A Multiscale Filtering Explanation of Gradient Induction and Remote Brightness Induction Effects: A Reply to Logvinenko (2003)

Perception ◽  
2005 ◽  
Vol 34 (7) ◽  
pp. 793-802 ◽  
Author(s):  
Barbara Blakeslee ◽  
Mark E McCourt

Grating induction is a brightness effect in which a counterphase spatial brightness variation (a grating) is induced in a homogeneous test strip that is surrounded by an inducing luminance grating (McCourt, 1982 Vision Research22 119–134). Moulden and Kingdom (1991 Vision Research31 1999–2008) introduced an interesting variant of grating induction (sometimes referred to as gradient induction) in which multiple strips of either a linear luminance ramp or a sine-wave grating were interlaced with strips of homogeneous luminance. We (Blakeslee and McCourt, 1999 Vision Research39 4361–4377) demonstrated that a simple multiscale filtering explanation could account for grating induction. Recently, however, Logvinenko (2003 Perception32 621–626) presented several arguments impugning the adequacy of spatial filtering approaches to understanding brightness induction in gradient induction stimuli. We propose that Logvinenko's arguments apply only to a limited class of filtering models, specifically those which employ only a single spatial filter. To test this hypothesis we modeled gradient induction stimuli as a function of inducing contrast, as well as Logvinenko's (2003) remote induction stimulus, using our multiscale oriented difference-of-Gaussians (ODOG) model (Blakeslee and McCourt 1999). The ODOG model successfully predicts the appearance of the inducing strips and the homogeneous test strips in the gradient induction stimuli and the appearance of the test patches in the remote induction stimuli. These results refute Logvinenko's (2003) claims, and we interpret them as providing strong evidence for a multiscale filtering approach to understanding both gradient induction and remote brightness induction effects.

Contrast sensitivity as a function of spatial frequency was determined for 138 neurons in the foveal region of primate striate cortex. The accuracy of three models in describing these functions was assessed by the method of least squares. Models based on difference-of-Gaussians (DOG) functions were shown to be superior to those based on the Gabor function or the second differential of a Gaussian. In the most general case of the DOG models, each subregion of a simple cell’s receptive field was constructed from a single DOG function. All the models are compatible with the classical observation that the receptive fields of simple cells are made up of spatially discrete ‘on’ and ‘off’ regions. Although the DOG-based models have more free parameters, they can account better for the variety of shapes of spatial contrast sensitivity functions observed in cortical cells and, unlike other models, they provide a detailed description of the organization of subregions of the receptive field that is consistent with the physiological constraints imposed by earlier stages in the visual pathway. Despite the fact that the DOG-based models have spatially discrete components, the resulting amplitude spectra in the frequency domain describe complex cells just as well as simple cells. The superiority of the DOG-based models as a primary spatial filter is discussed in relation to popular models of visual processing that use the Gabor function or the second differential of a Gaussian.


EDIS ◽  
1969 ◽  
Vol 2003 (17) ◽  
Author(s):  
Kenneth R. Berger ◽  
Matthew Knoelke ◽  
Bruce Welt

Sample preparation can greatly influence the results of laboratory testing of packaging sealant strength. Factors such as test strip width, edge uniformity, sealing die temperature and die load are recognizable variables to control. A design of experiments approach was used to explore the rank importance of these factors and any interactive effects that may occur. A generally well-behaved ethylene vinyl acetate (EVA) sealant on a high density polyethylene (HDPE) film was used for these tests. Experimental results indicate that sample width, die temperature and die pressure are the most influential factors. Unexpectedly, edge effects, namely a regular sine wave pattern and a generally random irregular edge had little influence on hot tack results. This document is ABE340, one of a series of the Agricultural and Biological Engineering Department, Florida Cooperative Extension Service, Institute of Food and Agricultural Sciences, University of Florida. First published December 2002.  https://edis.ifas.ufl.edu/ae211


Author(s):  
David A. Ansley

The coherence of the electron flux of a transmission electron microscope (TEM) limits the direct application of deconvolution techniques which have been used successfully on unmanned spacecraft programs. The theory assumes noncoherent illumination. Deconvolution of a TEM micrograph will, therefore, in general produce spurious detail rather than improved resolution.A primary goal of our research is to study the performance of several types of linear spatial filters as a function of specimen contrast, phase, and coherence. We have, therefore, developed a one-dimensional analysis and plotting program to simulate a wide 'range of operating conditions of the TEM, including adjustment of the:(1) Specimen amplitude, phase, and separation(2) Illumination wavelength, half-angle, and tilt(3) Objective lens focal length and aperture width(4) Spherical aberration, defocus, and chromatic aberration focus shift(5) Detector gamma, additive, and multiplicative noise constants(6) Type of spatial filter: linear cosine, linear sine, or deterministic


1981 ◽  
Vol 64 (9) ◽  
pp. 113-120
Author(s):  
Kohji Takemura ◽  
Suteo Tsutsumi

2021 ◽  
Vol 35 (1) ◽  
pp. 35-42
Author(s):  
José Luis Marcos ◽  
Azahara Marcos

Abstract. The aim of this study was to determine if contingency awareness between the conditioned (CS) and unconditioned stimulus (US) is necessary for concurrent electrodermal and eyeblink conditioning to masked stimuli. An angry woman’s face (CS+) and a fearful face (CS−) were presented for 23 milliseconds (ms) and followed by a neutral face as a mask. A 98 dB noise burst (US) was administered 477 ms after CS+ offset to elicit both electrodermal and eyeblink responses. For the unmasking conditioning a 176 ms blank screen was inserted between the CS and the mask. Contingency awareness was assessed using trial-by-trial ratings of US-expectancy in a post-conditioning phase. The results showed acquisition of differential electrodermal and eyeblink conditioning in aware, but not in unaware participants. Acquisition of differential eyeblink conditioning required more trials than electrodermal conditioning. These results provided strong evidence of the causal role of contingency awareness on differential eyeblink and electrodermal conditioning.


2009 ◽  
Author(s):  
Navin Viswanathan ◽  
James S. Magnuson ◽  
Carol A. Fowler
Keyword(s):  