Point of care whole blood microfluidics for detecting and managing thrombotic and bleeding risks.

Lab on a Chip ◽  
2021 ◽  
Author(s):  
Scott Diamond ◽  
Jason Rossi

Point-of-care diagnostics of platelet and coagulation function present demanding challenges. Current clinical diagnostics often use centrifuged plasmas or platelets and frozen plasma standards, recombinant protein standards, and even venoms. Almost...

The Analyst ◽  
2020 ◽  
Vol 145 (18) ◽  
pp. 6138-6147
Author(s):  
Xianbo Qiu ◽  
Huiqin Jiang ◽  
Xiaolei Zhang ◽  
Ke Li ◽  
Shengxiang Ge ◽  
...  

For point-of-care testing, a membrane-assisted, sedimentation-facilitated plasma separator with a multifunctional deformable chamber is developed to perform plasma separation from undiluted whole blood in a short time.


2021 ◽  
Author(s):  
Wan Zhou ◽  
Guanglei Fu [email protected] ◽  
Xiujun Li

<p>The volumetric bar-chart microfluidic chips (V-Chips) driven by chemical reaction-generated gas provide a promising platform for point-of-care (POC) visual biomarker quantitation. However, multiple limitations are encountered in conventional V-Chips, such as costly and complex chip fabrication, complicated assembly, and imprecise controllability of gas production. Herein, we introduced nanomaterial-mediated photothermal effects to V-Chips, and for the first time developed a new type of V-Chip, <u>p</u>hoto<u>t</u>hermal bar-chart microfluidic <u>c</u>hip (PT-Chip), for visual quantitative detection of biochemicals without any bulky and costly analytical instruments. Immunosensing signals were converted to visual readout signals via photothermal effects, the on-chip bar-chart movements, enabling quantitative biomarker detection on a low-cost polymer hybrid PT-Chip with on-chip scale rulers. Four different human serum samples containing prostate-specific antigen (PSA) as a model analyte were detected simultaneously using the PT-Chip, with the limit of detection of 2.1 ng/mL, meeting clinical diagnostic requirements. Although no conventional signal detectors were used, it achieved comparable detection sensitivity to absorbance measurements with a microplate reader. The PT-Chip was further validated by testing human whole blood without the color interference problem, demonstrating good analytical performance of our method even in complex matrixes and thus the potential to fill a gap in current clinical diagnostics that is incapable of testing whole blood. This new PT-Chip driven by nanomaterial-mediated photothermal effects opens a new horizon of microfluidic platforms for instrument-free diagnostics at the point of care.</p>


2021 ◽  
Author(s):  
Wan Zhou ◽  
Guanglei Fu [email protected] ◽  
Xiujun Li

<p>The volumetric bar-chart microfluidic chips (V-Chips) driven by chemical reaction-generated gas provide a promising platform for point-of-care (POC) visual biomarker quantitation. However, multiple limitations are encountered in conventional V-Chips, such as costly and complex chip fabrication, complicated assembly, and imprecise controllability of gas production. Herein, we introduced nanomaterial-mediated photothermal effects to V-Chips, and for the first time developed a new type of V-Chip, <u>p</u>hoto<u>t</u>hermal bar-chart microfluidic <u>c</u>hip (PT-Chip), for visual quantitative detection of biochemicals without any bulky and costly analytical instruments. Immunosensing signals were converted to visual readout signals via photothermal effects, the on-chip bar-chart movements, enabling quantitative biomarker detection on a low-cost polymer hybrid PT-Chip with on-chip scale rulers. Four different human serum samples containing prostate-specific antigen (PSA) as a model analyte were detected simultaneously using the PT-Chip, with the limit of detection of 2.1 ng/mL, meeting clinical diagnostic requirements. Although no conventional signal detectors were used, it achieved comparable detection sensitivity to absorbance measurements with a microplate reader. The PT-Chip was further validated by testing human whole blood without the color interference problem, demonstrating good analytical performance of our method even in complex matrixes and thus the potential to fill a gap in current clinical diagnostics that is incapable of testing whole blood. This new PT-Chip driven by nanomaterial-mediated photothermal effects opens a new horizon of microfluidic platforms for instrument-free diagnostics at the point of care.</p>


Nanoscale ◽  
2020 ◽  
Vol 12 (17) ◽  
pp. 9647-9652
Author(s):  
Ewelina Wajs ◽  
Girish Rughoobur ◽  
Keith Burling ◽  
Anne George ◽  
Andrew J. Flewitt ◽  
...  

TFBAR technology demonstrates a cost-effective means for point-of-care diagnostics and monitoring of PSA.


2017 ◽  
Vol 5 (1) ◽  
pp. 26
Author(s):  
Afnidar Afnidar ◽  
Bambang Kuswandi

Abstract This paper presents a low-cost and disposable paper based microfluidic analysis system for point-of-care diagnostics. Detection is achieved by using a colorimetric or visual indicator. Immobilized specific reagent or enzymes designed for the parameter under consideration act as capture molecules on the surface of the detection zone. The sensor is integrated into a microfluidic system made of paper (cellulose). An additional component of the analysis system is a capillary unit which is used to introduce the analyte to the detection zone. For this purpose well- defined, millimeter-sized channel, comprising hydrophobic polymer bounded onto hydrophilic paper was created. Then the detection zone was coated with a sensitive reagent layer as a sensor region. The paper based microfluidics also called lab on paper, has been fabricated using screen printing technology as the basis for low-cost, disposable, portable and technically simple fabrication for mass production. Microfluidics in paper make it feasible to run single, dual or even multiple clinical analyses on one strip of paper while still using only small volumes of a single sample. The capability of lab on paper for detection of importance clinical analyte protein in urine, saliva and blood samples has been demonstrate successfully. Lab on paper as a diagnostic system is small, disposable, and easy to use and requires no external equipment, reagents, or power sources. This kind of diagnostic system is attractive for use in developing countries, in the field, or as a low-cost alternative to more-advanced technologies already used in clinical diagnostics. Keywords: Lab-on-a-paper, Point-of-care, Visual detection, Clinical diagnostic, Disposable sensor


Blood ◽  
2018 ◽  
Vol 132 (Supplement 1) ◽  
pp. 3813-3813
Author(s):  
Joshua L Fenderson ◽  
Michael Adam Meledeo ◽  
Matthew J Rendo ◽  
Grantham Peltier ◽  
Colby McIntosh ◽  
...  

Abstract Background Cryoprecipitate (cryo) is a frozen plasma derivative consisting of fibrinogen, factor (F) XIII, FVIII and von Willebrand factor (vWF), and was originally intended to replace FVIII in hemophilia. Today, cryo is primarily used as fibrinogen replacement in acquired coagulopathy related to trauma, obstetric hemorrhage, and DIC. Due to the lability of FVIII, guidelines mandate that cryo be given within 6 hours of thawing. Fibrinogen is much more stable; however, and these time constraints may unnecessarily contribute to delayed product utilization and increased waste. Viscoelastic assays are increasingly used to assess coagulopathy and may be better indicators of global coagulation function than standard coagulation assays. Here we evaluated the performance of thawed, refrigerated cryoprecipitate over extended storage times. Methods Cryo (six donor pools, n=8) was purchased from South Texas Blood and Tissue, thawed on first day of testing, and stored in aliquots refrigerated at 4°C for up to 35 days. Assays were performed in 37°C rewarmed product at baseline post-thaw and at 4, 24, and 72h, and then weekly to 35 days. Assays for factor levels were conducted in cryo diluted 1:10 in PBS and using a hematology analyzer (Stago) for fibrinogen and FVIII or by ristocetin cofactor assay (RCo) for vWF (Siemens). Coagulation and thrombin generation of stored cryo was tested in ROTEM and Calibrated Automated Thrombogram (CAT) by mixing cryo with frozen aliquots of cryo-poor plasma. A massive transfusion protocol (MTP) was simulated by combining cryo with red cells, fresh frozen plasma, and fresh apheresis platelets (1:1:1:1 ratio); this simulation was tested for coagulation with ROTEM and for vWF-mediated fluorescent-labeled platelet adhesion to collagen in a microfluidics flow system (Bioflux). Results In simulated MTP, global coagulation function as measured by EXTEM and FIBTEM G-values from ROTEM were above normal reference ranges for whole blood for the entire 35d period (EXTEM smallest median G=13592 dyn/cm2, ref. range=4800-12250; FIBTEM smallest median G=2041, ref. range=495-1667). There was a slight decline in G value over storage duration, but it was not statistically significant (Fig 1). Lysis index at 30 min (LI30) in the EXTEM of simulated MTP did not statistically deviate over time (Fig 2). The MTP FIBTEM A10 value, shown to be correlated with fibrinogen concentration, remains high over 35 days, with only some values on D35 dropping into the normal range (Fig 3; means at D0=35.75mm and D35=26.63; ref. range=9-24). A10 and G were highly correlated (r=.812, p=.008). FVIII activity in cryo declined from 9-fold above average plasma levels over 35 days to approximately 25% of its starting activity. Surprisingly, the drop in FVIII was not correlated with clotting time (CT) in the EXTEM (r=-.335, p=.739), and CT was either faster than or within normal references ranges for whole blood at all time points (Fig 4; slowest median CT=49.5s, ref. range=42-72). The change in CT was correlated with measured peak thrombin levels (Fig 5; r=-.883, p=.002), although FVIII was not correlated with peak thrombin generation (r=.403, p=.282). vWF activity of cryo initially increased as has been previously reported but declined to baseline level by D7 and further through D35. vWF activity was correlated with the rate of platelet adhesion to a collagen surface under arterial flow (Fig 6; r=.677, p=.045). Discussion Cryo is mainly used in resuscitation of severe hemorrhage in MTP. It contributes to hemostasis by providing vWF to support platelet adhesion and primary hemostasis, FVIII to augment thrombin generation, and fibrinogen as clot substrate. Standard coagulation assays such as PT and aPTT or isolated factor activity assays are inadequate for evaluating the contribution of cryo to global MTP performance. The data presented here, derived from multiple functional tests including ROTEM, CAT, ristocetin cofactor assay, and Bioflux, show that thawed cryoprecipitate stored at 4°C is functionally viable for up to 35 days; as part of a massive transfusion protocol. It supports clot strength, thrombin generation, and platelet adhesion. Adoption of an extended shelf life for thawed cryo would reduce waste and increase availability for treatment of hemorrhage. Disclosures No relevant conflicts of interest to declare.


ACS Nano ◽  
2021 ◽  
Author(s):  
Enrique Valera ◽  
Aaron Jankelow ◽  
Jongwon Lim ◽  
Victoria Kindratenko ◽  
Anurup Ganguli ◽  
...  

2021 ◽  
pp. 104063872110018
Author(s):  
Justin R. Perrault ◽  
Michael D. Arendt ◽  
Jeffrey A. Schwenter ◽  
Julia L. Byrd ◽  
Kathryn A. Tuxbury ◽  
...  

Blood glucose measurements provide important diagnostic information regarding stress, disease, and nutritional status. Glucose analytical methodologies include dry chemistry analysis (DCA) of plasma and point-of-care (POC) glucometer analysis of whole blood; however, these 2 methods differ in cost, required sample volume, and processing time. Because POC glucometers use built-in equations based on features of mammalian blood to convert whole blood measurements to plasma equivalent units, obtained glucose data must be compared and validated using gold-standard chemistry analytical methodology in reptiles. For in-water, trawl-captured, immature Kemp’s ridley sea turtles ( Lepidochelys kempii) from Georgia, USA, we observed significant, positive agreement between the 2 glucose determination methods; however, the glucometer overestimated glucose concentrations by 1.4 mmol/L on average in comparison to DCA and produced a wider range of results. The discordance of these results suggests that POC glucometer glucose data should be interpreted in the context of methodology- and brand-specific reference intervals along with concurrent packed cell volume data.