scholarly journals High speed color imaging through scattering media with a large field of view

2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Huichang Zhuang ◽  
Hexiang He ◽  
Xiangsheng Xie ◽  
Jianying Zhou
Sensors ◽  
2019 ◽  
Vol 19 (5) ◽  
pp. 996 ◽  
Author(s):  
Ran Chen ◽  
Zhongwei Li ◽  
Kai Zhong ◽  
Xingjian Liu ◽  
Yonghui Wu ◽  
...  

The ram speed of a steam hammer is an important parameter that directly affects the forming performance of forgers. This parameter must be monitored regularly in practical applications in industry. Because of the complex and dangerous industrial environment of forging equipment, non-contact measurement methods, such as stereo vision, might be optimal. However, in actual application, the field of view (FOV) required to measure the steam hammer is extremely large, with a value of 2–3 m, and heavy steam hammer, at high-speed, usually causes a strong vibration. These two factors combine to sacrifice the accuracy of measurements, and can even cause the failure of measurements. To solve these issues, a bundle-adjustment-principle-based system calibration method is proposed to realize high-accuracy calibration for a large FOV, which can obtain accurate calibration results when the calibration target is not precisely manufactured. To decrease the influence of strong vibration, a stationary world coordinate system was built, and the external parameters were recalibrated during the entire measurement process. The accuracy and effectiveness of the proposed technique were verified by an experiment to measure the ram speed of a counterblow steam hammer in a die forging device.


Author(s):  
Che-Hang Yu ◽  
Jeffrey N. Stirman ◽  
Yiyi Yu ◽  
Riichiro Hira ◽  
Spencer L. Smith

AbstractImaging the activity of neurons that are widely distributed across brain regions deep in scattering tissue at high speed remains challenging. Here, we introduce an open-source system with Dual Independent Enhanced Scan Engines for Large Field-of-view Two-Photon imaging (Diesel2p). Combining novel optical design, adaptive optics, and temporal multiplexing, the system offers subcellular resolution over a large field-of-view (∼ 25 mm2) with independent scan engines. We demonstrate the flexibility and various use cases of this system for calcium imaging of neurons in the living brain.


2018 ◽  
Vol 57 (26) ◽  
pp. 7533 ◽  
Author(s):  
Dongliang Tang ◽  
Sujit Kumar Sahoo ◽  
Vinh Tran ◽  
Cuong Dang

2019 ◽  
Vol 25 (S2) ◽  
pp. 46-47
Author(s):  
Yi Jiang ◽  
Junjing Deng ◽  
Jeffrey A. Klug ◽  
Yudong Yao ◽  
Curt Preissner ◽  
...  
Keyword(s):  

2017 ◽  
Vol 7 (1) ◽  
Author(s):  
Shaun Pacheco ◽  
Chengliang Wang ◽  
Monica K. Chawla ◽  
Minhkhoi Nguyen ◽  
Brend K. Baggett ◽  
...  

2013 ◽  
Vol 380-384 ◽  
pp. 3758-3761 ◽  
Author(s):  
Long Xu Jin ◽  
Jin Li ◽  
Xian Peng Hao

In order to satisfy the transmission of mass data volume of on-board time delay integration charge coupled devices (TDICCD) image, a high speed image transmission system of space panchromatic TDICCD camera with a large field of view is designed in this paper. A 4-channel parallel high speed transmission system for 16-channel CCD image was designed. A high speed serializer TLK2711 is applied to send and receive multi channel TDICCD images. A single chip TLK2711 can processing 4 channels image. Experimental results show that the designed transmission system can reliably work. The designed transmission system can meet the application for space TDICCD camera with a large field of view.


Sign in / Sign up

Export Citation Format

Share Document