scholarly journals MICELLE-MEDIATED EXTRACTION AS A TOOL FOR SEPARATION AND PRECONCENTRATION IN COPPER ANALYSIS

2010 ◽  
Vol 7 (3) ◽  
pp. 278-283
Author(s):  
F. Ahmadia ◽  
A. Khanmohammadi ◽  
A. Malekpour

A cloud point extraction method was presented for preconcentration of copper in various samples. After complexation with 4-Amino-2,3-dimethyl-1-phenyl-3-pyrazoline-5-one (ADPP) or N-Benzoyl-N-phenylhydroxylamine (BPA)  in water, analyte ions are quantitatively extracted to the phase rich in Triton X-114 after centrifugation. 2.0 mol L-1 HNO3 solution in methanol was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The adopted concentrations for ADPP, Triton X-114, HNO3 and parameters such as bath temperature, centrifuge rate and time were optimized. Detection limits (3SDb/m) of 1.3 and 1.9 ng mL-1 for ADPP and BPA along with enrichment factors of 30 and 38 for ADPP and BPA were achieved. The high efficiency of cloud point extraction to carry out the determination of analyte in complex matrices was demonstrated. The proposed method was applied to the analysis of biological, industrial, natural and wastewater, soil and blood samples.   Keywords: 4-Amino-2,3-dimethyl-1-phenyl-3-pyrazoline-5-one (ADPP), N-Benzoyl-N-phenylhydroxylamine (BPA) ,   Cloud Point Extraction, Triton X-114, Flame Atomic Absorption Spectrometry.

2015 ◽  
Vol 52 (3) ◽  
pp. 178-186 ◽  
Author(s):  
Cennet Karadaş

A sensitive and simple cloud point extraction method was developed for simultaneous separation and preconcentration of cadmium and copper prior to their determination by flame atomic absorption spectrometry. 4-phenyl-3-thiosemicarbazide was used as complexing agent and the cadmium and copper complexes were extracted from the aqueous phase by Triton X-114 surfactant. The effects of parameters such as sample pH, ligand amount, concentration of surfactant, incubation temperature and time were optimized. For 20 mL of preconcentrated solution, the detection limits (3σ) were 0.20 and 0.49 μg L−1, and the enrichment factors were 20.7 and 19.9 for Cd(II) and Cu(II), respectively. In order to verify the accuracy of the developed method, certified reference materials (SLRS-5 river water and SPS-SW2 Batch 127 surface water) were analysed. Results obtained were in good agreement with the certified values. The proposed method was applied to tap water, river water and seawater samples with satisfactory results.


2012 ◽  
Vol 95 (6) ◽  
pp. 1797-1802 ◽  
Author(s):  
Mustafa Soylak ◽  
Erkan Yilmaz ◽  
Mehrorang Ghaedi ◽  
Mortaza Montazerozohori ◽  
Marjan Sheibani

Abstract A cloud point extraction procedure for the preconcentration of Pb2+ in various samples following complexation with 2,2-(1E,1′E)-1,1′-(2,2′-azanediylbis(ethane-2,1-diyl)bis(azan-1-yl-1-ylidene)) bis(ethan-1-yl-1-ylidene)diphenol in Triton X-114 after centrifugation is reported. A 0.5 mL portion of methanol acidified with 1.0 M HNO3 was added to the surfactant-rich phase prior to analysis by flame atomic absorption spectrometry. The influence of analytical parameters—including pH, concentrations of ligand, Triton X-114, and HNO3, bath temperature, heating time, and centrifugation rate and time—were optimized, and the effect of the matrix ions on the recovery of Pb2+ was investigated. An LOD of 1.9 ng/mL along with a preconcentration factor of 50 with RSD of 1.0% for Pb2+ were achieved. The proposed procedure was applied to the analysis of various real samples.


2009 ◽  
Vol 7 (1) ◽  
pp. 148-154 ◽  
Author(s):  
Mehrorang Ghaedi ◽  
Ardeshir Shokrollahi ◽  
Khodabakhsh Niknam ◽  
Ebrahim Niknam ◽  
Mustafa Soylak

AbstractA cloud point extraction procedure for the preconcentration of copper, nickel, iron and zinc ions in various samples has been described. Analyte ions in aqueous phase are complexed with 3-((indolin-3-yl)(phenyl)methyl)indoline (IYPMI) and following centrifugation quantitatively extracted to the aqueous phase rich in Triton X-114. The surfactant-rich phase was dissolved in 2.0 mol L−1 HNO3 in methanol prior to metal content determination by flame atomic absorption spectrometry (FAAS). The effects of some parameters including, the concentrations of IYPMI, Triton X-114 and HNO3, bath temperature, centrifuge rate and time were investigated on the recoveries of analyte ions. At optimum conditions, the detection limits of (3 SDb m−1) of 1.6, 2.8, 2.1 and 1.1 ng mL−1 for Cu2+, Fe3+, Ni2+ and Zn2+ along with preconcentration factors of 30 and enrichment factor of 48, 39, 34 and 52 for Cu2+, Ni2+, Fe3+ and Zn2+ respectively, were obtained. The proposed cloud point extraction has been successfully applied for the determination of metal ions in real samples with complicated matrix such as biological, soil and blood samples with high efficiency.


Sign in / Sign up

Export Citation Format

Share Document