◽  
Riyi Shi ◽  
Thomas J. Webster

AbstractCarbon nanofibers possess excellent conductivity properties, which may be beneficial in the design of more effective neural prostheses, however, limited evidence on their cytocompatibility properties exists. The objective of the present in vitro study was to determine cytocompatibility and material properties of formulations containing carbon nanofibers to predict the gliotic scar tissue response. Poly-carbonate urethane was combined with carbon nanofibers in varying weight percentages to provide a supportive matrix with beneficial bulk electrical and mechanical properties. The substrates were tested for mechanical properties and conductivity. Astrocytes (glial scar tissue-forming cells) were seeded onto the substrates for adhesion. Results provided the first evidence that astrocytes preferentially adhered to the composite material that contained the lowest weight percentage of carbon nanofibers. Positive interactions with neurons, and, at the same time, limited astrocyte functions leading to decreased gliotic scar tissue formation are essential for increased neuronal implant efficacy.


2019 ◽  
Vol 24 (45) ◽  
pp. 5367-5374 ◽  
Author(s):  
Xiaoyun Li ◽  
Seyed M. Moosavi-Basri ◽  
Rahul Sheth ◽  
Xiaoying Wang ◽  
Yu S. Zhang

The role of endovascular interventions has progressed rapidly over the past several decades. While animal models have long-served as the mainstay for the advancement of this field, the use of in vitro models has become increasingly widely adopted with recent advances in engineering technologies. Here, we review the strategies, mainly including bioprinting and microfabrication, which allow for fabrication of biomimetic vascular models that will potentially serve to supplement the conventional animal models for convenient investigations of endovascular interventions. Besides normal blood vessels, those in diseased states, such as thrombosis, may also be modeled by integrating cues that simulate the microenvironment of vascular disorders. These novel engineering strategies for the development of biomimetic in vitro vascular structures will possibly enable unconventional means of studying complex endovascular intervention problems that are otherwise hard to address using existing models.


2018 ◽  
Vol 18 (2) ◽  
pp. 156-165 ◽  
Author(s):  
Jiaqiang Wang ◽  
Chien-shan Cheng ◽  
Yan Lu ◽  
Xiaowei Ding ◽  
Minmin Zhu ◽  
...  

Background: Propofol, a widely used intravenous anesthetic agent, is traditionally applied for sedation and general anesthesia. Explanation: Recent attention has been drawn to explore the effect and mechanisms of propofol against cancer progression in vitro and in vivo. Specifically, the proliferation-inhibiting and apoptosis-inducing properties of propofol in cancer have been studied. However, the underlying mechanisms remain unclear. Conclusion: This review focused on the findings within the past ten years and aimed to provide a general overview of propofol's malignance-modulating properties and the potential molecular mechanisms.


Lab on a Chip ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 795-820
Author(s):  
Andrea Spanu ◽  
Laura Martines ◽  
Annalisa Bonfiglio

This review focuses on the applications of organic transistors in cellular interfacing. It offers a comprehensive retrospective of the past, an overview of the latest innovations, and a glance on the future perspectives of this fast-evolving field.


1998 ◽  
Vol 22 ◽  
pp. 120-122
Author(s):  
A. S. Chaudhry

The need to develop an in vitro method to simulate ruminal digestion of protein foods has long been recognized. An in vitro method must be more rapid, consistent and convenient than in sacco methods. Purified enzymes have been examined in the past to estimate in vitro degradability of protein foods (Poos-Floyd et al., 1985; Aufrere et al., 1991; Luchini et al., 1996) or their fractions (Chaudhry and Webster, 1994). However, the selection of an appropriate enzyme for a range of foodstuffs remains to be realized. This study examined the potential of two enzymes and a centrifuged rumen fluid (CRF) to estimate proteolysis of food proteins.


Author(s):  
X. Lachenal ◽  
P. M. Weaver ◽  
S. Daynes

Conventional shape-changing engineering structures use discrete parts articulated around a number of linkages. Each part carries the loads, and the articulations provide the degrees of freedom of the system, leading to heavy and complex mechanisms. Consequently, there has been increased interest in morphing structures over the past decade owing to their potential to combine the conflicting requirements of strength, flexibility and low mass. This article presents a novel type of morphing structure capable of large deformations, simply consisting of two pre-stressed flanges joined to introduce two stable configurations. The bistability is analysed through a simple analytical model, predicting the positions of the stable and unstable states for different design parameters and material properties. Good correlation is found between experimental results, finite-element modelling and predictions from the analytical model for one particular example. A wide range of design parameters and material properties is also analytically investigated, yielding a remarkable structure with zero stiffness along the twisting axis.


Sign in / Sign up

Export Citation Format

Share Document