In situ chamber built for clarifying the relationship between methane hydrate crystal morphology and gas permeability in a thin glass micromodel cell

2017 ◽  
Vol 88 (6) ◽  
pp. 064503 ◽  
Author(s):  
Michihiro Muraoka ◽  
Yoshitaka Yamamoto
Author(s):  
O.L. Krivanek ◽  
G.J. Wood

Electron microscopy at 0.2nm point-to-point resolution, 10-10 torr specimei region vacuum and facilities for in-situ specimen cleaning presents intere; ing possibilities for surface structure determination. Three methods for examining the surfaces are available: reflection (REM), transmission (TEM) and profile imaging. Profile imaging is particularly useful because it giv good resolution perpendicular as well as parallel to the surface, and can therefore be used to determine the relationship between the surface and the bulk structure.


Author(s):  
Kun Lee ◽  
Jingyi Si ◽  
Ricai Han ◽  
Wei Zhang ◽  
Bingbing Tan ◽  
...  

There are more supports for the view that human papillomavirus (HPV) infection might be an etiological factor in the development of cervical cancer when the association of persistent condylomata is considered. Biopsies from 318 cases with squamous cell carcinoma of uterine cervix, 48 with cervical and vulvar condylomata, 14 with cervical intraepithelial neoplasia (CIN), 34 with chronic cervicitis and 24 normal cervical epithelium were collected from 5 geographic regions of China with different cervical cancer mortalities. All specimens were prepared for Dot blot, Southern blot and in situ DNA-DNA hybridizations by using HPV-11, 16, 18 DNA labelled with 32P and 3H as probes to detect viral homologous sequences in samples. Among them, 32 cases with cervical cancer, 27 with condyloma and 10 normal cervical epitheliums were randomly chosen for comparative EM observation. The results showed that: 1), 192 out of 318 (60.4%) cases of cervical cancer were positive for HPV-16 DNA probe (Table I)


Author(s):  
Shotaro Tada ◽  
Norifumi Asakuma ◽  
Shiori Ando ◽  
Toru Asaka ◽  
Yusuke Daiko ◽  
...  

This paper reports on the relationship between the H2 chemisorption properties and reversible structural reorientation of the possible active site around Al formed in-situ within polymer-derived ceramics (PDCs) based on...


Agronomy ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 938
Author(s):  
Ladislav Menšík ◽  
Lukáš Hlisnikovský ◽  
Pavel Nerušil ◽  
Eva Kunzová

The aim of the study was to compare the concentrations of risk elements (As, Cu, Mn, Ni, Pb, Zn) in alluvial soil, which were measured by a portable X-ray fluorescence analyser (pXRF) in situ (FIELD) and in the laboratory (LABORATORY). Subsequently, regression equations were developed for individual elements through the method of construction of the regression model, which compare the results of pXRF with classical laboratory analysis (ICP-OES). The accuracy of the measurement, expressed by the coefficient of determination (R2), was as follows in the case of FIELD–ICP-OES: Pb (0.96), Zn (0.92), As (0.72), Mn (0.63), Cu (0.31) and Ni (0.01). In the case of LABORATORY–ICP-OES, the coefficients had values: Pb (0.99), Zn (0.98), Cu and Mn (0.89), As (0.88), Ni (0.81). A higher dependence of the relationship was recorded between LABORATORY–ICP-OES than between FIELD–ICP-OES. An excellent relationship was recorded for the elements Pb and Zn, both for FIELD and LABORATORY (R2 higher than 0.90). The elements Cu, Mn and As have a worse tightness in the relationship; however, the results of the model have shown its applicability for common use, e.g., in agricultural practice or in monitoring the quality of the environment. Based on our results, we can say that pXRF instruments can provide highly accurate results for the concentration of risk elements in the soil in real time for some elements and meet the principle of precision agriculture: an efficient, accurate and fast method of analysis.


Sensors ◽  
2021 ◽  
Vol 21 (15) ◽  
pp. 5090
Author(s):  
Qingsheng Liu ◽  
Jinjia Guo ◽  
Wangquan Ye ◽  
Kai Cheng ◽  
Fujun Qi ◽  
...  

As a powerful in situ detection technique, Raman spectroscopy is becoming a popular underwater investigation method, especially in deep-sea research. In this paper, an easy-to-operate underwater Raman system with a compact design and competitive sensitivity is introduced. All the components, including the optical module and the electronic module, were packaged in an L362 × Φ172 mm titanium capsule with a weight of 20 kg in the air (about 12 kg in water). By optimising the laser coupling mode and focusing lens parameters, a competitive sensitivity was achieved with the detection limit of SO42− being 0.7 mmol/L. The first sea trial was carried out with the aid of a 3000 m grade remotely operated vehicle (ROV) “FCV3000” in October 2018. Over 20,000 spectra were captured from the targets interested, including methane hydrate, clamshell in the area of cold seep, and bacterial mats around a hydrothermal vent, with a maximum depth of 1038 m. A Raman peak at 2592 cm−1 was found in the methane hydrate spectra, which revealed the presence of hydrogen sulfide in the seeping gas. In addition, we also found sulfur in the bacterial mats, confirming the involvement of micro-organisms in the sulfur cycle in the hydrothermal field. It is expected that the system can be developed as a universal deep-sea survey and detection equipment in the near future.


1999 ◽  
Vol 54 (12) ◽  
pp. 1849-1858 ◽  
Author(s):  
J.M. Herri ◽  
F. Gruy ◽  
J.S. Pic ◽  
M. Cournil ◽  
B. Cingotti ◽  
...  
Keyword(s):  

1998 ◽  
Vol 6 (5) ◽  
pp. 409-424 ◽  
Author(s):  
M. Yanaka ◽  
T. Miyamoto ◽  
Y. Tsukahara ◽  
Nobuo Takeda

Sign in / Sign up

Export Citation Format

Share Document