Facile colorimetric detection of human chorionic gonadotropin based on the peptide-induced aggregation of gold nanoparticles

2015 ◽  
Vol 7 (1) ◽  
pp. 29-33 ◽  
Author(s):  
Chia-Chen Chang ◽  
Chen-Yu Chen ◽  
Chie-Pein Chen ◽  
Chii-Wann Lin

A facile and rapid optical detection method of human chorionic gonadotropin (hCG) was developed by using the hCG-binding peptide and the anti-aggregation of gold nanoparticles (AuNPs).

2014 ◽  
Vol 50 (92) ◽  
pp. 14443-14446 ◽  
Author(s):  
Chia-Chen Chang ◽  
Chie-Pein Chen ◽  
Chung-Han Lee ◽  
Chen-Yu Chen ◽  
Chii-Wann Lin

RSC Advances ◽  
2014 ◽  
Vol 4 (102) ◽  
pp. 58460-58466 ◽  
Author(s):  
Syazana Abdullah Lim ◽  
Hiroyuki Yoshikawa ◽  
Eiichi Tamiya ◽  
Hartini Mohd Yasin ◽  
Minhaz Uddin Ahmed

This study describes a highly sensitive electrochemical immunosensor for the detection of human chorionic gonadotropin (hCG) that uses gold nanoparticles (AuNP) as the electrochemical label and graphene as electrode material.


2014 ◽  
Vol 182 (3-4) ◽  
pp. 611-616 ◽  
Author(s):  
Zhengbo Chen ◽  
Chenmeng Zhang ◽  
Yuan Tan ◽  
Tianhui Zhou ◽  
He Ma ◽  
...  

Author(s):  
Catherine Massart ◽  
Catherine Lucas ◽  
Nathalie Rioux-Leclercq ◽  
Patricia Fergelot ◽  
Véronique Pouvreau-Quillien ◽  
...  

AbstractAssay of human chorionic gonadotropin (hCG) is mainly used for the detection and monitoring of pregnancy, and for the follow-up of trophoblastic tumors. The serum free β-hCG subunit (hCGβ) is also a tumor marker in many non-trophoblastic tumors, including gastrointestinal cancers. In this work, we compared the performance of several immunoassays for pregnancy exclusion before liver transplantation and in the follow-up of a woman with cholangiocarcinoma. Serum hCG was detected with the Abbott Testpack plus hCG-Combo and measured with four automated sandwich immunoassays: ADVIA-Centaur, ACS:180, AxSYM and Dimension. hCGβ was determined by an automated fluorescence sandwich immunoassay (Kryptor-Free β hCG) and with a specific immunoradiometric assay (ELSA-F β hCG, Schering). The expression of hCG was also evaluated by immunohistochemistry on sections of intrahepatic cholangiocarcinoma cells and on peritoneal metastases. Before transplantation, discordant results were observed for pregnancy exclusion. Qualitative Testpack and Dimension tests detected no hCG-like immunoreactivity, whereas the ADVIA-Centaur, ACS:180 and AxSYM tests revealed positive levels. The same discrepancy was obtained in follow-up of the patient after liver transplantation. hCGβ assay and immunohistochemical staining revealed tumor cell secretion of hCGβ. In conclusion, a specific serum immunoassay for intact dimeric hCG without cross-reaction with hCGβ should be adopted as routine policy for pregnancy exclusion before liver transplantation.


Sign in / Sign up

Export Citation Format

Share Document