Ionic liquid modified silica sorbent for simultaneous separation and preconcentration of heavy metals from water and tobacco samples prior to their determination by flame atomic absorption spectrometry

2012 ◽  
Vol 4 (9) ◽  
pp. 2879 ◽  
Author(s):  
Maysam Gharehbaghi ◽  
Farzaneh Shemirani
2018 ◽  
Vol 33 (2) ◽  
pp. 61
Author(s):  
M. Shabany ◽  
Ali Mohammad Haji Shabani ◽  
Shayessteh Dadfarnia ◽  
Alireza Gorji ◽  
S. H. Ahmadi

A procedure for separation and preconcentration of trace amounts of Zn(II) from aqueous media is proposed. The procedure is based on the adsorption of Zn2+ on octadecyl bonded silica membrane disk modified with N,N’-disalicylidene-1,2-phenylendiamine at pH 7. The retained zinc ions were then stripped from the disk with a minimal amount of 1.5 mol L-1 hydrochloric acid solution as eluent, and determined by flame atomic absorption spectrometry. Maximum capacity of the membrane disk modified with 5 mg of the ligand was found to be 226 μg Zn2+. The relative standard deviation of zinc for ten replicate extraction of 10 μg zinc from 1000 mL samples was 1.2%. The limit of detection of the proposed method was 14 ng of Zn2+ per 1000 mL. The method was successfully applied to the determination of zinc in natural water samples and accuracy was examined by recovery experiments and independent analysis by graphite furnace atomic absorption spectrometry (GFAAS).


2010 ◽  
Vol 7 (3) ◽  
pp. 278-283
Author(s):  
F. Ahmadia ◽  
A. Khanmohammadi ◽  
A. Malekpour

A cloud point extraction method was presented for preconcentration of copper in various samples. After complexation with 4-Amino-2,3-dimethyl-1-phenyl-3-pyrazoline-5-one (ADPP) or N-Benzoyl-N-phenylhydroxylamine (BPA)  in water, analyte ions are quantitatively extracted to the phase rich in Triton X-114 after centrifugation. 2.0 mol L-1 HNO3 solution in methanol was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The adopted concentrations for ADPP, Triton X-114, HNO3 and parameters such as bath temperature, centrifuge rate and time were optimized. Detection limits (3SDb/m) of 1.3 and 1.9 ng mL-1 for ADPP and BPA along with enrichment factors of 30 and 38 for ADPP and BPA were achieved. The high efficiency of cloud point extraction to carry out the determination of analyte in complex matrices was demonstrated. The proposed method was applied to the analysis of biological, industrial, natural and wastewater, soil and blood samples.   Keywords: 4-Amino-2,3-dimethyl-1-phenyl-3-pyrazoline-5-one (ADPP), N-Benzoyl-N-phenylhydroxylamine (BPA) ,   Cloud Point Extraction, Triton X-114, Flame Atomic Absorption Spectrometry.


Sign in / Sign up

Export Citation Format

Share Document