Determination of perpendicular magnetic anisotropy in ultrathin ferromagnetic films by extraordinary Hall voltage measurement

2009 ◽  
Vol 80 (11) ◽  
pp. 113904 ◽  
Author(s):  
Kyoung-Woong Moon ◽  
Jae-Chul Lee ◽  
Sug-Bong Choe ◽  
Kyung-Ho Shin
2013 ◽  
Vol 88 (2) ◽  
Author(s):  
H. J. Qin ◽  
Kh. Zakeri ◽  
A. Ernst ◽  
T.-H. Chuang ◽  
Y.-J. Chen ◽  
...  

2019 ◽  
Vol 89 (1) ◽  
pp. 72
Author(s):  
В.В. Демидов ◽  
А.Е. Мефёд

AbstractPossibilities of magnetic pseudoresonance (a non-resonance peak of magnetic susceptibility) were studied and compared with the ferromagnetic resonance (FMR) in measuring the parameters of thin ferromagnetic films with in-plane uniaxial magnetic anisotropy. The measurements were conducted with two characteristic samples of ferromagnetic films showing this effect. A Q -meter operating at a frequency near 300 MHz (for pseudoresonance) and a standard X -band magnetic resonance spectrometer (for FMR) were used. The Q -meter working at 300 MHz was shown to detect reliably the magnetic pseudoresonance in both epitaxial and polycrystalline films. It was found that the accuracy of determination of the magnetic anisotropy field and orientation of the easy magnetization axis provided by the pseudoresonance method is as good as with FMR, and in some cases the pseudoresonance method gives additional information.


2020 ◽  
Vol 3 (2) ◽  
pp. 024001 ◽  
Author(s):  
Louis-Charles Garnier ◽  
Massimiliano Marangolo ◽  
Mahmoud Eddrief ◽  
Diego Bisero ◽  
Samuele Fin ◽  
...  

2018 ◽  
Vol 57 (5) ◽  
pp. 050308 ◽  
Author(s):  
Tomoe Nishimura ◽  
Duck-Ho Kim ◽  
Takaya Okuno ◽  
Yuushou Hirata ◽  
Yasuhiro Futakawa ◽  
...  

Author(s):  
A.E.M. De Veirman ◽  
F.J.G. Hakkens ◽  
W.M.J. Coene ◽  
F.J.A. den Broeder

There is currently great interest in magnetic multilayer (ML) thin films (see e.g.), because they display some interesting magnetic properties. Co/Pd and Co/Au ML systems exhibit perpendicular magnetic anisotropy below certain Co layer thicknesses, which makes them candidates for applications in the field of magneto-optical recording. It has been found that the magnetic anisotropy of a particular system strongly depends on the preparation method (vapour deposition, sputtering, ion beam sputtering) as well as on the substrate, underlayer and deposition temperature. In order to get a better understanding of the correlation between microstructure and properties a thorough cross-sectional transmission electron microscopy (XTEM) study of vapour deposited Co/Pd and Co/Au (111) MLs was undertaken (for more detailed results see ref.).The Co/Pd films (with fixed Pd thickness of 2.2 nm) were deposited on mica substrates at substrate temperatures Ts of 20°C and 200°C, after prior deposition of a 100 nm Pd underlayer at 450°C.


2002 ◽  
Vol 81 (21) ◽  
pp. 4017-4019 ◽  
Author(s):  
T. G. Kim ◽  
Y. H. Shin ◽  
J. H. Song ◽  
M. C. Sung ◽  
I. S. Kim ◽  
...  

2021 ◽  
pp. 1-1
Author(s):  
I. Benguettat-El Mokhtari ◽  
Y. Roussigne ◽  
S. M. Cherif ◽  
S. Auffret ◽  
C. Baraduc ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document