Load resilient transmission line system for long-pulse, high-power ICRF operation at KSTAR

2014 ◽  
Author(s):  
H. J. Kim ◽  
S. J. Wang ◽  
Y. S. Bae ◽  
H. L. Yang ◽  
J. G. Kwak ◽  
...  
2015 ◽  
Vol 96-97 ◽  
pp. 498-502 ◽  
Author(s):  
Hae Jin Kim ◽  
Son Jong Wang ◽  
Byoung Ho Park ◽  
Jong-Gu Kwak ◽  
Julien Hillairet ◽  
...  

2021 ◽  
Author(s):  
Takayuki Kobayashi ◽  
Hibiki Yamazaki ◽  
Shinichi Hiranai ◽  
Masayuki Sawahata ◽  
Masayuki Terakado ◽  
...  

Abstract A gyrotron and a matching optics unit (MOU) for the multi-frequency electron cyclotron heating and current drive (ECH/CD) system in JT-60SA have been developed successfully. The gyrotron demonstrated stable operation at high powers of 1.5 MW for 5 s and 1.9 MW for 1 s at 110 GHz. To obtain high HE11 mode purity (> 90%) at the outlet of the waveguide in the ECH/CD launcher, a MOU for operating at three frequencies of 82 GHz, 110 GHz, and 138 GHz that includes three pairs of water-cooled phase correcting mirrors has been developed, which allows the mirrors to be changed without opening the evacuated MOU. The mode purity at the inlet of a dummy load in the transmission line was evaluated at high-power and an HE11 mode purity of > 90% was obtained at three frequencies.


1993 ◽  
Vol 71 (13) ◽  
pp. 2018-2021 ◽  
Author(s):  
S. Alberti ◽  
B. G. Danly ◽  
G. Gulotta ◽  
E. Giguet ◽  
T. Kimura ◽  
...  

2018 ◽  
Vol 12 (3) ◽  
pp. 124-130
Author(s):  
Erol Can

This article deals with the energy transmission line system which feeds from solar energy at the MATLAB Simulink. So, direct voltage is considered to be converted as an alternating voltage by a 35-level inverter after the solar power plant which has the power of 110 MW an produce 360 kV of direct voltage. A line which covers 240 km of distance is preferred to transmit electrical power from the A1 point to an A2 point. Due to this, the required mathematical equations are calculated with a circuit analyzing method for the line modeling in the simulation. Experiments on the model are carried out at the MATLAB Simulink after the creation of an energy transmission line. After that, when measurements are made taking into consideration the A2 node; the capacitor voltage, the transformer current, the A2 node current, and the fault current, values are given according to the converted voltage at the frequencies of 100 Hz, 80 Hz, and 50 Hz. The obtained results demonstrate the success of the proposed line system, while power is distributed with eliminated fault at a long distance at different frequencies.


1984 ◽  
Vol 53 (18) ◽  
pp. 1728-1731 ◽  
Author(s):  
J. A. Pasour ◽  
R. F. Lucey ◽  
C. A. Kapetanakos

2019 ◽  
Vol 66 (1) ◽  
pp. 722-728 ◽  
Author(s):  
Zhenbang Liu ◽  
Hua Huang ◽  
Xiao Jin ◽  
Shifeng Li ◽  
Tengfang Wang ◽  
...  

Author(s):  
Arsal Mehmood ◽  
Huzaifa Hassan ◽  
Faraz Ahmed Baig ◽  
Suhail Ahmed Shaikh

Researchers are working on techniques to mitigate failure rates as low as possible to avoid potential harm, sustain high power efficiency for this a considerable number of estimation studies were already performed and several designs of methodologies were being suggested. The transmission line performs the role of the arteries which maintain the process of transporting electricity in the transmission line. That is why it is important to maintain and manage the costs of these tracks.  Surge arrestor and shield wire application are often techniques chosen for defensive strategy in a very technique. By pushing travelling waves towards the electrical equipment mounted on the transmission line, the effects of lightning stoke on the transmission line may cause severe damage to the electrical equipment. In this review, this research study provides a review-based overview of the mechanism of occurrence of lightning along with its impact on the transmission line and the defence methods used to prevent such effects. A MATLAB / SIMULINK 2020a simulation modeling-based analysis for the incidence of lightning on the 33 kV transmission line system is observed in this regard, and a Metal-Oxide surge arrestor-based lightning fault clearance safety scheme is also suggested and discussed.


Sign in / Sign up

Export Citation Format

Share Document