A diketopyrrolopyrrole-based fluorescence turn-on probe for the detection of Pb2+in aqueous solution and living cells

RSC Advances ◽  
2016 ◽  
Vol 6 (57) ◽  
pp. 52004-52008 ◽  
Author(s):  
Xiaofeng Yang ◽  
Yan Zhang ◽  
Yexin Li ◽  
Xiaolei Liu ◽  
Jiaxin Mao ◽  
...  

A diketopyrrolopyrrole-based fluorescent probeDPP-HBTbearing a benzothiazole hydrazone motif exhibited an obvious fluorescent turn-on response toward Pb2+ions with a low detection limit of 2.3 × 10−10M in aqueous solution.

2013 ◽  
Vol 295-298 ◽  
pp. 475-478 ◽  
Author(s):  
Zhi Xiang Han ◽  
Ming Hui Du ◽  
Guo Xi Liang ◽  
Xiang Yang Wu

Rhodamine B thiohydrazide (RBS) was firstly employed as turn-on fluorescent probe for hypochlorite in aqueous solution and living cells. It exhibits a stable response to hypochlorite from 1.0×10-6to 1.0×10-5M with a detection limit of 3.3×10-7M. The response of this probe to hypochlorite is fast and highly selective compared with other reactive oxygen species (such as.OH,1O2, H2O2) and other common anions (such as X-, ClO2-, ClO4-, NO3-, NO2-, OH-, Ac-, CO32-, SO42-).


2018 ◽  
Vol 42 (7) ◽  
pp. 5540-5547 ◽  
Author(s):  
Nirawit Kaewnok ◽  
Anuwut Petdum ◽  
Jitnapa Sirirak ◽  
Adisri Charoenpanich ◽  
Waraporn Panchan ◽  
...  

The sensor provides Cu2+-sensitive with low detection limit and very large Stokes shift, and can induce the emission in the HepG2 cellular system.


2014 ◽  
Vol 50 (19) ◽  
pp. 2498-2501 ◽  
Author(s):  
Qiaoling Liu ◽  
Lixia Feng ◽  
Caixia Yuan ◽  
Lin Zhang ◽  
Shaomin Shuang ◽  
...  

A bifluorophoric probe displays high selectivity for Cd2+ and a low detection limit of 20 nM Cd2+ in aqueous solution.


2014 ◽  
Vol 9 (12) ◽  
pp. 3397-3402 ◽  
Author(s):  
Hio-Ieng Un ◽  
Chang-Bo Huang ◽  
Junhai Huang ◽  
Chusen Huang ◽  
Ti Jia ◽  
...  

2020 ◽  
Vol 44 (28) ◽  
pp. 12019-12026 ◽  
Author(s):  
Divya Singhal ◽  
Ismail Althagafi ◽  
Ashish Kumar ◽  
Saroj Yadav ◽  
Ashok K. Prasad ◽  
...  

Thieno[3,2-c]pyran was synthesized as a fluorescent turn-on chemosensor for the selective recognition of Zn2+ ions with a low detection limit (0.67 μM), and it also exhibited AIE properties.


2020 ◽  
Vol 44 (45) ◽  
pp. 19642-19649
Author(s):  
Lingjie Hou ◽  
Tao Liu ◽  
Yaling Gong ◽  
Jin Li ◽  
Chenhua Deng ◽  
...  

A Schiff base fluorescent probe, namely naphthalic anhydride – (2-pyridine) hydrazone (NAH), has been synthesized and developed for the highly selective and sensitive monitoring of Fe3+ ions in an aqueous solution and living cells.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Xiaohua Ma ◽  
Guoguang Wu ◽  
Yuehua Zhao ◽  
Zibo Yuan ◽  
Yu Zhang ◽  
...  

We reported here a turn-on fluorescent probe (1) for the detection of cysteine (Cys) by incorporating the recognition unit of 2,4-dinitrobenzenesulfonyl ester (DNBS) to a coumarin derivative. The structure of the obtained probe was confirmed by NMR and HRMS techniques. The probe shows a remarkable fluorescence off-on response (∼52-fold) by the reaction with Cys in 100% aqueous buffer. The sensing mechanism was verified by the HPLC test. Probe 1 also displays high selectivity towards Cys. The detection limit was calculated to be 23 nM. Moreover, cellular experiments demonstrated that the probe is highly biocompatible and can be used for monitoring intracellular Cys.


Author(s):  
Yanpeng Dai ◽  
Jiaxin Fu ◽  
Kun Yao ◽  
Qianqian Song ◽  
Kuoxi Xu ◽  
...  

RSC Advances ◽  
2014 ◽  
Vol 4 (81) ◽  
pp. 43110-43113 ◽  
Author(s):  
Jiayu Zha ◽  
Boqiao Fu ◽  
Caiqin Qin ◽  
Lintao Zeng ◽  
Xichao Hu

A novel fluorescent probe displayed a colorimetric response to ClO− with high selectivity, fast response and a low detection limit (0.08 μM).


Sign in / Sign up

Export Citation Format

Share Document