scholarly journals An integrated, multiparametric flow cytometry chip using “microfluidic drifting” based three-dimensional hydrodynamic focusing

2012 ◽  
Vol 6 (2) ◽  
pp. 024113 ◽  
Author(s):  
Xiaole Mao ◽  
Ahmad Ahsan Nawaz ◽  
Sz-Chin Steven Lin ◽  
Michael Ian Lapsley ◽  
Yanhui Zhao ◽  
...  
2020 ◽  
Vol 14 (6) ◽  
pp. 064110
Author(s):  
Yogesh M. Patel ◽  
Sanidhya Jain ◽  
Abhishek Kumar Singh ◽  
Kedar Khare ◽  
Sarita Ahlawat ◽  
...  

2021 ◽  
Vol 25 (3) ◽  
Author(s):  
Xiaofei Yuan ◽  
Andrew Glidle ◽  
Hitoshi Furusho ◽  
Huabing Yin

AbstractOptical-based microfluidic cell sorting has become increasingly attractive for applications in life and environmental sciences due to its ability of sophisticated cell handling in flow. The majority of these microfluidic cell sorting devices employ two-dimensional fluid flow control strategies, which lack the ability to manipulate the position of cells arbitrarily for precise optical detection, therefore resulting in reduced sorting accuracy and purity. Although three-dimensional (3D) hydrodynamic devices have better flow-focusing characteristics, most lack the flexibility to arbitrarily position the sample flow in each direction. Thus, there have been very few studies using 3D hydrodynamic flow focusing for sorting. Herein, we designed a 3D hydrodynamic focusing sorting platform based on independent sheath flow-focusing and pressure-actuated switching. This design offers many advantages in terms of reliable acquisition of weak Raman signals due to the ability to precisely control the speed and position of samples in 3D. With a proof-of-concept demonstration, we show this 3D hydrodynamic focusing-based sorting device has the potential to reach a high degree of accuracy for Raman activated sorting.


2016 ◽  
Vol 82 (3) ◽  
pp. 440
Author(s):  
Michael Cubbage ◽  
Kenneth McClain ◽  
Michele Redell ◽  
Judith Margolin ◽  
Reshma Kulkarni ◽  
...  

1999 ◽  
Author(s):  
Yow-Min D. Tsao ◽  
Steve R. Gonda

Abstract The Hydrodynamic Focusing Bioreactor (HDFB) developed by NASA at the Johnson Space Center provides a unique hydrofocusing capability that simultaneously enables a low-shear culture environment and a unique hydrofocusing-based “herding” of suspended cells, cell aggregates, and air bubbles. The HDFB is a rotating dome-shaped cell culture vessel with a centrally located sampling port and an internal rotating viscous spinner attached to a rotating base. The vessel and viscous spinner can rotate at different speeds and in either the same or different directions. Adjusting the differential rotation rate between the vessel and spinner results in a controllable hydrodynamic focusing force. The resultant hydrodynamic force suspends the cells in a low-shear fluid environment that supports the formation of delicate three-dimensional tissue assemblies. Both suspension and anchorage-dependent cells have been successfully cultured.


Micromachines ◽  
2020 ◽  
Vol 11 (4) ◽  
pp. 349 ◽  
Author(s):  
Erik S. Hamilton ◽  
Vahid Ganjalizadeh ◽  
Joel G. Wright ◽  
Holger Schmidt ◽  
Aaron R. Hawkins

Optofluidic devices are capable of detecting single molecules, but greater sensitivity and specificity is desired through hydrodynamic focusing (HDF). Three-dimensional (3D) hydrodynamic focusing was implemented in 10-μm scale microchannel cross-sections made with a single sacrificial layer. HDF is achieved using buffer fluid to sheath the sample fluid, requiring four fluid ports to operate by pressure driven flow. A low-pressure chamber, or pit, formed by etching into a substrate, enables volumetric flow ratio-induced focusing at a low flow velocity. The single layer design simplifies surface micromachining and improves device yield by 1.56 times over previous work. The focusing design was integrated with optical waveguides and used in order to analyze fluorescent signals from beads in fluid flow. The implementation of the focusing scheme was found to narrow the distribution of bead velocity and fluorescent signal, giving rise to 33% more consistent signal. Reservoir effects were observed at low operational vacuum pressures and a balance between optofluidic signal variance and intensity was achieved. The implementation of the design in optofluidic sensors will enable higher detection sensitivity and sample specificity.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 5083-5083
Author(s):  
Raffaele Palmieri ◽  
Luca Maurillo ◽  
Alfonso Piciocchi ◽  
Maria Ilaria Del Principe ◽  
Valentina Arena ◽  
...  

Background: Mutations of the gene encoding Fms Related Tyrosine Kinase 3 (FLT3), at the juxta-membrane level (ITD), represent the most common lesions found in Acute Myeloid Leukemia (AML), identifying a subgroup of patients (pts) with unfavorable prognosis. FLT3-ITD mutations are considered an unreliable tool for measurable residual disease (MRD) monitoring, due to their intraclonal heterogeneity and instability during the course of disease. Instead, multiparametric flow cytometry (MFC) may represent an alternative to monitor MRD in this molecular subset. In fact, through the recognition and monitoring of leukemia associated immunophenotypes, MFC is applicable to > 90% of AML patients with a sensitivity of 10-4. Aims: The aim of our study was to investigate the reliability of MFC in MRD assessment of 72 FLT3-ITD positive pts whose treatment allocation was prospectively decided according to the genetic/cytogenetic profile at diagnosis and post consolidation MRD. FLT3-ITD pts were to receive, after induction and consolidation, allogeneic stem cell transplant (ASCT), whatever the source of stem cells. In this subgroup analysis, we investigated if FLT3-ITD mutated pts have a different propensity to achieve high quality (e.g. MRD negative) complete remission as compared to FLT3 wildtype ones. Furthermore, we seek for a correlation between different levels of MRD and overall (OS) and disease-free survival (DFS). Methods: We included in the analysis 72 pts with de novo AML carrying FLT3-ITD mutations whose MRD assessment at the post-consolidation timepoint was available. Pts were defined as MRD-negative, when obtaining a residual leukemic cells count below the threshold of 3.5x10-4 (0.035%). MRD positive pts (with MRD ≥ 3.5x10-4 RLC) were stratified into 3 classes according to the levels of MRD (0.035%-0.1%; >0.1%-1%; >1%). We compared the MRD status and clinical outcome with a matched group of FLT3 wildtype AML (n = 203) treated in the same protocol. Results: Overall median age was 49 (range 18-60.9). The 2 cohorts were balanced in terms of age and sex distribution. In the FLT3-ITD group, 80/126 (64%) cases carried a concomitant NPM1 mutation vs 107/374 (28.6%) of FLT3 wildtype ones (p <0.001). Furthermore, FLT3 mutated pts had a median WBC count of 35x109/L vs 9.5x109/L of those FLT3 wildtype (p < 0.001). MRD determination after consolidation cycle was available in 72/126 FLT3-ITD pts (57%) and in 203/374 FLT3 wildtypeones (54.3%), respectively. After having received induction and consolidation course, 47/72 FLT3-ITD pts (65,2%) were submitted to allogenic stem cells transplantation (ASCT). At the post-consolidation time-point, MRD negativity rate was significantly lower in FTL3-ITD pts (27/72, 37.5%) as compared to those FLT3 wildtype (94/203, 46.3%). Furthermore, 38/72 (52.8%) and 10/72 (13.9%) FLT3-ITD pts had a level of MRD > 0.1% and > 1%, respectively as compared to 65/203 (33.0%) and 15/203 (7.4%) of FLT3 wildtypeones, respectively (p=0.017). When considering the different MRD stratification levels of FLT3-ITD pts, OS probability at 24 months was 57.2% (27 pts), 71.4% (7 pts), 53.6% (28 pts) and 20% (10 pts), for the MRD categories <0.035%, 0.035%-0.1%, >0.1%-1%, >1%, respectively (p=0.028). DFS probability at 24 months was 53.8% (27 pts), 71.4% (7 pts), 34.9% (27 pts) and 20% (10 pts), for the MRD categories <0.035%, 0.035%-0.1%, >0.1%-1%, >1%, respectively (p=0.038). Summary/Conclusion: We demonstrated that MRD determination by MFC is a reliable tool to assess remission quality and prognosis in FLT-ITD positive patients. This subpopulation shows a lower propensity to obtain a MRD negative CR, with the majority of pts maintaining an amount of MRD > 0.1% after standard treatment. Even though most of these pts were addressed to ASCT, post-consolidation MRD maintained its negative impact on OS and DFS, particularly for those pts with MRD >1%. In the attempt to improve the quality of response, prevent leukemia recurrence and pursue a durable remission, delivery of FLT3 inhibitors as a maintenance after transplant may represent a promising option. Disclosures Venditti: Novartis: Consultancy, Membership on an entity's Board of Directors or advisory committees; Abbvie: Consultancy; Astellas: Membership on an entity's Board of Directors or advisory committees; Pfizer: Consultancy, Membership on an entity's Board of Directors or advisory committees; Daiichi-Sankyo: Consultancy, Membership on an entity's Board of Directors or advisory committees. Buccisano:Janssen: Membership on an entity's Board of Directors or advisory committees; Astellas: Membership on an entity's Board of Directors or advisory committees; Novartis: Consultancy, Membership on an entity's Board of Directors or advisory committees, Speakers Bureau.


Sign in / Sign up

Export Citation Format

Share Document