A novel 3,6-diamino-1,8-naphthalimide derivative as a highly selective fluorescent “turn-on” probe for thiols

RSC Advances ◽  
2015 ◽  
Vol 5 (42) ◽  
pp. 32990-32993 ◽  
Author(s):  
Cheng Dong ◽  
Chun-Qiong Zhou ◽  
Jian-Wei Yang ◽  
Ting-Cong Liao ◽  
Jin-Xiang Chen ◽  
...  

A novel 3,6-diamino-1,8-naphthalimide-based fluorescent “turn-on” probe exhibited high selectivity and low detection limit toward Cys.

Author(s):  
Ziyu Wang ◽  
Meiyun Xu ◽  
Nan Zhang ◽  
Jian-Bin Pan ◽  
Xinqi Wu ◽  
...  

A mechanism of co-reactive group poisoning (CGP) was discovered for designing efficient I2 vapor sensors for early warning of a nuclear emergency, which give an ultra-low detection limit of 0.13 ppt as well as high selectivity.


2013 ◽  
Vol 295-298 ◽  
pp. 475-478 ◽  
Author(s):  
Zhi Xiang Han ◽  
Ming Hui Du ◽  
Guo Xi Liang ◽  
Xiang Yang Wu

Rhodamine B thiohydrazide (RBS) was firstly employed as turn-on fluorescent probe for hypochlorite in aqueous solution and living cells. It exhibits a stable response to hypochlorite from 1.0×10-6to 1.0×10-5M with a detection limit of 3.3×10-7M. The response of this probe to hypochlorite is fast and highly selective compared with other reactive oxygen species (such as.OH,1O2, H2O2) and other common anions (such as X-, ClO2-, ClO4-, NO3-, NO2-, OH-, Ac-, CO32-, SO42-).


2016 ◽  
Vol 40 (3) ◽  
pp. 1930-1934 ◽  
Author(s):  
M. Raju ◽  
Tapasya J. Patel ◽  
Ratish R. Nair ◽  
Pabitra B. Chatterjee

Synopsis: A well-known tryptophan metabolite, xanthurenic acid, a natural non-fluorescent intermediate siderophore, showed a very selective turn-on response to K+ over other competing metal ions and the detection limit of this natural ionophore was found to be 53 nM at physiological pH.


2021 ◽  
Author(s):  
Hongtao Li ◽  
Yuting Zhang ◽  
Yan Huang ◽  
Dapeng Cao ◽  
Shitao Wang

We developed a small organic molecule, the 1,3,6,8-Tetrakis(pbenzoic acid)pyrene (TBAPy) as a facile turn-on fluorescence probe for selectively detecting the basic protein protamine in water with a low detection limit...


2020 ◽  
Vol 44 (28) ◽  
pp. 12019-12026 ◽  
Author(s):  
Divya Singhal ◽  
Ismail Althagafi ◽  
Ashish Kumar ◽  
Saroj Yadav ◽  
Ashok K. Prasad ◽  
...  

Thieno[3,2-c]pyran was synthesized as a fluorescent turn-on chemosensor for the selective recognition of Zn2+ ions with a low detection limit (0.67 μM), and it also exhibited AIE properties.


2018 ◽  
Vol 42 (24) ◽  
pp. 19450-19457 ◽  
Author(s):  
Nannan Jian ◽  
Kaiwen Lin ◽  
Bin Guo ◽  
Ge Zhang ◽  
Ximei Liu ◽  
...  

Electrosynthesized oligo(1-pyrenesulfonic acid) displays high selectivity, low detection limit and outstanding reversibility in the detection of Fe3+ in aqueous solution.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Xiaohua Ma ◽  
Guoguang Wu ◽  
Yuehua Zhao ◽  
Zibo Yuan ◽  
Yu Zhang ◽  
...  

We reported here a turn-on fluorescent probe (1) for the detection of cysteine (Cys) by incorporating the recognition unit of 2,4-dinitrobenzenesulfonyl ester (DNBS) to a coumarin derivative. The structure of the obtained probe was confirmed by NMR and HRMS techniques. The probe shows a remarkable fluorescence off-on response (∼52-fold) by the reaction with Cys in 100% aqueous buffer. The sensing mechanism was verified by the HPLC test. Probe 1 also displays high selectivity towards Cys. The detection limit was calculated to be 23 nM. Moreover, cellular experiments demonstrated that the probe is highly biocompatible and can be used for monitoring intracellular Cys.


RSC Advances ◽  
2014 ◽  
Vol 4 (87) ◽  
pp. 47076-47080 ◽  
Author(s):  
Dipratn G. Khandare ◽  
Hrishikesh Joshi ◽  
Mainak Banerjee ◽  
Mahesh S. Majik ◽  
Amrita Chatterjee

An aggregation-induced emission (AIE) based “turn-on” fluorescent chemodosimeter for selective detection of Pb2+ ions has been developed. The probe is a phosphate functionalized tetraphenylethylene derivative and the resulting lead–TPE complex has very low solubility in working solvent and triggers AIE and shows a low detection limit of 10 ppb.


RSC Advances ◽  
2014 ◽  
Vol 4 (81) ◽  
pp. 43110-43113 ◽  
Author(s):  
Jiayu Zha ◽  
Boqiao Fu ◽  
Caiqin Qin ◽  
Lintao Zeng ◽  
Xichao Hu

A novel fluorescent probe displayed a colorimetric response to ClO− with high selectivity, fast response and a low detection limit (0.08 μM).


The Analyst ◽  
2015 ◽  
Vol 140 (9) ◽  
pp. 3285-3289 ◽  
Author(s):  
Fang Liu ◽  
Changqin Ding ◽  
Ming Jin ◽  
Yang Tian

A two-photon fluorescent sensor ATD was developed for Hg2+ determination with high selectivity and low detection limit, in which two-photon fluorophore TD was designed and synthesized with a specific recognition molecule for Hg2+ – PT.


Sign in / Sign up

Export Citation Format

Share Document