PdO/PdO2 functionalized ZnO : Pd films for lower operating temperature H2 gas sensing

Nanoscale ◽  
2018 ◽  
Vol 10 (29) ◽  
pp. 14107-14127 ◽  
Author(s):  
Oleg Lupan ◽  
Vasile Postica ◽  
Mathias Hoppe ◽  
Niklas Wolff ◽  
Oleksandr Polonskyi ◽  
...  

The improved hydrogen gas sensing performances of PdO-functionalized ZnO : Pd films compared to pristine ZnO : Pd are successfully reported in this work. The functionalized samples showed excellent sensing properties.

2018 ◽  
Vol 43 (50) ◽  
pp. 22756-22764 ◽  
Author(s):  
Stanislav Haviar ◽  
Jiří Čapek ◽  
Šárka Batková ◽  
Nirmal Kumar ◽  
Filip Dvořák ◽  
...  

2012 ◽  
Vol 4 (3) ◽  
pp. 1656-1665 ◽  
Author(s):  
Lucky M. Sikhwivhilu ◽  
Siyasanga Mpelane ◽  
Bonex W. Mwakikunga ◽  
Suprakas Sinha Ray

2019 ◽  
Vol 806 ◽  
pp. 1052-1059 ◽  
Author(s):  
Zhong Li ◽  
ZhengJun Yao ◽  
Azhar Ali Haidry ◽  
Tomas Plecenik ◽  
Branislav Grancic ◽  
...  

2012 ◽  
Vol 258 (20) ◽  
pp. 7839-7843 ◽  
Author(s):  
J. Sithole ◽  
B.D. Ngom ◽  
S. Khamlich ◽  
E. Manikanadan ◽  
N. Manyala ◽  
...  

2016 ◽  
Vol 42 (9) ◽  
pp. 11490-11495 ◽  
Author(s):  
Muhammad Mansha ◽  
Ahsanulhaq Qurashi ◽  
Nisar Ullah ◽  
Fatai Olawale Bakare ◽  
Ibrahim Khan ◽  
...  

2017 ◽  
Vol 24 (Supp02) ◽  
pp. 1850024 ◽  
Author(s):  
MALIHEH SABERI ◽  
ALI AKBAR ASHKARRAN

Tungsten-doped TiO2 gas sensors were successfully synthesized using sol–gel process and spin coating technique. The fabricated sensor was characterized by field emission scanning electron microscopy (FE-SEM), ultraviolet visible (UV–Vis) spectroscopy, transmission electron microscopy (TEM), X-Ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy. Gas sensing properties of pristine and tungsten-doped TiO2 nanolayers (NLs) were probed by detection of CO2 gas. A series of experiments were conducted in order to find the optimum operating temperature of the prepared sensors and also the optimum value of tungsten concentration in TiO2 matrix. It was found that introducing tungsten into the TiO2 matrix enhanced the gas sensing performance. The maximum response was found to be (1.37) for 0.001[Formula: see text]g tungsten-doped TiO2 NLs at 200[Formula: see text]C as an optimum operating temperature.


2020 ◽  
Vol 271 ◽  
pp. 127716
Author(s):  
Xiaoguang San ◽  
Yiming Lu ◽  
Guosheng Wang ◽  
Dan Meng ◽  
Xiaohui Gong ◽  
...  

2010 ◽  
Vol 21 (16) ◽  
pp. 165503 ◽  
Author(s):  
Young Tack Lee ◽  
Jun Min Lee ◽  
Yeon Ju Kim ◽  
Jin Hyoun Joe ◽  
Wooyoung Lee

2016 ◽  
Vol 22 (4) ◽  
pp. 730-736 ◽  
Author(s):  
Sunghoon Park ◽  
Hyejoon Kheel ◽  
Gun-Joo Sun ◽  
Hyoun Woo Kim ◽  
Taegyung Ko ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document