scholarly journals Beryllium window and acoustic delay line design for x‐ray lithography beam lines at the University of Wisconsin Center for X‐ray Lithography

1992 ◽  
Vol 63 (1) ◽  
pp. 749-752 ◽  
Author(s):  
E. L. Brodsky ◽  
W. Hamilton ◽  
G. Wells ◽  
F. Cerrina ◽  
M. Corradini
2021 ◽  
Author(s):  
Emily J. King ◽  
Natalie N. Viscariello ◽  
Larry A. DeWerd

This work seeks to develop standard X-ray beams that are matched to radiobiology X-ray irradiators. The calibration of detectors used for dose determination of these irradiators is performed with a set of standard X rays that are more heavily filtered and/or lower energy, which leads to a higher uncertainty in the dose measurement. Models of the XRad320, SARRP, and the X-ray tube at the University of Wisconsin Medical Radiation Research Center (UWMRRC) were created using the BEAMnrc user code of the EGSnrc Monte Carlo code system. These models were validated against measurements, and the resultant modeled spectra were used to determine the amount of added filtration needed to match the X-ray beams at the UWMRRC to those of the XRad320 and SARRP. The depth profiles and half-value layer (HVL) simulations performed using BEAMnrc agreed to measurements within 3% and 3.6%, respectively. A primary measurement device, a free-air chamber, was developed to measure air kerma in the medium energy range of X rays. The resultant spectra of the matched beams had HVL's that matched the HVL's of the radiobiology irradiators well within the 3% criteria recommended by the International Atomic Energy Agency (IAEA) and the average energies agreed within 2.4%. In conclusion, three standard X-ray beams were developed at the UWMRRC with spectra that more closely match the spectra of the XRad320 and SARRP radiobiology irradiators, which will aid in a more accurate dose determination during calibration of these irradiators.


1994 ◽  
Vol 71 (4) ◽  
pp. 1528-1545 ◽  
Author(s):  
D. J. Ostry ◽  
K. G. Munhall

1. The kinematics of sagittal-plane jaw motion were assessed in mastication and speech. The movement paths were described in joint coordinates, in terms of the component rotations and translations. The analysis focused on the relationship between rotation and horizontal translation. Evidence was presented that these can be separately controlled. 2. In speech, jaw movements were studied during consonant-vowel utterances produced at different rates and volumes. In mastication, bolus placement, compliance, and size as well as chewing rate were manipulated. Jaw movements were recorded using the University of Wisconsin X-ray microbeam system. Jaw rotation and translation were calculated on the basis of the motion of X-ray tracking pellets on the jaw. 3. The average magnitudes of jaw rotation and translation were greater in mastication than in speech. In addition, in speech, it was shown that the average rotation magnitude may vary independent of the horizontal translation magnitude. In mastication, the average magnitude of vertical jaw translation was not dependent on the magnitudes of jaw rotation or horizontal jaw translation. 4. The magnitude of rotation and horizontal jaw translation tended to be correlated when examined on a trial by trial basis. Some subjects also showed a correlation between jaw rotation and vertical jaw translation. However, the proportion of variance accounted for was greater for all subjects in the case of rotation and horizontal translation. 5. Joint space paths in both mastication and speech were found to be straight. The pattern was observed at normal and fast rates of speech and mastication and for loud speech as well. Straight line paths were also observed when subjects produced utterances that had both the syllabic structure and the intonation pattern of speech. The findings suggest that control may be organized in terms of an equilibrium jaw orientation and an equilibrium jaw position. 6. Departures from linearity were also observed. These were typically associated with differences during jaw closing in the end time of rotation and translation. Start time differences were not observed in jaw closing and the movement paths were typically linear within this region.


2000 ◽  
Vol 122 (03) ◽  
pp. 64-67 ◽  
Author(s):  
Leo O’Connor ◽  
Harry Hutchinson

This article reviews to enrich the variety of microelectromechanical systems (MEMS) to open new applications and markets. Established manufacturing methods for most MEMS were developed for electronics, and so the microcromachines turned out that way generally look like chips. The selection of materials is usually limited, and height, measured in microns, often remains in the single digits and rarely exceeds 20. Work at the University of Wisconsin in Madison is proceeding with a process that uses deep X-ray lithography. The technique is derived from an established micromanufacturing process known as LIGA, an acronym derived from the German terms for lithography, electroforming, and molding. LIGA, which has been around for a while, produces relatively tall micromachines by a method that radiates X-ray-sensitive materials to create molds. EFAB is being developed by USC’s Information Sciences Institute with funding from the Defense Advanced Research Projects Agency. To support commercialization of the process, the Institute has established the EFAB Consortium, which intends to give interested partners the option of acquiring prototype micro devices fabricated from their own 3D CAD designs.


Author(s):  
Hans Ris

The High Voltage Electron Microscope Laboratory at the University of Wisconsin has been in operation a little over one year. I would like to give a progress report about our experience with this new technique. The achievement of good resolution with thick specimens has been mainly exploited so far. A cold stage which will allow us to look at frozen specimens and a hydration stage are now being installed in our microscope. This will soon make it possible to study undehydrated specimens, a particularly exciting application of the high voltage microscope.Some of the problems studied at the Madison facility are: Structure of kinetoplast and flagella in trypanosomes (J. Paulin, U. of Georgia); growth cones of nerve fibers (R. Hannah, U. of Georgia Medical School); spiny dendrites in cerebellum of mouse (Scott and Guillery, Anatomy, U. of Wis.); spindle of baker's yeast (Joan Peterson, Madison) spindle of Haemanthus (A. Bajer, U. of Oregon, Eugene) chromosome structure (Hans Ris, U. of Wisconsin, Madison). Dr. Paulin and Dr. Hanna are reporting their work separately at this meeting and I shall therefore not discuss it here.


Author(s):  
S. Edith Taylor ◽  
Patrick Echlin ◽  
May McKoon ◽  
Thomas L. Hayes

Low temperature x-ray microanalysis (LTXM) of solid biological materials has been documented for Lemna minor L. root tips. This discussion will be limited to a demonstration of LTXM for measuring relative elemental distributions of P,S,Cl and K species within whole cells of tobacco leaves.Mature Wisconsin-38 tobacco was grown in the greenhouse at the University of California, Berkeley and picked daily from the mid-stalk position (leaf #9). The tissue was excised from the right of the mid rib and rapidly frozen in liquid nitrogen slush. It was then placed into an Amray biochamber and maintained at 103K. Fracture faces of the tissue were prepared and carbon-coated in the biochamber. The prepared sample was transferred from the biochamber to the Amray 1000A SEM equipped with a cold stage to maintain low temperatures at 103K. Analyses were performed using a tungsten source with accelerating voltages of 17.5 to 20 KV and beam currents from 1-2nA.


Author(s):  
K.K. Soni ◽  
D.B. Williams ◽  
J.M. Chabala ◽  
R. Levi-Setti ◽  
D.E. Newbury

In contrast to the inability of x-ray microanalysis to detect Li, secondary ion mass spectrometry (SIMS) generates a very strong Li+ signal. The latter’s potential was recently exploited by Williams et al. in the study of binary Al-Li alloys. The present study of Al-Li-Cu was done using the high resolution scanning ion microprobe (SIM) at the University of Chicago (UC). The UC SIM employs a 40 keV, ∼70 nm diameter Ga+ probe extracted from a liquid Ga source, which is scanned over areas smaller than 160×160 μm2 using a 512×512 raster. During this experiment, the sample was held at 2 × 10-8 torr.In the Al-Li-Cu system, two phases of major importance are T1 and T2, with nominal compositions of Al2LiCu and Al6Li3Cu respectively. In commercial alloys, T1 develops a plate-like structure with a thickness <∼2 nm and is therefore inaccessible to conventional microanalytical techniques. T2 is the equilibrium phase with apparent icosahedral symmetry and its presence is undesirable in industrial alloys.


Author(s):  
Patricia N. Hackney

Ustilago hordei and Ustilago violacea are yeast-like basidiomycete pathogens ofHordeum vulgare and Silene alba respectively. The mating type system in both species of Ustilago is bipolar, with alleles, A,a, (U.hordei) and a1, a2 (U.violacea) at a single locus. Haploid sporidia maintain the asexual phase by budding, while the sexual phase is initiated by conjugation tube formation between the mating types during budding and conjugation.For observation of budding, sporidia were prepared by culturing the four types on YEG (yeast extract glucose) broth for 24 hours. After centrifugation at 5000g cells were either left unmated or mated in a1/a2,A/a combinations. The sporidia were then mixed 1:1 with 4% agar and the resulting 1mm cubes fixed in 8% gluteraldehyde and post fixed in osmium tetroxide. After dehydration and embedding cubes were thin sectioned with a LKB ultratome and photographed in a Zeiss 9s transmission electron microscope or in an AE1 electron microscope of MK11 1MEV at the High Voltage Electron Microscopy Center of the University of Wisconsin-Madison.


Sign in / Sign up

Export Citation Format

Share Document