Engineering tumor vasculature on an injection-molded plastic array 3D culture (IMPACT) platform

Lab on a Chip ◽  
2019 ◽  
Vol 19 (12) ◽  
pp. 2071-2080 ◽  
Author(s):  
Somin Lee ◽  
Jungeun Lim ◽  
James Yu ◽  
Jungho Ahn ◽  
Younggyun Lee ◽  
...  

Recent advances in microfluidic organ-on-a-chip technology have enabled the growth of 3D microphysiological systems for diverse biological studies.

Lab on a Chip ◽  
2018 ◽  
Vol 18 (16) ◽  
pp. 2433-2440 ◽  
Author(s):  
Younggyun Lee ◽  
Jin Woo Choi ◽  
James Yu ◽  
Dohyun Park ◽  
Jungmin Ha ◽  
...  

A versatile injection-molded platform with fast, robust, and simple liquid patterning capable of 3D co-culture experiments.


Micromachines ◽  
2021 ◽  
Vol 12 (9) ◽  
pp. 1106
Author(s):  
Di Wang ◽  
Ye Cong ◽  
Quanfeng Deng ◽  
Xiahe Han ◽  
Suonan Zhang ◽  
...  

The pathogenesis of respiratory diseases is complex, and its occurrence and development also involve a series of pathological processes. The present research methods are have difficulty simulating the natural developing state of the disease in the body, and the results cannot reflect the real growth state and function in vivo. The development of microfluidic chip technology provides a technical platform for better research on respiratory diseases. The size of its microchannel can be similar to the space for cell growth in vivo. In addition, organ-on-a-chip can achieve long-term co-cultivation of multiple cells and produce precisely controllable fluid shear force, periodically changing mechanical force, and perfusate with varying solute concentration gradient. To sum up, the chip can be used to analyze the specific pathophysiological changes of organs meticulously, and it is widely used in scientific research on respiratory diseases. The focus of this review is to describe and discuss current studies of artificial respiratory systems based on organ-on-a-chip technology and to summarize their applications in the real world.


2021 ◽  
Vol 1019 ◽  
pp. 205-210
Author(s):  
Deepika S. Singraur ◽  
Bhushan T. Patil ◽  
Vasim A. Shaikh

The cooling process is an essential aspect while designing for uniform heat transfer between the mold and the molded part. Improper design and placement of cooling channels result in non-uniform cooling and thus results in differential shrinkage and warpage on the final product. The installation of the channels yet plays a crucial role in the cooling of the part. Conforming channels that are placed at an optimum distance from the part to enhance the cooling process. In this paper, the performance parameters of straight drilled channels are compared with the conformal cooling channels for an electric alarm box. The analysis indicates that the conformal cooling method improved and enhanced the cooling process and reduced the defects like warpage and differential shrinkage by 25.5% and 28.0% respectively.


2020 ◽  
Vol 245 (13) ◽  
pp. 1155-1162 ◽  
Author(s):  
Sandra H Blumenrath ◽  
Bo Y Lee ◽  
Lucie Low ◽  
Ranjini Prithviraj ◽  
Danilo Tagle

Technological advances with organs-on-chips and induced pluripotent stem cells promise to overcome hurdles associated with developing medical products, especially for rare diseases. Organs-on-chips—bioengineered “microphysiological systems” that mimic human tissue and organ functionality—may overcome clinical trial challenges with real-world patients by offering ways to conduct “clinical trials-on-chips” (CToCs) to inform the design and implementation of rare disease clinical studies in ways not possible with other culture systems. If applied properly, CToCs can substantially impact clinical trial design with regard to anticipated key outcomes, assessment of clinical benefit and risk, safety and tolerability profiles, population stratification, value and efficiency, and scalability. To discuss how tissue chips are best used to move the development of rare disease therapies forward, a working group of experts from industry, academia, and FDA as well as patient representatives addressed questions related to disease setting, test agents for microphysiological systems, study design and feasibility, data collection and use, the benefits and risks associated with this approach, and how to engage stakeholders. While rare diseases with no current therapies were considered the ultimate target, participants cautioned against stepping onto too many unknown territories when using rare disease as initial test beds. Among the disease categories considered ideal for initial CToC tests were well-defined diseases with known clinical outcomes; diseases where tissues on chips can serve as an alternative to risky first-in-human studies, such as in pediatric oncology; and diseases that lend itself to immuno-engineering or genome editing. Participants also considered important challenges, such as hosting the chip technology in-house, the high variability of cell batches and the resulting regulatory concerns, as well as the financial risk associated with the new technology. To make progress in this area and increase confidence with the use of tissue chips, the re-purposing of approved drugs ought to be the very first step. Impact statement Designing and conducting clinical trials are extremely difficult in rare diseases. Adapting tissue chips for rare disease therapy development is pivotal in assuring that treatments are available, especially for severe diseases that are difficult to treat. Thus far, the NCATS-led National Institutes of Health (NIH) Tissue Chip program has focused on deploying the technology towards in vitro tools for safety and efficacy assessments of therapeutics. However, exploring the feasibility and best possible approach to expanding this focus towards the development phase of therapeutics is critical to moving the field of CToCs forward and increasing confidence with the use of tissue chips. The working group of stakeholders and experts convened by NCATS and the Drug Information Association (DIA) addresses important questions related to disease setting, test agents, study design, data collection, benefit/risk, and stakeholder engagement—exploring both current and future best use cases and important prerequisites for progress in this area.


Science ◽  
2019 ◽  
Vol 364 (6444) ◽  
pp. 960-965 ◽  
Author(s):  
Sunghee Estelle Park ◽  
Andrei Georgescu ◽  
Dongeun Huh

Recent studies have demonstrated an array of stem cell–derived, self-organizing miniature organs, termed organoids, that replicate the key structural and functional characteristics of their in vivo counterparts. As organoid technology opens up new frontiers of research in biomedicine, there is an emerging need for innovative engineering approaches for the production, control, and analysis of organoids and their microenvironment. In this Review, we explore organ-on-a-chip technology as a platform to fulfill this need and examine how this technology may be leveraged to address major technical challenges in organoid research. We also discuss emerging opportunities and future obstacles for the development and application of organoid-on-a-chip technology.


Micromachines ◽  
2019 ◽  
Vol 11 (1) ◽  
pp. 50 ◽  
Author(s):  
Hashemzadeh ◽  
Allahverdi ◽  
Ghorbani ◽  
Soleymani ◽  
Kocsis ◽  
...  

Organ-on-a-chip technology has gained great interest in recent years given its ability to control the spatio-temporal microenvironments of cells and tissues precisely. While physical parameters of the respective niche such as microchannel network sizes, geometric features, flow rates, and shear forces, as well as oxygen tension and concentration gradients, have been optimized for stem cell cultures, little has been done to improve cell-matrix interactions in microphysiological systems. Specifically, detailed research on the effect of matrix elasticity and extracellular matrix (ECM) nanotopography on stem cell differentiation are still in its infancy, an aspect that is known to alter a stem cell’s fate. Although a wide range of hydrogels such as gelatin, collagen, fibrin, and others are available for stem cell chip cultivations, only a limited number of elasticities are generally employed. Matrix elasticity and the corresponding nanotopography are key factors that guide stem cell differentiation. Given this, we investigated the addition of gold nanowires into hydrogels to create a tunable biointerface that could be readily integrated into any organ-on-a-chip and cell chip system. In the presented work, we investigated the matrix elasticity (Young’s modulus, stiffness, adhesive force, and roughness) and nanotopography of gold nanowire loaded onto fibrin hydrogels using the bio-AFM (atomic force microscopy) method. Additionally, we investigated the capacity of human amniotic mesenchymal stem cells (hAMSCs) to differentiate into osteo- and chondrogenic lineages. Our results demonstrated that nanogold structured-hydrogels promoted differentiation of hAMSCs as shown by a significant increase in Collagen I and II production. Additionally, there was enhanced calcium mineralization activity and proteoglycans formation after a cultivation period of two weeks within microfluidic devices.


Author(s):  
Morimasa Nakamura ◽  
Atsushi Katayama ◽  
Ichiro Moriwaki

A hot-roll finishing was proposed as a simple finishing method for plastic gears. In the hot-roll finishing, plastic work gears are finished by meshing with a heated copper die wheel. In the previous study, a hot-roll finishing rig for plastic gears was developed, and it was confirmed that tooth profiles of hobbed plastic gears are improved by the finishing. Thus, the hot-roll finishing could also be effective for injection-molded plastic gears. In the present paper, appropriate hot-roll finishing procedures for injection-molded polyoxymethylene (POM) helical gears were pursued. In the injection molding, an inadequate mold easily allows large slope deviations on a tooth profile and trace. The hot-roll finishing can reduce the slope deviations, but induces form deviations especially on the profile. Tests of injection-molded and hot-roll-finished plastic gears were performed on a self-produced gear roller test rig and a self-produced fatigue rig, and a transmission error and load capacity were estimated. Compared with injection-molded gears, hot-roll-finished plastic gears showed small transmission error, while a load capacity was at the almost same level. As a result, the hot-roll finishing is effective for improving a transmission error of injection-molded plastic gears.


Sign in / Sign up

Export Citation Format

Share Document