High performance Al–AlN solar spectrally selective coatings with a self-assembled nanostructure AlN anti-reflective layer

2017 ◽  
Vol 5 (6) ◽  
pp. 2852-2860 ◽  
Author(s):  
Chengbing Wang ◽  
Wei Cheng ◽  
Pengjun Ma ◽  
Rongbin Xia ◽  
Xiaoming Ling

The almost super-hydrophobic nanostructure AlN anti-reflective layer can effectively enhance light absorption and prevent surface contamination of Al–AlN absorber coatings.

Author(s):  
Qian-Yu Wang ◽  
Zheng-Min Zhang ◽  
Lin Liu ◽  
Lu Bai ◽  
Rui-Ying Bao ◽  
...  

Poly(L-lactide) (PLA)/TiO2/Pt composite fiber membrane with internal porous channel structure is fabricated by skillfully tuning the breath figure mechanism and vapor induced phase separation mechanism with solute and solvent matching...


2021 ◽  
pp. 107815522110235
Author(s):  
Hao ML ◽  
Wang T ◽  
Zhu JQ ◽  
Song YJ ◽  
Gong TJ ◽  
...  

Objectives The aims of the study were to evaluate the external contamination of hazardous drug vials used in Chinese hospitals and to compare environmental contamination generated by a robotic intelligent dispensing system (WEINAS) and a manual compounding procedure using a biological safety cabinet (BSC). Methods Cyclophosphamide, fluorouracil, and gemcitabine were selected as the representative hazardous drugs to monitor surface contamination of vials. In the comparative analysis of environmental contamination from manual and robotic compounding, wipe samples were taken from infusion bags, gloves, and the different locations of the BSC and the WEINAS robotic system. In this study, high-performance liquid chromatography coupled with double mass spectrometer (HPLC-MS/MS) was employed for sample analysis. Results (1) External contamination was measured on vials of all three hazardous drugs. The contamination detected on fluorouracil vials was the highest with an average amount up to 904.33 ng/vial, followed by cyclophosphamide (43.51 ng/vial), and gemcitabine (unprotected vials of 5.92 ng/vial, protected vials of 0.66 ng/vial); (2) overall, the environmental contamination induced by WEINAS robotic compounding was significantly reduced compared to that by manual compounding inside the BSC. Particularly, compared with manual compounding, the surface contamination on the infusion bags during robotic compounding was nearly nine times lower for cyclophosphamide (10.62 ng/cm2 vs 90.43 ng/cm2), two times lower for fluorouracil (3.47 vs 7.52 ng/cm2), and more than 23 times lower for gemcitabine (2.61 ng/cm2 vs 62.28 ng/cm2). Conclusions The external contamination occurred extensively on some hazardous drug vials that commonly used in Chinese hospitals. Comparison analysis for both compounding procedures revealed that robotic compounding can remarkably reduce environmental contamination.


2020 ◽  
Vol 8 (27) ◽  
pp. 13619-13629 ◽  
Author(s):  
Asif Abdullah Khan ◽  
Md Masud Rana ◽  
Guangguang Huang ◽  
Nanqin Mei ◽  
Resul Saritas ◽  
...  

A high-performance perovskite/polymer piezoelectric nanogenerator for next generation self-powered wireless micro/nanodevices.


2021 ◽  
pp. 130660
Author(s):  
Ji-Shi Wei ◽  
Ze-Yang Zhu ◽  
Xiao Zhao ◽  
Tian-Bing Song ◽  
Jian-Hang Huang ◽  
...  

2017 ◽  
Vol 41 (20) ◽  
pp. 11955-11961 ◽  
Author(s):  
Haoyuan Wang ◽  
Xia Kong ◽  
Shuai Zhao ◽  
Junshi Wu ◽  
Xiyou Li ◽  
...  

High-sensitive, quick-response room-temperature sensor to NO2 and NH3 is developed, based on QLS film of a new amphiphilic tris(phthalocyaninato) europium.


Nano Letters ◽  
2007 ◽  
Vol 7 (1) ◽  
pp. 22-27 ◽  
Author(s):  
Ralf Thomas Weitz ◽  
Ute Zschieschang ◽  
Franz Effenberger ◽  
Hagen Klauk ◽  
Marko Burghard ◽  
...  

RSC Advances ◽  
2017 ◽  
Vol 7 (42) ◽  
pp. 26120-26124 ◽  
Author(s):  
Chunde Wang ◽  
Yinyin Qian ◽  
Jing Yang ◽  
Shiqi Xing ◽  
Xu Ding ◽  
...  

We demonstrate that ternary NiCoP nanoparticles can be self-assembled on graphene at room temperature by a solution-phase method and our electrode materials exhibit a high performance for LIBs and supercapacitors.


Sign in / Sign up

Export Citation Format

Share Document