High precision temperature‐ and energy‐dependent refractive index of GaAs determined from excitation of optical waveguide eigenmodes

1990 ◽  
Vol 57 (13) ◽  
pp. 1328-1330 ◽  
Author(s):  
S. R. Kisting ◽  
P. W. Bohn ◽  
E. Andideh ◽  
I. Adesida ◽  
B. T. Cunningham ◽  
...  
2007 ◽  
Vol 21 (30) ◽  
pp. 5075-5089 ◽  
Author(s):  
HALA M. KHALIL ◽  
MOHAMMED M. SHABAT ◽  
SOFYAN A. TAYA ◽  
MAZEN M. ABADLA

In this work, we present an extensive theoretical analysis of nonlinear optical waveguide sensor. The waveguide under consideration consists of a thin dielectrica film surrounded by a self-focused nonlinear cladding and a linear substrate. The nonlinearity of the cladding is considered to be of Kerr-type. Both cases, when the effective refractive index is greater and when it is smaller than the index of the guiding layer, are discussed. The sensitivity of the effective refractive index to any change in the cladding index in evanescent optical waveguide sensor is derived for TM modes. Closed form analytical expressions and normalized charts are given to provide the conditions required for the sensor to exhibit its maximum sensitivity. The results are compared with those of the well-known linear evanescent waveguide sensors.


2010 ◽  
Vol 03 (02) ◽  
pp. 91-102 ◽  
Author(s):  
TING LI ◽  
HUI GONG ◽  
QINGMING LUO

The Monte Carlo code MCML (Monte Carlo modeling of light transport in multi-layered tissue) has been the gold standard for simulations of light transport in multi-layer tissue, but it is ineffective in the presence of three-dimensional (3D) heterogeneity. New techniques have been attempted to resolve this problem, such as MCLS, which is derived from MCML, and tMCimg, which draws upon image datasets. Nevertheless, these approaches are insufficient because of their low precision or simplistic modeling. We report on the development of a novel model for photon migration in voxelized media (MCVM) with 3D heterogeneity. Voxel crossing detection and refractive-index-unmatched boundaries were considered to improve the precision and eliminate dependence on refractive-index-matched tissue. Using a semi-infinite homogeneous medium, steady-state and time-resolved simulations of MCVM agreed well with MCML, with high precision (~100%) for the total diffuse reflectance and total fractional absorption compared to those of tMCimg (< 70%). Based on a refractive-index-matched heterogeneous skin model, the results of MCVM were found to coincide with those of MCLS. Finally, MCVM was applied to a two-layered sphere with multi-inclusions, which is an example of a 3D heterogeneous media with refractive-index-unmatched boundaries. MCVM provided a reliable model for simulation of photon migration in voxelized 3D heterogeneous media, and it was developed to be a flexible and simple software tool that delivers high-precision results.


2010 ◽  
Vol 428-429 ◽  
pp. 487-492
Author(s):  
Xi Yin ◽  
Xiao Jun Wang ◽  
Yong Que Xie

This thesis introduces a low cost and high precision temperature cycle measurement system with adoption of PT100 as temperature sensor, with single chip computer as the core. The method of sub-three-wire connection is proposed for engineering practice, then, can eliminate the effects of lead wire resistance and simplify the external cable connection. We discuss and research circuit component selection, circuit design, improving system reliability, and a software method of piecewise linearization process is adopted, thus we ensure exact and reliable measure and the system characteristic of low cost and high precision.


Sign in / Sign up

Export Citation Format

Share Document