Aerosol Inhalation in the Rat Lung Part II: Theoretical Predictions of Particle Deposition Patterns

1995 ◽  
Vol 8 (1) ◽  
pp. 21-32 ◽  
Author(s):  
L. KOBLINGER ◽  
W. HOFMANN
2001 ◽  
Vol 435 ◽  
pp. 55-80 ◽  
Author(s):  
J. K. COMER ◽  
C. KLEINSTREUER ◽  
C. S. KIM

The flow theory and air flow structures in symmetric double-bifurcation airway models assuming steady laminar, incompressible flow, unaffected by the presence of aerosols, has been described in a companion paper (Part 1). The validated computer simulation results showed highly vortical flow fields, especially around the second bifurcations, indicating potentially complex particle distributions and deposition patterns. In this paper (Part 2), assuming spherical non-interacting aerosols that stick to the wall when touching the surface, the history of depositing particles is described. Specifically, the finite-volume code CFX (AEA Technology) with user-enhanced FORTRAN programs were validated with experimental data of particle deposition efficiencies as a function of the Stokes number for planar single and double bifurcations. The resulting deposition patterns, particle distributions, trajectories and time evolution were analysed in the light of the air flow structures for relatively low (ReD1 = 500) and high (ReD1 = 2000) Reynolds numbers and representative Stokes numbers, i.e. StD1 = 0.04 and StD1 = 0.12. Particle deposition patterns and surface concentrations are largely a function of the local Stokes number, but they also depend on the fluid–particle inlet conditions as well as airway geometry factors. While particles introduced at low inlet Reynolds numbers (e.g. ReD1 = 500) follow the axial air flow, secondary and vortical flows become important at higher Reynolds numbers, causing the formation of particle-free zones near the tube centres and subsequently elevated particle concentrations near the walls. Sharp or mildly rounded carinal ridges have little effect on the deposition efficiencies but may influence local deposition patterns. In contrast, more drastic geometric changes to the basic double-bifurcation model, e.g. the 90°-non-planar configuration, alter both the aerosol wall distributions and surface concentrations considerably.


ACS Nano ◽  
2018 ◽  
Vol 12 (8) ◽  
pp. 7771-7790 ◽  
Author(s):  
Wolfgang G. Kreyling ◽  
Winfried Möller ◽  
Uwe Holzwarth ◽  
Stephanie Hirn ◽  
Alexander Wenk ◽  
...  

2001 ◽  
Vol 90 (3) ◽  
pp. 1111-1118 ◽  
Author(s):  
W. Michael Foster ◽  
Dianne M. Walters ◽  
Malinda Longphre ◽  
Kristin Macri ◽  
Laura M. Miller

The objective of the study was to develop a scintigraphic method for measurement of airway mucociliary clearance in small laboratory rodents such as the mouse. Previous investigations have characterized the secretory cell types present in the mouse airway, but analysis of the mucus transport system has been limited to in vitro examination of tissue explants or invasive in vivo measures of a single airway, the trachea. Three methods were used to deposit insoluble, radioisotopic colloidal particles: oropharyngeal aspiration, intratracheal instillation, and nose-only aerosol inhalation. The initial distribution of particles within the lower respiratory tract was visualized by γ-camera, and clearance of particles was followed intermittently over 6 h and at the conclusion, 24 h postdelivery. Subsets of mice underwent lavage for evidence of tissue inflammation, and others were restudied for reproducibility of the methods. The aspiration and instillation methods of delivery led to greater distributions of deposited activity within the lungs, i.e., ∼60–80% of the total respiratory tract radioactivity, whereas the nose-only aerosol technique attained a distribution of 32% to the lungs. However, the aerosol technique maximized the fraction of particles that cleared the airway over a 24-h period, i.e, deposited onto airway epithelial surfaces and cleared by mucociliary function such that lung retention at 24 h averaged 57% for delivery by aerosol inhalation and ≥80% for the aspiration or intratracheal instillation techniques. Particle delivery methods did not cause lung inflammation/injury with use of inflammatory cells and chemoattractant cytokines as criteria. Scintigraphy can discern particle deposition and clearance from the lower respiratory tract in the mouse, is noninvasive and reproducible, and includes the capability for restudy and lung lavage when time course or chronic treatments are being considered.


Author(s):  
Husam Osman ◽  
Kazimierz Adamiak ◽  
G. S. Peter Castle ◽  
Hua-Tzu (Charles) Fan ◽  
Joseph Simmer

In this paper, a full 3D numerical model using ANSYS commercial software has been created to simulate the particle deposition profile for stationary and moving flat targets, assuming multiple injections of charged poly-dispersed particles. Different injection angles along three virtual rings were assumed to form a shower injection pattern. The experimental and the numerical results of deposition thickness have been presented and compared for different injection patterns. It has been found that there are some parameters, such as the total number of injection points, the radii of the rings and the fractional mass flow rate in each injection ring, which affect the numerical results of the deposition thickness and uniformity.


1988 ◽  
Vol 31 (6) ◽  
pp. 39-41
Author(s):  
Frank Stratmann ◽  
Heinz Fissan ◽  
Thomas Peterson

A series of two-dimensional calculations are performed to determine particle fluxes to wafers in a stagnation flow configuration. Mechanisms that influenced particle deposition included convection, diffusion, sedimentation, and thermophoresis. Particle deposition patterns resulting from a uniform freestream concentration are compared with deposition patterns from a narrow particle beam.


Sign in / Sign up

Export Citation Format

Share Document