Voltage waveform distortion in synchronous generators with rectifier loading

1980 ◽  
Vol 127 (1) ◽  
pp. 13 ◽  
Author(s):  
W.J. Bonwick
2013 ◽  
Vol 392 ◽  
pp. 409-412
Author(s):  
Xian Bin Dai ◽  
Xiao Hua Yuan ◽  
Wei Du

This paper introduces the working principle of the research of simulation in the main circuit of Static Var Generator based on Cascade H-Bride and takes the three-phase Static Var Generator based on cascade H-Bride with rated capacity 10kVar,rated voltage 380V for example to proceed the MATLAB simulation. The research shows that the more amount of cascade H-Bride, the more number of output voltage levels in the main circuit of Static Var Generator, the smaller value of voltage waveform distortion factor, and the less harmonic content be inject in electric network, which improves power index.


2011 ◽  
Vol 467-469 ◽  
pp. 1438-1443
Author(s):  
Hu Huang ◽  
Jia Fen He

Voltage waveform distortion of Aeronautical Static Inverter (ASI) has a solution, which is the repetitive control technology. In this paper, have established the model of repetitive control system; have stated its principles and method of parameter design; have proved the stability of repetitive control system; have verified the validity of it in MATLAB software; finally have established its C language procedure.


1993 ◽  
Vol 40 (3) ◽  
pp. 373-383 ◽  
Author(s):  
J.-C. Montano ◽  
B.J. Gutierrez ◽  
O.A. Lopez ◽  
I.M. Castilla

1993 ◽  
Vol 113 (1) ◽  
pp. 70-79 ◽  
Author(s):  
Kazumasa Ide ◽  
Miyoshi Takahashi ◽  
Motoya Ito ◽  
Eiji Tsuji ◽  
Yasuhiro Yasaka ◽  
...  

2015 ◽  
Vol 1092-1093 ◽  
pp. 296-299
Author(s):  
De Wei Zhang ◽  
Zhen Nan Fan

To reduce the tubular hydro-generator no-load voltage waveform distortion,some different design schemes of stator slot skewing degree in a 36MW fractional slot tubular hydro-generator (q=11/2 ) are calculated and compared. Then, the relation of the no-load voltage waveform harmonic distortion factor (HDF) and stator slot skewing degree are revealed. The research provides the important reference informations for the optimization of no-load voltage waveform , and it is helpful for improving the industral design and manufacture standard of tubular hydro-generator.


1991 ◽  
Vol 111 (8) ◽  
pp. 661-668 ◽  
Author(s):  
Kazumasa Ide ◽  
Miyoshi Takahashi ◽  
Motoya Ito ◽  
Eiji Tsuji ◽  
Yasuhiro Yasaka ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 777
Author(s):  
Marek Wasowski ◽  
Tomasz Sikorski ◽  
Grzegorz Wisniewski ◽  
Pawel Kostyla ◽  
Jaroslaw Szymanda ◽  
...  

Knowledge of the conducted emissions in the frequency range 2–150 kHz contains some gaps related to the impact of the harmonics in the supply voltage on the nature of these emissions. It can be noticed that the conducted emissions from non-sinusoidal power supplies have not been studied sufficiently, and that the impact of this distortion may be greater than the generally known results of emission tests carried out under standardized test conditions. This paper is aimed at investigating experimental cases of the influence of supply voltage waveform distortion on non-intentional emission in the range 2–150 kHz and the efficiency of power line communication based on selected PRIME (PoweRline Intelligent Metering Evolution) power line communication (PLC) technology. A series of experimental laboratory studies were investigated, representing the operation of the investigated PLC system with different types of end-user equipment (LED—Light Emitting Diode, CFL—Compact Fluorescent Lamp, induction motor with frequency converter) working under a distorted supply voltage condition obtained by the programmable power supply for different scenarios of the admissible harmonics contribution in the range 0–2 kHz. The scenarios included limits defined in standards EN 50160 and IEC 61000-4-13. The researchers used spectral analysis with a notation to emission limits, compatibility levels, and mains signalling, as well as statistics of the PLC communication. The obtained results provide important conclusions, which may be applied both in the development of the design of the appliances in question and the higher frequency emission testing methods.


Sign in / Sign up

Export Citation Format

Share Document