Surface molecular imprinting on CdTe quantum dots for fluorescence sensing of 4-nitrophenol

2016 ◽  
Vol 8 (10) ◽  
pp. 2226-2232 ◽  
Author(s):  
Linye Jiang ◽  
Haijian Liu ◽  
Ming Li ◽  
Yue Xing ◽  
Xueqin Ren

The developed fluorescent sensor provides high sensitivity and selectivity and a lower detection limit than previously developed sensors.

2021 ◽  
Author(s):  
Yu Liu ◽  
Yan Wang ◽  
Xiao-Sa Zhang ◽  
Yu-Shu Sheng ◽  
Wen-Ze Li ◽  
...  

A Zn-CP exhibits remarkable fluorescence behaviours and stability in a wide range of pH values. It can become an outstanding candidate in the selective sensing of Fe3+, Mg2+, Cr2O72−, MnO4−, NB and NM at a lower detection limit.


Sensors ◽  
2020 ◽  
Vol 20 (5) ◽  
pp. 1429
Author(s):  
Sylwia Baluta ◽  
Karol Malecha ◽  
Agnieszka Świst ◽  
Joanna Cabaj

A novel fluorescence-sensing pathway for epinephrine (EP) detection was investigated. The ceramic-based miniature biosensor was developed through the immobilization of an enzyme (laccase, tyrosinase) on a polymer—poly-(2,6-di([2,2′-bithiophen]-5-yl)-4-(5-hexylthiophen-2-yl)pyridine), based on low temperature cofired ceramics technology (LTCC). The detection procedure was based on the oxidation of the substrate, i.e., in the presence of the enzyme. An alternative enzyme-free system utilized the formation of a colorful complex between Fe2+ ions and epinephrine molecules. With the optimized conditions, the analytical performance illustrated high sensitivity and selectivity in a broad linear range with a detection limit of 0.14–2.10 nM. Moreover, the strategy was successfully used for an EP injection test with labeled pharmacological samples.


2017 ◽  
Vol 5 (31) ◽  
pp. 6300-6306 ◽  
Author(s):  
Lin Cao ◽  
Xiangqing Li ◽  
Lixia Qin ◽  
Shi-Zhao Kang ◽  
Guodong Li

A new class of Cyt c detection fluorescence sensor based on graphene quantum dots supported by graphene oxide has been facilely developed. The sensor shows a high sensitivity and selectivity for Cyt c detection, and further exhibits favorable intracellular imaging in A549 cells.


2021 ◽  
Vol 21 (5) ◽  
pp. 3059-3064
Author(s):  
A. K. M. Kafi ◽  
Aizam Bin Kasri ◽  
Rajan Jose

The fabrication of a network of glucose oxidase-horseradish peroxidase/tin oxide (GOx-HRP/SnO2), immobilized onto a glassy carbon electrode (GCE) and its utilization as a biosensor for glucose detection is reported. The network established with GOx-HRP/SnO2 possess high sensitivity and stability by performing the electrocatalytic features in the sensing of glucose. The turbidity of fabrication had been scanned and analyzed using UV-vis spectroscopy. The morphology and composition of the fabricated GOx-HRP/SnO2 networks were characterized by scanning electron microscopy (SEM). Cyclic voltammetry and amperometry were employed to study the electrochemical properties of the proposed biosensor. The effect of applied electrode potential and pH were systemically investigated. The biosensor responds to glucose at work potential values between −400 mV, and exhibited a lower detection limit (0.025 mM) and long linear range (0.25 to 7.0 mM), and was resistant to common interferences.


CrystEngComm ◽  
2021 ◽  
Author(s):  
Yang Qiao ◽  
Zeqi Li ◽  
Mei-Hui Yu ◽  
Ze Chang ◽  
Xian-He Bu

High sensitivity and selectivity for detection of metal ions are very important to protect human health. Fluorescent metal-organic framework (MOF) as a new sensing material has attracted more and more...


1974 ◽  
Vol 20 (9) ◽  
pp. 1181-1186 ◽  
Author(s):  
Jorge Lizana ◽  
Kristoffer Hellsing

Abstract A manual immunonephelometric method for proteins has been developed by using an ordinary fluorometer as a nephelometer. By applying the enhancing effect of polyethylene glycol (av mol wt, 6000) on the immunological reaction, albumin and fibrinogen were quantitated after a 10-min reaction time. Under the present conditions the sensitivity was increased and thus antiserum consumption was decreased. The reaction conditions were carefully studied with respect to optimal time and concentration of the reactants. The precision of the method was 2.6-3.6% (CV). The lower detection limit in the albumin-antialbumin system was 0.1 mg/liter. Comparative studies showed a correlation coefficient of 0.991 with an automated immunonephelometric method for urinary albumin, and of 0.908 with a thrombin clottable method for plasma fibrinogen. We especially suggest use of this manual immunonephelometric method where small series of samples are to be analyzed.


2019 ◽  
Vol 7 (44) ◽  
pp. 7033-7041 ◽  
Author(s):  
Sansan Shen ◽  
Bohui Huang ◽  
Xiaofeng Guo ◽  
Hong Wang

An on–off–on fluorescent sensor based on N-SiQD has the advantages of fast response time and high sensitivity to Hg2+ and GSH.


1995 ◽  
Vol 41 (7) ◽  
pp. 986-990 ◽  
Author(s):  
U Piran ◽  
W J Riordan ◽  
L A Livshin

Abstract We developed a novel noncompetitive immunoassay format for monoepitopic analytes and describe here a model assay for triiodothyronine (T3), performed on Ciba Corning's ACS:180 analyzer. Acridinium ester (AE)-labeled bivalent anti-T3 was incubated with the sample, producing AE-anti-T3/T3 complexes and unreacted AE-anti-T3. Controlled-pore glass particles (CPG) with immobilized diiodothyronine (T2) were then added in excess, to bind AE-anti-T3 possessing two unoccupied binding sites but not AE-anti-T3 bound to one or two T3 molecules. Paramagnetic particles (PMP) with immobilized anti-AE were then added to the same cuvette to capture AE-anti-T3/T3 complexes; AE-anti-T3 bound to the surface of CPG, however, was not captured, because of steric hindrance. After the incubation, the PMP was magnetically separated to remove the liquid phase and the suspended CPG from the cuvette. The chemiluminescence associate with the PMP remaining in the cuvette was then measured. This noncompetitive T3 assay exhibited a 10-fold lower detection limit than the equivalent competitive T3 assay, i.e., 0.3 vs pg/test. Imprecision (CV) in the clinically significant range was 6% or less. The assay also displayed two- to sevenfold lower cross-reactivities and a wider dynamic range.


Sign in / Sign up

Export Citation Format

Share Document