scholarly journals Use of handheld X-ray fluorescence as a non-invasive method to distinguish between Asian and African elephant tusks

2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Kittisak Buddhachat ◽  
Chatchote Thitaram ◽  
Janine L. Brown ◽  
Sarisa Klinhom ◽  
Pakkanut Bansiddhi ◽  
...  
Author(s):  
S.U. Maksyukov ◽  
D.V. Yogina ◽  
D.S. Maksyukov

The aim of the study was to evaluate the effectiveness of a non-invasive method of treating caries at the stage of a white chalky spot with the Infiltration Concept (Icon) technology. Materials and methods: the clinical and laboratory study included 5 teeth with caries in the white spot stage, removed according to orthodontic indications. The study included scanning in an X-ray computer microtomograph of selected samples of teeth with caries in the white spot stage before and after treatment of the caries area according to Icon technology. For each sample, 1601 X-ray projections were obtained, which were then reconstructed using the XRM Reconstructor software. The comparison of the mineralization density of the samples was carried out by calibrating the obtained images, reconstructing three-dimensional models of tooth samples and constructing maps of the mineralization fee. Results and conclusions. Data on the mineralization density before and after treatment according to Icon technology were obtained in the following areas of the studied teeth: caries in the white spot stage; dentin bordering on caries (the area touches the dentinoemal border as close as possible to the caries area); the area of healthy enamel on the opposite side of the tooth; dentin bordering on healthy enamel (near the dentinoemal border and as close as possible to the healthy enamel area). A comparison of the results obtained does not allow us to conclude about the effectiveness of treatment according to the Icon technology. Moreover, the mineralization density of the studied areas significantly decreased after the treatment.


1996 ◽  
Vol 42 (3) ◽  
pp. 29-32
Author(s):  
I. O. Tomashevsky

The technology of non-invasive determination of the level of intrathyroid stable iodine (ISI), called X-ray fluorescence analysis or X-ray fluorescence scanning, began to be used since 1968 and is currently used in approximately 10 radiological laboratories around the world as a unique research methodology. Only in recent years have the technical difficulties of this diagnostic method been overcome, and it is gradually becoming more accessible. Since 1974, the efforts of the staff of the Radiological Scientific Center of the Russian Academy of Medical Sciences (Obninsk) and the clinical hospital of the Central Health Unit No. 119 of the Federal Administration for Biomedical and Extreme Problems at the Ministry of Health of the Russian Federation (Khimki) carried out the necessary scientific research and created an analyzer, a method for determining the level ISI and interpretations of the results obtained, allowed for use in Russia as serial laboratory technologies. The specified diagnostic method over the past few years has been successfully used in these institutions when examining more than 3,000 patients with various thyroid diseases (thyroid gland) and continues to be used in the comprehensive diagnosis of thyroid pathology. The purpose of this lecture is to familiarize endocrinologists with the diagnostic capabilities of this method.


Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


2001 ◽  
Vol 12 (1) ◽  
pp. 8-14
Author(s):  
Gertraud Teuchert-Noodt ◽  
Ralf R. Dawirs

Abstract: Neuroplasticity research in connection with mental disorders has recently bridged the gap between basic neurobiology and applied neuropsychology. A non-invasive method in the gerbil (Meriones unguiculus) - the restricted versus enriched breading and the systemically applied single methamphetamine dose - offers an experimental approach to investigate psychoses. Acts of intervening affirm an activity dependent malfunctional reorganization in the prefrontal cortex and in the hippocampal dentate gyrus and reveal the dopamine position as being critical for the disruption of interactions between the areas concerned. From the extent of plasticity effects the probability and risk of psycho-cognitive development may be derived. Advance may be expected from insights into regulatory mechanisms of neurogenesis in the hippocampal dentate gyrus which is obviously to meet the necessary requirements to promote psycho-cognitive functions/malfunctions via the limbo-prefrontal circuit.


2020 ◽  
Vol 13 (4) ◽  
pp. 184-190
Author(s):  
Muhammad Irfan ◽  
Abdul Rasheed Qureshi ◽  
Zeeshan Ashraf ◽  
Muhammad Amjad Ramzan ◽  
Tehmina Naeem ◽  
...  

ABSTRACT Background: Conventionally Pleural effusions are suspected by history of pleuritis, evaluated by physical signs and multiple view radiography. Trans-thoracic pleural aspiration is done and aspirated pleural fluid is considered the gold-standard for pleural effusion. Chest sonography has the advantage of having high diagnostic efficacy over radiography for the detection of pleural effusion. Furthermore, ultrasonography is free from radiation hazards, inexpensive, readily available  and feasible for use in ICU, pregnant and pediatric patients. This study aims to explore the diagnostic accuracy of trans-thoracic ultrasonography for pleural fluid detection, which is free of such disadvantages. The objective is to determine the diagnostic efficacy of trans-thoracic ultrasound for detecting pleural effusion and also to assess its suitability for being a non-invasive gold-standard.   Subject and Methods: This retrospective study of 4597 cases was conducted at pulmonology  OPD-Gulab Devi Teaching Hospital, Lahore from November 2016 to July 2018. Adult patients with clinical features suggesting pleural effusions were included while those where no suspicion of pleural effusion, patients < 14 years and pregnant ladies were excluded. Patients were subjected to chest x-ray PA and Lateral views and chest ultrasonography was done by a senior qualified radiologist in OPD. Ultrasound-guided pleural aspiration was done in OPD & fluid was sent for analysis. At least 10ml aspirated fluid was considered as diagnostic for pleural effusion. Patient files containing history, physical examination, x-ray reports, ultrasound reports, pleural aspiration notes and informed consent were retrieved, reviewed and findings were recorded in the preformed proforma. Results were tabulated and conclusion was drawn by statistical analysis. Results: Out of 4597 cases, 4498 pleural effusion were manifested on CXR and only 2547(56.62%) pleural effusions were proved by ultrasound while 2050 (45.57%) cases were reported as no Pleural effusion. Chest sonography demonstrated sensitivity, specificity, PPV, NPV and diagnostic accuracy 100 % each. Conclusions: Trans-thoracic ultrasonography revealed an excellent efficacy that is why it can be considered as non-invasive gold standard for the detection of pleural effusion.


Sign in / Sign up

Export Citation Format

Share Document