scholarly journals A setup for Seebeck coefficient measurement through controlled heat pulses

2019 ◽  
Vol 90 (11) ◽  
pp. 116101 ◽  
Author(s):  
Abdul Ahad ◽  
D. K. Shukla
Author(s):  
Weihe Xu ◽  
Qi Chen ◽  
Yong Shi ◽  
Hamid Hadim

The P-type perovskite oxides La1-xSrxCoO3 are a promising group of complex oxide thermoelectric (TE) materials because of its a higher Seebeck coefficient. In this paper, the La0.95Sr0.05CoO3 thin film was prepared by spin coating. A custom-made MEMS (micro-electromechanical system) based device was used to measure the voltage output and Seebeck coefficient of the thin film. The measured Seebeck coefficient of the thin film was 350 μV/K.