scholarly journals Comparison of the TriTrac-R3D accelerometer and a self-report activity diary with heart-rate monitoring for the assessment of energy expenditure in children

2002 ◽  
Vol 87 (6) ◽  
pp. 623-631 ◽  
Author(s):  
G. Rodriguez ◽  
L. Béghin ◽  
L. Michaud ◽  
L. A. Moreno ◽  
D. Turck ◽  
...  

Determining total energy expenditure (EE) in children under free-living conditions has become of increasingly clinical interest. The aim of this study was to compare three different methods to assess EE triaxial accelerometry (TriTrac-R3D; Professional Products, Division of Reining International, Madison, WI, USA), activity diary and heart-rate (HR) monitoring combined with indirect calorimetry (IC). Twenty non-obese children and adolescents, aged 5.5 to 16.0 years, participated in this study. Results from the three methods were collected simultaneously under free-living conditions during the same 24 h schoolday period. Neither activity diary (5904 (SD 1756) KJ) NOR THE TRITRAC-R3D (6389 (sd 979) kJ) showed statistical differences in 24 h total EE compared with HR monitoring (5965 (sd 1911) kJ). When considering different physical activity (PA) periods, compared with HR monitoring, activity diary underestimates total EE during sedentary periods (P<0·001) and overestimates total EE and PA-EE during PA periods (P<0·001) because of the high energy cost equivalence of activity levels. The TriTrac-R3D, compared with HR monitoring, shows good agreement for assessing PA-EE during PA periods (mean difference +0·25 (sd 1·9) kJ/min; 95 % CI for the bias -0·08, 0·58), but underestimates PA-EE and it does not show good precision during sedentary periods (-0·87 (sd 1·4) kJ/min, P<0·001). Correlation between the vector magnitude generated by the TriTrac-R3D accelerometer and EE of activities derived from HR monitoring is high. When compared with the HR method, the TriTrac-R3D and activity diary are not systematically accurate and must be carefully used for the assessment of children's EE depending on the purpose of each study.

1997 ◽  
Vol 78 (5) ◽  
pp. 709-722 ◽  
Author(s):  
Beatrice Morio ◽  
Patrick Ritz ◽  
Elisabeth Verdier ◽  
Christophe Montaurier ◽  
Bernard Beaufrere ◽  
...  

The aim of the present study was to validate against the doubly-labelled water (DLW) technique the factorial method and the heart rate (HR) recording method for determining daily energy expenditure (DEE) of elderly people in free-living conditions. The two methods were first calibrated and validated in twelve healthy subjects (six males and six females; 70·1 (sd 2·7) years) from opencircuit whole-body indirect calorimetry measurements during three consecutive days and during 1 d respectively. Mean energy costs of the various usual activities were determined for each subject using the factorial method, and individual relationships were set up between HR and energy expenditure for the HR recording method. In free-living conditions, DEE was determined over the same period of time by the DLW, the factorial and the HR recording methods during 17, 14 and 4 d respectively. Mean free-living DEE values for men estimated using the DLW, the factorial and the HR recording methods were 12·8 (sd 3·1), 12·7 (sd 2·2) and 13·5 (sd 2·7) MJ/d respectively. Mean free-living DEE values for women were 9·6 (sd 0·8), 8·8 (sd 1·2) and 10·2 (sd 1·5) MJ/d respectively. No significant differences were found between the three methods for either sex, using the Bland & Altman (1986) test. Mean differences in DEE of men were -0·9 (sd 11·8) % between the factorial and DLW methods, and +4·7 (sd 16·1) % between the HR recording and DLW methods. Similarly, in women, mean differences were -7·7 (sd 12·7) % between the factorial and DLW methods, and +5·9 (sd 8·8) % between the HR recording and DLW methods. It was concluded that the factorial and the HR recording methods are satisfactory alternatives to the DLW method when considering the mean DEE of a group of subjects. Furthermore, mean energy costs of activities calculated in the present study using the factorial method were shown to be suitable for determining free-living DEE of elderly people when the reference value (i.e. sleeping metabolic rate) is accurately measured.


2020 ◽  
Vol 3 (2) ◽  
pp. 170-185 ◽  
Author(s):  
Kelly R. Evenson ◽  
Camden L. Spade

Purpose: A systematic review to summarize the validity and reliability of steps, distance, energy expenditure, speed, elevation, heart rate, and sleep assessed by Garmin activity trackers. Methods: Searches included studies published through December 31, 2018. Correlation coefficients (CC) were assessed as low (<0.60), moderate (0.60 to <0.75), good (0.75 to <0.90), or excellent (≥0.90). Mean absolute percentage errors (MAPE) were assessed as acceptable at <5% in controlled conditions and <10% for free-living conditions. Results: Overall, 32 studies of adults documented validity. Four of these studies also documented reliability. The sample size ranged from 1–95 for validity and 4–31 for reliability testing. Step inter- and intra-reliability was good-to-excellent and speed intra-reliability was excellent. No other features were explored for reliability. Step validity, across 16 studies, generally indicated good-to-excellent CC and acceptable MAPE. Distance validity, tested in three studies, generally indicated poor CC and MAPE that exceeded acceptable limits, with both over and underestimation. Energy expenditure validity, across 12 studies, generally indicated wide variability in CC and MAPE that exceeded acceptable limits. Heart rate validity in five studies had low-to-excellent CC and all MAPE exceeded acceptable limits. Speed, elevation, and sleep validity were assessed in only one or two studies each; for sleep, the criterion relied on self-report rather than polysomnography. Conclusion: This systematic review of Garmin activity trackers among adults indicated higher validity of steps; few studies on speed, elevation, and sleep; and lower validity for distance, energy expenditure, and heart rate. Intra- and inter-device feature reliability needs further testing.


2000 ◽  
Vol 84 (4) ◽  
pp. 531-539 ◽  
Author(s):  
Jérôme Ribeyre ◽  
Nicole Fellmann ◽  
Jean Vernet ◽  
Michel Delaître ◽  
Alain Chamoux ◽  
...  

The objectives of the study were to determine: (1) daily energy expenditure (EE) of athletic and non-athletic adolescents of both sexes in free-living conditions; (2) day-to-day variations in daily EE during 1 week; (3) energy costs of the main activities; and (4) the effect of usual activity on EE during sleep, seated and miscellaneous activities. Fifty adolescents (four groups of eleven to fifteen boys or girls aged 16–19 years) participated in the study. Body composition was measured by the skinfold-thickness method, and VO2max and external mechanical power (EMP) by a direct method (respiratory gas exchanges) on a cycloergometer. Daily EE and partial EE in free-living conditions were computed from heart-rate (HR) recordings during seven consecutive days using individual prediction equations established from the data obtained during a 24 h period spent in whole-body calorimeters with similar activities. Fat-free mass (FFM), VO2max, EMP, daily EE and EE during sleep were significantly higher in athletic than in non-athletic subjects. After adjustment for FFM, VO2max, EMP, daily EE and EE during exercise were still higher in athletic than in non-athletic adolescents (P<0·001). However, adjusted sleeping EE was not significantly different between athletic and non-athletic adolescents. Increases in exercise EE were partly compensated for by significant reductions in EE during schoolwork and miscellaneous activities. Thus, the differences in daily EE between athletic and non-athletic subjects resulted mainly from increases in FFM and EE during exercise (duration and energy cost).


2012 ◽  
Vol 113 (11) ◽  
pp. 1763-1771 ◽  
Author(s):  
C. Villars ◽  
A. Bergouignan ◽  
J. Dugas ◽  
E. Antoun ◽  
D. A. Schoeller ◽  
...  

Combining accelerometry (ACC) with heart rate (HR) monitoring is thought to improve activity energy expenditure (AEE) estimations compared with ACC alone to evaluate the validity of ACC and HR used alone or combined. The purpose of this study was to estimate AEE in free-living conditions compared with doubly labeled water (DLW). Ten-day free-living AEE was measured by a DLW protocol in 35 18- to 55-yr-old men (11 lean active; 12 lean sedentary; 12 overweight sedentary) wearing an Actiheart (combining ACC and HR) and a RT3 accelerometer. AEE was estimated using group or individual calibration of the HR/AEE relationship, based on an exercise-tolerance test. In a subset ( n = 21), AEE changes (ΔAEE) were measured after 1 mo of detraining (active subjects) or an 8-wk training (sedentary subjects). Actiheart-combined ACC/HR estimates were more accurate than estimates from HR or ACC alone. Accuracy of the Actiheart group-calibrated ACC/HR estimates was modest [intraclass correlation coefficient (ICC) = 0.62], with no bias but high root mean square error (RMSE) and limits of agreement (LOA). The mean bias of the estimates was reduced by one-third, like RMSE and LOA, by individual calibration (ICC = 0.81). Contrasting with group-calibrated estimates, the Actiheart individual-calibrated ACC/HR estimates explained 40% of the variance of the DLW-ΔAEE (ICC = 0.63). This study supports a good level of agreement between the Actiheart ACC/HR estimates and DLW-measured AEE in lean and overweight men with varying fitness levels. Individual calibration of the HR/AEE relationship is necessary for AEE estimations at an individual level rather than at group scale and for ΔAEE evaluation.


2013 ◽  
Vol 2 ◽  
Author(s):  
Marie Löf ◽  
Hanna Henriksson ◽  
Elisabet Forsum

AbstractActivity energy expenditure (AEE) during free-living conditions can be assessed using devices based on different principles. To make proper comparisons of different devices' capacities to assess AEE, they should be evaluated in the same population. Thus, in the present study we evaluated, in the same group of subjects, the ability of three devices to assess AEE in groups and individuals during free-living conditions. In twenty women, AEE was assessed using RT3 (three-axial accelerometry) (AEERT3), Actiheart (a combination of heart rate and accelerometry) (AEEActi) and IDEEA (a multi-accelerometer system) (AEEIDEEA). Reference AEE (AEEref) was assessed using the doubly labelled water method and indirect calorimetry. Average AEEActi was 5760 kJ per 24 h and not significantly different from AEEref (5020 kJ per 24 h). On average, AEERT3 and AEEIDEEA were 2010 and 1750 kJ per 24 h lower than AEEref, respectively (P < 0·001). The limits of agreement (± 2 sd) were 2940 (Actiheart), 1820 (RT3) and 2650 (IDEEA) kJ per 24 h. The variance for AEERT3 was lower than for AEEActi (P = 0·006). The RT3 classified 60 % of the women in the correct activity category while the corresponding value for IDEEA and Actiheart was 30 %. In conclusion, the Actiheart may be useful for groups and the RT3 for individuals while the IDEEA requires further development. The results are likely to be relevant for a large proportion of Western women of reproductive age and demonstrate that the procedure selected to assess physical activity can greatly influence the possibilities to uncover important aspects regarding interactions between physical activity, diet and health.


1997 ◽  
Vol 37 (3) ◽  
pp. 358-359
Author(s):  
B. Morio ◽  
P. Ritz ◽  
E. Verdier ◽  
C. Montaurier ◽  
Y. Boirie ◽  
...  

2017 ◽  
Vol 5 (10) ◽  
pp. e157 ◽  
Author(s):  
Alexander Wilhelm Gorny ◽  
Seaw Jia Liew ◽  
Chuen Seng Tan ◽  
Falk Müller-Riemenschneider

2008 ◽  
Vol 20 (2) ◽  
pp. 181-197 ◽  
Author(s):  
David Xiaoqian Sun ◽  
Gordon Schmidt ◽  
Sock Miang Teo-Koh

This is a validation study of the RT3 accelerometer for measuring physical activities of children in simulated free-living conditions. Twenty-five children age 12–14 years completed indoor testing, and 18 of them completed outdoor testing. Activity counts from the RT3 accelerometer estimated activity energy expenditure (AEE) and the Cosmed K4b2 analyzer measured oxygen uptake. Correlations were found between activity counts and metabolic cost (r = .95, p < .001), metabolic cost and RT3 estimated AEE (r = .96, p < .001) in the indoor test, activity counts and RT3 estimated AEE (r = .97, p < .001) in the outdoor test, and activity counts and metabolic cost when all activities were combined (r = .77, p < .001). Results indicate that the RT3 accelerometer might be used to provide acceptable estimates of free-living physical activity in children.


2008 ◽  
Vol 101 (3) ◽  
pp. 446-456 ◽  
Author(s):  
Corby K. Martin ◽  
Hongmei Han ◽  
Sandra M. Coulon ◽  
H. Raymond Allen ◽  
Catherine M. Champagne ◽  
...  

The aim of the present study was to report the first reliability and validity tests of the remote food photography method (RFPM), which consists of camera-enabled cell phones with data transfer capability. Participants take and transmit photographs of food selection and plate waste to researchers/clinicians for analysis. Following two pilot studies, adult participants (n 52; BMI 20–35 kg/m2 inclusive) were randomly assigned to the dine-in or take-out group. Energy intake (EI) was measured for 3 d. The dine-in group ate lunch and dinner in the laboratory. The take-out group ate lunch in the laboratory and dinner in free-living conditions (participants received a cooler with pre-weighed food that they returned the following morning). EI was measured with the RFPM and by directly weighing foods. The RFPM was tested in laboratory and free-living conditions. Reliability was tested over 3 d and validity was tested by comparing directly weighed EI to EI estimated with the RFPM using Bland–Altman analysis. The RFPM produced reliable EI estimates over 3 d in laboratory (r 0·62; P < 0·0001) and free-living (r 0·68; P < 0·0001) conditions. Weighed EI correlated highly with EI estimated with the RFPM in laboratory and free-living conditions (r>0·93; P < 0·0001). In two laboratory-based validity tests, the RFPM underestimated EI by − 4·7 % (P = 0·046) and − 5·5 % (P = 0·076). In free-living conditions, the RFPM underestimated EI by − 6·6 % (P = 0·017). Bias did not differ by body weight or age. The RFPM is a promising new method for accurately measuring the EI of free-living individuals. Error associated with the method is small compared with self-report methods.


Sign in / Sign up

Export Citation Format

Share Document