Nanoporous copper oxide ribbon assembly of free-standing nanoneedles as biosensors for glucose

The Analyst ◽  
2015 ◽  
Vol 140 (15) ◽  
pp. 5205-5215 ◽  
Author(s):  
Shaodong Sun ◽  
Yuexia Sun ◽  
Anran Chen ◽  
Xiaozhe Zhang ◽  
Zhimao Yang

Two-dimensional (2D) hierarchical nanoporous CuO ribbons were successfully synthesized by a green solution-phase route. They serve as a promising electrode material for nonenzymatic glucose detection and show high sensitivity, a low detection limit, fast amperometric response and good selectivity.

2016 ◽  
Vol 6 (1) ◽  
Author(s):  
R. B. Rakhi ◽  
Pranati Nayak ◽  
Chuan Xia ◽  
Husam N. Alshareef

Abstract A biosensor platform based on Au/MXene nanocomposite for sensitive enzymatic glucose detection is reported. The biosensor leverages the unique electrocatalytic properties and synergistic effects between Au nanoparticles and MXene sheets. An amperometric glucose biosensor is fabricated by the immobilization of glucose oxidase (GOx) enzyme on Nafion solubilized Au/ MXene nanocomposite over glassy carbon electrode (GCE). The biomediated Au nanoparticles play a significant role in facilitating the electron exchange between the electroactive center of GOx and the electrode. The GOx/Au/MXene/Nafion/GCE biosensor electrode displayed a linear amperometric response in the glucose concentration range from 0.1 to 18 mM with a relatively high sensitivity of 4.2 μAmM−1 cm−2 and a detection limit of 5.9 μM (S/N = 3). Furthermore, the biosensor exhibited excellent stability, reproducibility and repeatability. Therefore, the Au/MXene nanocomposite reported in this work is a potential candidate as an electrochemical transducer in electrochemical biosensors.


2021 ◽  
Author(s):  
Siddesh Umapathi ◽  
Harish Singh ◽  
Jahangir Masud ◽  
Manashi Nath

CuSe nanostructures exhibit high-efficiency for glucose detection with high sensitivity (19.419 mA mM−1 cm−2) and selectivity at low applied potential (0.15 V vs. Ag|AgCl), low detection limit (0.196 μM) and linear detection range (100 nM to 40 μM).


2020 ◽  
Vol 8 (5) ◽  
pp. 1008-1016 ◽  
Author(s):  
Haihan Zou ◽  
Dongyan Tian ◽  
Chao Lv ◽  
Songmei Wu ◽  
Guanxuan Lu ◽  
...  

Co–Ni ultrathin metal organic framework nanosheets exhibited extremely high sensitivity, wide linear range, low detection limit and excellent selectivity as a glucose sensing electrode material.


2020 ◽  
Vol 8 (25) ◽  
pp. 5411-5415 ◽  
Author(s):  
Yanxia Qiao ◽  
Qian Liu ◽  
Siyu Lu ◽  
Guang Chen ◽  
Shuyan Gao ◽  
...  

A glucose sensor based on a conductive Ni-MOF as an electrocatalyst exhibits a fast response time, low detection limit, and high sensitivity, and it can also be applied for the detection of glucose in blood serum samples.


2014 ◽  
Vol 2 (20) ◽  
pp. 7306-7312 ◽  
Author(s):  
Chuncai Kong ◽  
Linli Tang ◽  
Xiaozhe Zhang ◽  
Shaodong Sun ◽  
Shengchun Yang ◽  
...  

In this paper, we successfully fabricated a novel type of a hollow CuO polyhedron that consists of numerous nanoplates using Cu2O as a template. The hollow CuO polyhedron-modified electrode exhibits high sensitivity, low detection limit, good stability and fast response towards the oxidation of glucose, suggesting it to be a promising nonenzymatic glucose sensor.


2021 ◽  
Vol 154 (19) ◽  
pp. 194901
Author(s):  
Ge Zhang ◽  
Yuwen Zeng ◽  
Pavlo Gordiichuk ◽  
Michael S. Strano

Nano Letters ◽  
2021 ◽  
Author(s):  
Fei Zhou ◽  
Yang Li ◽  
Xingqi Liao ◽  
Shuren Lin ◽  
Haizeng Song ◽  
...  

Nanoscale ◽  
2021 ◽  
Author(s):  
Xianghui Zhang ◽  
Andre Beyer

The discovery of graphene has triggered a great interest in inorganic as well as molecular two-dimensional (2D) materials. In this review, we summarize recent progress in the mechanical characterization of...


Nanoscale ◽  
2021 ◽  
Author(s):  
Bingjun Yang ◽  
Jiangtao Chen ◽  
xiaonan Wu ◽  
Bao Liu ◽  
Lingyang Liu ◽  
...  

A facile method to produce MXene-TiO2 composite is demonstrated for enhanced field emission display applications. The field emission performance of two-dimensional free-standing and linear-shaped field emitters has been systematically investigated...


Sign in / Sign up

Export Citation Format

Share Document