Bond index interpretation of valence isomerization

1971 ◽  
Vol 93 (9) ◽  
pp. 2330-2331 ◽  
Author(s):  
Myung-Hwan Whangbo ◽  
Ikchoon Lee
ChemInform ◽  
1990 ◽  
Vol 21 (46) ◽  
Author(s):  
M. M. RAHMAN ◽  
B. A. SECOR ◽  
K. M. MORGAN ◽  
P. R. SHAFER ◽  
D. M. LEMAL

2007 ◽  
Vol 119 (30) ◽  
pp. 5843-5847 ◽  
Author(s):  
Jean-Baptiste Bourg ◽  
Amor Rodriguez ◽  
David Scheschkewitz ◽  
Heinz Gornitzka ◽  
Didier Bourissou ◽  
...  

2021 ◽  
Author(s):  
Subhadeep Sarkar ◽  
Mathias Horstmann ◽  
Tore Oian ◽  
Piotr Byrski ◽  
George Lawrence ◽  
...  

Abstract One of the crucial components of well integrity evaluation in offshore drilling is to determine the cement bond quality assuring proper hydraulic sealing. On the Norwegian Continental Shelf (NCS) an industry standard as informative reference imposes verification of cement length and potential barriers using bonding logs. Traditionally, for the last 50 years, wireline (WL) sonic tools have been extensively used for this purpose. However, the applicability of logging-while-drilling (LWD) sonic tools for quantitative cement evaluation was explored in the recent development drilling campaign on the Dvalin Field in the Norwegian Sea, owing to significant advantages on operational efficiency and tool conveyance in any well trajectory. Cement bond evaluation from conventional peak-to-peak amplitude method has shown robust results up to bond indexes of 0.6 for LWD sonic tools. Above this limit, the casing signal is smaller than the collar signal and the amplitude method loses sensitivity to bonding. This practical challenge in the LWD realm was overcome through the inclusion of attenuation rate measurements, which responds accordingly in higher bonding environments. The two methods are used in a hybrid approach providing a full range quantitative bond index (QBI) introduced by Izuhara et al. (2017). In order to conform with local requirements related to well integrity and to ascertain the QBI potential from LWD monopole sonic, a wireline cement bond log (CBL) was acquired in the first well of the campaign for comparison. This enabled the strategic deployment of LWD QBI service in subsequent wells. LWD sonic monopole data was acquired at a controlled speed of 900ft/h. The high-fidelity waveforms were analyzed in a suitable time window and both amplitude- and attenuation-based bond indexes were derived. The combined hybrid bond index showed an excellent match with the wireline reference CBL, both in zones of high as well as lower cement bonding. The presence of formation arrivals was also in good correlation with zones of proper bonding distinguishable on the QBI results. This established the robustness of the LWD cement logging and ensured its applicability in the rest of the campaign which was carried out successfully. While the results from LWD cement evaluation service are omnidirectional, it comes with a wide range of benefits related to rig cost or conveyance in tough borehole trajectories. Early evaluation of cement quality by LWD sonic tools helps to provide adequate time for taking remedial actions if necessary. The LWD sonic as part of the drilling BHA enables this acquisition and service in non-dedicated runs, with the possibility of multiple passes for observing time-lapse effects. Also, the large sizes of LWD tools relative to the wellbore ensures a lower signal attenuation in the annulus and more effective stabilization, thereby providing a reliable bond index.


2018 ◽  
Author(s):  
Thomas Nahmer

Dieses Papier untersucht die Sinnhaftigkeit von Fine Wine als Alternatives Investment unter besonderer Berücksichtigung der Kosten eines Fine Wine Investments. Ist Fine Wine zur weiteren Diversifizierung und damit zur Verbesserung des Risikio-Return-Profils von global in Aktien und Anleihen investierenden Portfolios geeignet? Die Analyse erfolgt in einem ersten Schritt auf Indexbasis und in einem zweiten Schritt auf Basis von realen Investitions-möglichkeiten. Die Referenzwährungen sind der US-Dollar und der Euro. Für die Indexbetrachtung werden auf der Aktienseite der MSCI-World-Index und für die Anleihen der JPM-World-Government-Bond-Index verwendet. Bei den Daten für die Investition in Fine Wine liegt der Fokus auf dem Liv-ex-50-Index der im Jahre 1999 gegründeten Londoner Weinbörse Liv-ex. Bei der realen Investition werden für die Datenanalyse bei Aktien und Anleihen Indexfonds verwendet. Da es für die Investition in Fine Wine keinen Indexfonds gibt, wird der Liv-ex-50-Index inklusive aller Kosten einer realen Investition berechnet. Es werden verschiedene Portfoliozusammensetzungen verglichen. Zum einen wird ein Portfolio aus 50% Aktien und 50% Anleihen einem Portfolio aus 45% Aktien, 45% Anleihen und 10% Fine Wine gegenübergestellt. Zum an-deren wird ein Portfolio aus 25% Aktien und 75% Anleihen gegen ein Portfolio aus 20% Aktien, 70% Anleihen und 10% Fine Wine gemessen. Als Vergleichsmaßstab werden die annualisierte Rendite, die Standardabweichung sowie das Sharpe-Ratio der jeweiligen Portfolios berechnet. Die Ergebnisse für die genannten Zeiträume sind ernüchternd. Die Beimischung von Fine Wine führt auf Indexebene lediglich zu einer leichten Verbesserung der annualisierten Rendite aber zu einer markanten Erhöhung des Risi-kos. Bei der Betrachtung der realen Investition kommen die hohen Kosten eines Investments in Fine Wine zum Tragen. Die annualisierte Rendite ist im Vergleich zu den Portfolios ohne Beimischung von Fine Wine niedriger bei gleichzeitig höheren Risikowerten. Lediglich bei der Betrachtung auf Indexbasis in Euro kann bei einem Portfolio eine leichte Verbesserung der Sharpe-Ratio verzeichnet werden. Bei der Betrachtung nach Kosten führt in allen Fällen die Beimischung von Fine Wine zu einer Verschlechterung der Sharpe-Ratios.


1981 ◽  
Vol 10 (7) ◽  
pp. 839-842 ◽  
Author(s):  
Kazuhiro Maruyama ◽  
Kazutoshi Terada ◽  
Yoshinori Yamamoto

Sign in / Sign up

Export Citation Format

Share Document