Use of ion-selective electrodes in kinetic flow injection: determination of phenolic and hydrazino drugs with 1-fluoro-2,4-dinitrobenzene using a fluoride-selective electrode

The Analyst ◽  
1991 ◽  
Vol 116 (3) ◽  
pp. 233 ◽  
Author(s):  
John C. Apostolakis ◽  
Constantinos A. Georgiou ◽  
Michael A. Koupparis
2016 ◽  
Vol 13 (2) ◽  
pp. 458-469
Author(s):  
Baghdad Science Journal

A simple, fast, selective of a new flow injection analysis method coupled with potentiometric detection was used to determine vitamin B1 in pharmaceutical formulations via the prepared new selective membranes. Two electrodes were constructed for the determination of vitamin B1 based on the ion-pair vitamin B1-phosphotungestic acid (B1-PTA) in a poly (vinyl chloride) supported with a plasticized di-butyl phthalate (DBPH) and di-butyl phosphate (DBP). Applications of these ion selective electrodes for the determination of vitamin B1 in the pharmaceutical preparations for batch and flow injection systems were described. The ion selective membrane exhibited a near-Nernstian slope values 56.88 and 58.53 mV / decade, with the linear dynamic range of vitamin B1 was 5 x 10-5- 1 x 10-2 and 1 x 10-4-1 x 10-2 mol.L-1, in batch and FIA, respectively. The limit of detection was 3.5 x 10-5 and 9.5 x 10-5 mol.L-1, with the percentage linearity 98.85 and 95.22 in batch and FIA, respectively. The suggested ion selective electrode has been utilized perfection in the determination of vitamin B1 in pharmaceutical formulations using batch and flow injection system, respectively.


2009 ◽  
Vol 2009 ◽  
pp. 1-7 ◽  
Author(s):  
Hassan Arida ◽  
Mona Ahmed ◽  
Abdallah Ali

The fabrication and electrochemical evaluation of two PVC membrane-based Ion-Selective electrodes responsive for ramipril drug have been proposed. The sensitive membranes were prepared using ramipril-phosphomolibdate and ramipril-tetraphenylborate ion-pair complexes as electroactive sensing materials in plasticized PVC support. The electrodes based on these materials provide near-Nernestian response (sensitivity of53±0.5–54±0.5 mV/concentration decade) covering the concentration range of1.0×10-2–1.0×10-5 molL−1with a detection limit of3.0×10-6–4.0×10-6 molL−1. The suggested electrodes have been successfully used in the determination of ramipril drug in some pharmaceutical formulations using direct potentiometry with average recovery of >96% and mean standard deviation of <3% (n=5).


2016 ◽  
Vol 20 ◽  
pp. 73-75 ◽  
Author(s):  
Sumonmarn Chaneam ◽  
Waritta Taweetong ◽  
Kampanart Kaewyai ◽  
Pheeraphon Thienwong ◽  
Aekgaraj Takaew ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document