Abrupt Change in X-ray and Ion Emission of the PALS Laser Plasma at Laser Intensity of ∼10[sup 15] W∕cm[sup 2]

2008 ◽  
Author(s):  
L. Ryć ◽  
J. Krása ◽  
L. Láska ◽  
P. Parys ◽  
K. Rohlena ◽  
...  
2008 ◽  
Vol 26 (3) ◽  
pp. 473-478 ◽  
Author(s):  
S. Chaurasia ◽  
D.S. Munda ◽  
P. Ayyub ◽  
N. Kulkarni ◽  
N.K. Gupta ◽  
...  

AbstractIn this paper, we present the results of studies on ion emission characteristics of a laser plasma produced from a copper nano-particle layer of 1–3 µm thickness coated over polished surface of a solid copper target. Laser intensity of 1013–1014 W/cm2 was produced on the targets by a 2 J Nd:glass laser having a variable pulse duration of 300–800 ps. Nano-particle size was in the range of 15–25 nm. Ion emission from the nano-particle plasma was compared with plasma generated from a polished copper target. Ion emission from the nano-structured target was observed to depend on the polarization of the incident laser beam. This effect was stronger for a shorter laser pulse. X-ray emission was measured in the soft and hard X-ray region (0.7 to 8 keV) using various X-ray filters. A nano-particle coated target is found to yield a larger flux as well as velocity of ions as compared to polished target when the laser polarization is parallel to the plane containing target normal and detector axis. However, no X-ray enhancement has been observed in the wavelength range 1.5 to 20 Å.


2001 ◽  
Vol 72 (3) ◽  
pp. 385-387 ◽  
Author(s):  
H. Daido ◽  
S. Yamagami ◽  
M. Suzuki ◽  
H. Azuma ◽  
I.W. Choi ◽  
...  
Keyword(s):  
X Ray ◽  

1992 ◽  
Vol 10 (4) ◽  
pp. 777-786 ◽  
Author(s):  
Xiaofang Wang ◽  
Zhizhan Xu ◽  
Shisheng Chen ◽  
Aidi Qian ◽  
Yueling Li ◽  
...  

The effect of laser intensity distribution along the line focus on the uniformity of the line-shaped plasmas produced is investigated with time-integrated and time-resolved soft X-ray and optical diagnostics. Evident plasma condition nonuniformities along the line focus resulting from nonuniform laser intensity distributions have been observed with a conventional simple line-focusing technique. With a new line-focusing technique producing a uniform laser illumination, a uniform, line-shaped plasma can be obtained. It is also found that nonuniformities under uniform laser illumination occur mostly during laser heating. The line-shaped uniform laser plasma can be used as a large, uniform X-ray source besides its importance in X-ray laser demonstration and amplification. As an application of such line-shaped plasmas as X-ray sources, the no-overcoat 5F X-ray film is calibrated for the first time by a new method in the soft X-ray range from 10–80 A.


2007 ◽  
Vol 102 (6) ◽  
pp. 063303 ◽  
Author(s):  
S. V. Gasilov ◽  
A. Ya. Faenov ◽  
T. A. Pikuz ◽  
P. Villoresi ◽  
L. Poletto ◽  
...  

2009 ◽  
Vol 129 (4) ◽  
pp. 595-600
Author(s):  
Tetsuya Makimura ◽  
Takashige Fujimori ◽  
Shuichi Torii ◽  
Hiroyuki Niino ◽  
Kouichi Murakami

2001 ◽  
Vol 92 (6) ◽  
pp. 998-1003 ◽  
Author(s):  
A. A. Erokhin ◽  
A. S. Kishinets ◽  
Yu. V. Korobkin ◽  
I. V. Romanov ◽  
V. M. Romanova ◽  
...  
Keyword(s):  

2001 ◽  
Author(s):  
Takayasu Mochizuki ◽  
Atsushi Shimoura ◽  
Sho Amano ◽  
Shuji Miyamoto

2015 ◽  
Vol 71 ◽  
pp. 146-149 ◽  
Author(s):  
A.V. Balovnev ◽  
E.D. Vovchenko ◽  
I.G. Grigoryeva ◽  
E.I. Dodulad ◽  
A.S. Savelov ◽  
...  

1991 ◽  
Vol 9 (2) ◽  
pp. 579-591 ◽  
Author(s):  
L. Pína ◽  
H. Fiedorowicz ◽  
M. O. Koshevoi ◽  
A. A. Rupasov ◽  
B. Rus ◽  
...  

A program is under way to develop methods and instrumentation based on charge-coupled device (CCD) sensors for hot plasma diagnostics. We have developed a new X-ray spectrometer in which a freestanding X-ray transmission grating is coupled to a CCD linear array detector with electronic digitized readout replacing film and its wet processing. This instrument measures time-integrated pulsed X-ray spectra with moderate spectral resolution (δλ ≤ 0.6 nm) over a broad spectral range (0.3–2 keV) with high sensitivity, linearity, and large dynamic range. The performance of the device was tested using laser plasma as the X-ray source.


1997 ◽  
Author(s):  
Zhongxing Shao ◽  
Zhanshan Wang ◽  
Fengming Xu ◽  
Junxia Lu ◽  
Xingdan Chen

Sign in / Sign up

Export Citation Format

Share Document