Consistency of Electroacoustic Characteristics Across Components of FM Systems

1991 ◽  
Vol 34 (3) ◽  
pp. 628-635 ◽  
Author(s):  
Linda M. Thibodeau ◽  
Kathryn A. Saucedo

In the absence of national or international electroacoustic standards for the evaluation of Frequency Modulated (FM) amplification systems, it becomes important to know the variability one may expect across similar models. Evaluation of thirty FM systems of the same model obtained from three different educational sites was performed to determine the variability that may occur as a result of the receiver, lapel microphone, or neckloop. There was a range as great as 20 dB in high frequency average saturation sound pressure level and equivalent input noise across receivers, lapel microphones, and neckloops. These results highlight the need for regular electroacoustic monitoring of not only the FM transmitter and receiver, but also the individual components, such as the lapel microphone and the neckloop.

1990 ◽  
Vol 63 (3) ◽  
pp. 570-591 ◽  
Author(s):  
D. R. Irvine ◽  
G. Gago

1. Development of models of the manner in which interaural intensity differences (IIDs), the major binaural cue for the azimuthal location of high-frequency sounds, are coded by populations of neurons requires knowledge of the extent to which the IID sensitivity of individual neurons is invariant with changes in sound pressure level (SPL) and other stimulus parameters. To examine this tissue, recordings were obtained from a large sample (n = 458) of neurons with characteristic frequency (CF) greater than 3 kHz in the central nucleus of the inferior colliculus (ICC) of anesthetized cats. The sensitivity to IIDs and the effects of changes in SPL on this sensitivity were examined in neurons receiving excitatory contralateral input and inhibitory or mixed inhibitory/facilitatory ipsilateral input (EI neurons). 2. The form of an EI neuron's IID sensitivity and the effects of changes in SPL on that sensitivity were found to be determined in part by the characteristics of the neuron's rate-intensity function for monaural contralateral stimulation, and detailed rate-intensity functions were therefore obtained for 91 neurons. Many ICC neurons have nonmonotonic rate-intensity functions, the proportion so classified depending on the criterion of nonmonotonicity employed. 3. IID sensitivity functions for CF tonal stimuli were obtained at one or more intensities for 90 neurons, using a method of generating IIDs that kept the average binaural intensity (ABI) of the stimuli at the two ears constant. In the standard ABI range in which a function was obtained for each unit, the majority of EI neurons (72%) had monotonic (sigmoidal) or near-monotonic IID sensitivity functions. The remainder had nonmonotonic (peaked) IID sensitivity functions, which were attributable either to mixed inhibitory and facilitatory ipsilateral influences or to the fact that the effects of ipsilateral stimulation were superimposed on nonmonotonic effects of changes in intensity at the excitatory ear. 4. IID sensitivity was examined at two or more ABIs (3-5 in most cases) for 40 neurons classified as having monotonic or near-monotonic functions in the standard ABI range and for 7 neurons classified as nonmonotonic. For a small proportion of neurons with monotonic IID sensitivity functions, the form of the function was relatively invariant with changes in ABI. In those monotonic neurons in which the form of the IID sensitivity function varied with changes in ABI, the most common type of variation was that the position of the sloping portion of the function shifted systematically in the direction of larger IIDs favoring the ipsilateral ear as ABI increased.(ABSTRACT TRUNCATED AT 400 WORDS)


2011 ◽  
Vol 105-107 ◽  
pp. 74-79
Author(s):  
Zha Gen Ma ◽  
Xue Ying Xu ◽  
Guo Hua Han

As cars become quieter the sound quality of components becomes more critical in the customer perception of car quality. This requires a need of new evaluation method for the specification of component sounds. Considering that high frequency noise plays an important roll for internal noise, the noise signals in the range from 7000Hz to 8000Hz are specially emphasized. Then the acoustic evaluation parameters, such as Sound Pressure Level, Sharpness and Steadiness have been evaluated. Judged from experiences and measuring results, an abnormal noise comes from Generator, through the exchange of Generator, Sound Pressure Level and sharpness were greatly improved. At the same time, subjective evaluation also indicated that there was no complaint any more in passenger compartment. Low Sound Pressure Level, sharpness can lead to perceived high product quality.


2011 ◽  
Vol 243-249 ◽  
pp. 4447-4450 ◽  
Author(s):  
Yan Liu ◽  
Bing Yang ◽  
Xiao Pai Zhang ◽  
Zhi Fang Zhong ◽  
Hua Xin Dong ◽  
...  

Based on the comparative analysis on the low-noise road surface, noise reduction green belts, noise barriers and other noise reduction methods, the sound barrier is put forward as an important method for reducing the city road traffic noise. The noise reduction effects for different heights and different distances of the sound barrier are tested and analyzed through noise and vibration test and analysis system, the following conclusions can be drawn. At the same heights from the ground, the father the test points away from the noise barrier, the higher the sound pressure level will be; At the same distances from the sound barrier, the nearer the test points from the ground, the smaller the sound pressure level will be; All of the sound pressure level curves have basically the same variation trend and the main noise frequency band is from 160 to 1600Hz; In the high frequency range which is greater than 1600Hz, the sound pressure level decrease significantly, indicating that the sound barrier has better noise reduction effect for high frequency range. The results provide the basis for the design of the sound barriers.


2021 ◽  
Vol 69 (6) ◽  
pp. 518-529
Author(s):  
Changyong Jiang ◽  
Xiang Liu ◽  
Stephany Y. Xu ◽  
Shangyu Zhang

In this paper, the efficacy of porous ceiling treatment to reduce noise levels inside a typical tunnel is examined with a validated modal-based prediction method. It is found that, for a point source, the effect of increasing porous ceiling thickness on sound pressure level (SPL) attenuation along the tunnel is limited. A porous ceiling with thickness of 0.3 m is comparable with an infinite porous ceiling in middle and high frequency ranges. For a line source, the effect of ceiling thickness on SPL reduc- tion in this typical tunnel is limited. Sound pressure level reduction of 4 dBA is real- ized with 0.3 m porous ceiling, which is the same as infinite ceiling and only 1 dBA smaller than the theoretically optimized value. These results suggest that, in the event only ceiling treatment is considered, 0.3 m porous material is sufficient for noise re- duction in this typical tunnel.


Work ◽  
2021 ◽  
pp. 1-7
Author(s):  
Carina Moreno Dias Carneiro Muniz ◽  
Sergio Fernando Saraiva da Silva ◽  
Rachel Costa Façanha ◽  
Daniela Bassi-Dibai ◽  
Fabricio Brito Silva ◽  
...  

BACKGROUND: Musicians and dancers can be considered an at-risk population for developing noise-induced hearing loss. OBJECTIVES: To determine the audiological profile of members of a folklore-related music group and quantify noise exposure at their rehearsal venue. METHODS: This was a quantitative and descriptive study. The musicians and dancers were evaluated in two stages: an interview about their working life, followed by high frequency tonal audiometry. The sound pressure level in the group’s rehearsal venue was measured using a BEK 2270 Noise Analyzer. RESULTS: A total of 7.2% of the subjects had noise-induced hearing loss (NIHL) and 39% of the audiometric tests were notch type. During the interview 31.7% of the subjects mentioned discomfort from loud noise, although none of them used ear protection. The environmental assessment showed inadequate humidity and oscillating temperature. Twenty sound pressure level measurements were performed for Leq (equivalent sound pressure levels) and the results ranged from 88 dB (A) to 99 dB (A) with a mean of 97.05. CONCLUSIONS: Exposure to high levels of sound pressure has led to NIHL in some members of the group. Some of those with normal hearing also presented a notch configuration characteristic of NIHL. Tinnitus, indicating that a change in hearing has occurred, was the most frequent auditory symptom.


1990 ◽  
Vol 21 (1) ◽  
pp. 49-56 ◽  
Author(s):  
Linda M. Thibodeau

The purpose of this paper was to provide audiologists practical information regarding the use of direct-input hearing aids with FM systems. The degree to which the electroacoustic characteristics of direct-input hearing aids were preserved when used with two different personal FM systems was evaluated. Although there were limited changes in saturation sound pressure level and harmonic distortion, there was an increase in equivalent-input noise and full-on-gain. The frequency response curve of the aid + FM condition relative to the aid alone differed in the high frequencies for the two FM systems. Aids with equivalent gain values had varying amounts of gain when tested with the FM systems set at a constant volume control setting. This variability in the electroacoustic response of a given aid when coupled to a personal FM system suggests that one may not assume characteristics of the hearing aid are maintained when it is used with an FM system.


Author(s):  
Henrik Møller

Contours of equal annoyance were determined for pure tones in the frequency range 4 – 31.5 Hz. The curves show a narrowing of the dynamic range of the ear at low frequencies. The same pattern is seen for equal loudness curves, and the results support the theory that the annoyance of infrasound is closely related to the loudness sensation. Annoyance ratings of 1/3 octave noise did not deviate from ratings of pure tones with the same sound pressure level. Combinations of audio and infrasonic noise were in general given a rating close to or slightly above the rating of the most annoying of the individual noise conditions. For infrasound the proposed G1-weighting curve is shown to give values that correlate well with subjective annoyance rating. Values obtained with the G2-curve do not correlate as well. Low audio frequencies are not covered by the G-curves, and it is shown that these are insufficiently covered by the A-curve. Further research is needed in this area.


1982 ◽  
Vol 25 (4) ◽  
pp. 586-593 ◽  
Author(s):  
Lamar L. Young ◽  
Brenda Dudley ◽  
Melissa Byers Gunter

Two experiments were conducted concerning the relative intelligibility of spondaic words. In the first experiment, the 36 spondaic words typically used in clinical settings to determine the Speech-Recognition-Threshold (SRT) were presented to 20 subjects at levels ranging from to 10 to 28 dB SPL. The percentage of persons able to repeat each word was plotted as a function of decibel sound-pressure level to determine (a) the sound-pressure level necessary to yield a 50% response point for each word, and (b) the rate at which each word became intelligible, for example, the slope of the psychometric function. By these two criteria 15 words were found to be homogeneous. In the second experiment, SRTs were obtained on 24 subjects with the full list of 36 words and with the 15 spondaic words that were homogenous with respect to the sound-pressure level necessary for a 50% correct response level and the rate of intelligibility growth. The results demonstrate that the two groups of spondaic words yield equivalent SRTs. The data suggest that an SRT may be determined with 15 spondaic words, which is as valid and accurate as the SRT determined with the entire list of 36 words.


Sign in / Sign up

Export Citation Format

Share Document