scholarly journals High performance mid-temperature selective absorber based on titanium oxides cermet deposited by direct current reactive sputtering of a single titanium target

2016 ◽  
Vol 119 (4) ◽  
pp. 045102 ◽  
Author(s):  
Lu Tang ◽  
Feng Cao ◽  
Yang Li ◽  
Jiming Bao ◽  
Zhifeng Ren
2000 ◽  
Vol 6 (S2) ◽  
pp. 226-227
Author(s):  
Duarte-Moller A. ◽  
F. Espinosa-Maganña ◽  
R. Martínez-S´anchez ◽  
O. Contreras

Titanium nitride coatings were grown in a physical vapor deposition system assisted by a direct current reactive magnetron sputtering technique. The vacuum chamber was evacuated with a mechanical pump and cryopump to a base pressure of 10-7 Torr. The Sputtering was performed with a direct current high voltage source (0-1 Kev and 1 A) on a titanium target (99.98% purity). The titanium target was sputtered with a high purity argon -nitrogen mixture. The films were deposited on monocrystalline silicon (mc-Si) (111) substrates at different nitrogen partial pressures from 0.08 mTorr to 1.5 mTorr. Total pressure, power applied to target and substrate temperature were keep constant in all the experiments.EXEELFS analysis were done using the standard procedure [1,2]. In this case, we are find that the atomic concentration is in good agreement with the respective established stoichioinetry N/T=0.99. Figure 1 shows the window of high energy loss where appears their respective N K-edge and Ti -L23.


2006 ◽  
Vol 502 (1-2) ◽  
pp. 15-21 ◽  
Author(s):  
S.J. Nadel ◽  
P. Greene ◽  
J. Rietzel ◽  
M. Perata ◽  
L. Malaszewski ◽  
...  

2014 ◽  
Vol 30 (7) ◽  
pp. 455-459 ◽  
Author(s):  
X.X. Zhao ◽  
G.Y. Wei ◽  
X.F. Meng ◽  
A. Zhang

1985 ◽  
Vol 39 (6) ◽  
pp. 960-968 ◽  
Author(s):  
Ira S. Krull ◽  
Kenneth W. Panaro

Total tin determinations can be accomplished at trace levels (10–25 ppb) by a continuous on-line hydride generation (HY), followed by direct current plasma (DCP) emission spectroscopy (HY-DCP). This approach is applicable for organotin compounds such as mono-, di-, and trimethyltin chloride, as well as stannous and stannic cations. HY-DCP methods of total tin analysis have been applied to a number of spiked and actual samples. Detection limits, calibration plots, sensitivities, and related analytical parameters have been evaluated. Organotin analysis and speciation can be accomplished by the interfacing of this HY-DCP step with high-performance liquid chromatography (HPLC), with the use of a polymeric PRP-1 type column with an acidic, ionic mobile phase, usually containing a suitable ion-pairing reagent. The overall speciation approach, HPLC-HY-DCP, has been evaluated with regard to separation conditions; detection limits; sensitivities; calibration plots; and applications to spiked water, clam juice, seawater, and tuna fish samples. The results suggest the suitability and reliability of this HPLC-HY-DCP approach for individual tin species. Other metal species capable of forming a hydride derivative on-line, in a continuous fashion, may also be suitable for speciation by HPLC-HY-DCP.


1992 ◽  
Vol 71 (10) ◽  
pp. 5173-5182 ◽  
Author(s):  
C. D. Tsiogas ◽  
J. N. Avaritsiotis

2015 ◽  
Author(s):  
M. Sato ◽  
M.B. Takeyama ◽  
Y. Nakata ◽  
Y. Kobayashi ◽  
T. Nakamura ◽  
...  

Author(s):  
Jianyong Yao ◽  
Zongxia Jiao ◽  
Dawei Ma

High accuracy tracking control of direct current (DC) motors is concerned in this paper. A continuously differentiable friction model is adopted to account for the friction nonlinearities, which allows more flexible and suitable practical implementation. Since only output signal is available for measurement, an extended state observer (ESO) is designed to provide precise estimates of the unmeasurable state together with external disturbances, which facilitates the controller design without any transformations. The global stability of the controller is ensured via a certain robust feedback law. The resulting controller theoretically guarantees a prescribed tracking performance in general, while achieving asymptotic output tracking in the absence of time-varying disturbances, which is very important for high accuracy control of motion systems. Comparative experimental results are obtained to verify the high-performance nature of the proposed control strategy.


Sign in / Sign up

Export Citation Format

Share Document