Average Heat Transfer Coefficients from Plasma Gases to an Internally-Finned Tube. Engineering Correlations

1971 ◽  
Vol 10 (1) ◽  
pp. 122-125 ◽  
Author(s):  
Richard J. Henry
1978 ◽  
Vol 100 (1) ◽  
pp. 17-24 ◽  
Author(s):  
J. H. Royal ◽  
A. E. Bergles

Low pressure steam was condensed inside horizontal tubes of different internal geometries to investigate passive heat transfer augmentation techniques. A smooth tube, the smooth tube having two twisted-tape inserts, and four internally finned tubes were tested. The twisted-tape inserts were found to increase average heat transfer coefficients by as much as 30 percent above smooth tube values on a nominal area basis. The best performing internally finned tube increased average heat transfer coefficients by 150 percent above the nominal smooth tube values. Techniques were developed to correlate the improved heat transfer performance of the two twisted-tape inserts and the four internally finned tubes. The equations developed provide a reasonably accurate description of both the sectional and the average heat transfer coefficients. The finned tube correlation was also reasonably successful in predicting the data from the one other investigation of this augmentation technique for which detailed data were available.


1987 ◽  
Vol 109 (2) ◽  
pp. 388-391 ◽  
Author(s):  
E. M. Sparrow ◽  
M. A. Ansari

Measurements were made of the combined natural convection and radiation heat transfer from a horizontal finned tube situated in a vertical channel open at the top and bottom. In one set of experiments, both walls of the channel were heavily insulated, while in a second set of experiments, one of the insulated walls was replaced by an uninsulated metallic sheet. In general, the heat transfer coefficients were found to be lower with the metal wall in place, but only moderately. With the finned tube situated at the bottom of the channel, the differences in the heat transfer coefficients corresponding to the two types of walls were only a few percent. When the tube was positioned at the mid-height of the channel, larger differences were encountered, but in the practical range of Rayleigh numbers, the differences did not exceed 5 percent.


1981 ◽  
Vol 103 (4) ◽  
pp. 705-714 ◽  
Author(s):  
J. C. Biery

A new method is presented to predict heat transfer coefficients for gas flow normal to smooth and finned tube tanks with triangular pitch. A transformation from the actual tube bank to an equivalent equilateral triangular pitch infinite smooth tube bank (ETP-I-STB) is made. A function of Ch(Ch = NSTNPR2/3NRe0.4) versus (Xt D0)Δ, ratio of transverse pitch to tube diameter for the ETP-I-STB, was developed. The Ch for the equivalent ETP-I-STP then applies to the actual tube bank. The method works with circular finned tubes, smooth tubes, continuous finned tubes, and segmented finned tubes with any triangular pitch. Also, fair predictions were made for in-line tubes with high Reynolds numbers.


1997 ◽  
Vol 119 (2) ◽  
pp. 381-389 ◽  
Author(s):  
M. E. Taslim ◽  
C. M. Wadsworth

Turbine blade cooling, a common practice in modern aircraft engines, is accomplished, among other methods, by passing the cooling air through an often serpentine passage in the core of the blade. Furthermore, to enhance the heat transfer coefficient, these passages are roughened with rib-shaped turbulence promoters (turbulators). Considerable data are available on the heat transfer coefficient on the passage surface between the ribs. However, the heat transfer coefficients on the surface of the ribs themselves have not been investigated to the same extent. In small aircraft engines with small cooling passages and relatively large ribs, the rib surfaces comprise a large portion of the passage heat transfer area. Therefore, an accurate account of the heat transfer coefficient on the rib surfaces is critical in the overall design of the blade cooling system. The objective of this experimental investigation was to conduct a series of 13 tests to measure the rib surface-averaged heat transfer coefficient, hrib, in a square duct roughened with staggered 90 deg ribs. To investigate the effects that blockage ratio, e/Dh and pitch-to-height ratio, S/e, have on hrib and passage friction factor, three rib geometries corresponding to blockage ratios of 0.133, 0.167, and 0.25 were tested for pitch-to-height ratios of 5, 7, 8.5, and 10. Comparisons were made between the rib average heat transfer coefficient and that on the wall surface between two ribs, hfloor, reported previously. Heat transfer coefficients of the upstream-most rib and that of a typical rib located in the middle of the rib-roughened region of the passage wall were also compared. It is concluded that: 1 The rib average heat transfer coefficient is much higher than that for the area between the ribs; 2 similar to the heat transfer coefficient on the surface between the ribs, the average rib heat transfer coefficient increases with the blockage ratio; 3 a pitch-to-height ratios of 8.5 consistently produced the highest rib average heat transfer coefficients amongst all tested; 4 under otherwise identical conditions, ribs in upstream-most position produced lower heat transfer coefficients than the midchannel positions, 5 the upstream-most rib average heat transfer coefficients decreased with the blockage ratio; and 6 thermal performance decreased with increased blockage ratio. While a pitch-to-height ratio of 8.5 and 10 had the highest thermal performance for the smallest rib geometry, thermal performance of high blockage ribs did not change significantly with the pitch-to-height ratio.


Author(s):  
Rui Kan ◽  
Li Yang ◽  
Jing Ren ◽  
Hongde Jiang

Thermal issues of gas turbine blade trailing edge are complex and challenging, due to limited space for effective cooling. The trailing edge cavities are usually large aspect ratio ducts with lateral ejection. The objective of this study is to investigate the effects of different rib configurations and lateral ejection on heat transfer characteristics inside a trailing edge channel. The investigations were conducted on a large aspect ratio wedge-shaped channel with square ribs of e/Dh = 0.05, under Reynolds number 15,000. Twelve different configurations were tested: 1)three rib types, including a symmetry V-shaped rib configuration and two non-symmetry V-shaped rib configurations, of which the rib angles are 60 degrees, 2) two rib pitches, P/e = 10 and P/e = 5, 3) two flow directions, with an open tip outlet or with lateral ejection. Spatially resolved heat transfer distributions were obtained using the transient thermochromic liquid crystal experimental method. The configurations were also investigated numerically for the detailed flow field and for the validation of CFD codes. Results show that with lateral ejection, the heat transfer coefficients decrease from inlet to outlet. The heat transfer near the ejection holes is enhanced while heat transfer coefficients near the wall opposite to the exit holes decrease. The curvature of the streamlines creates a large separation area near the end of the channel and thus results in low local heat transfer coefficients. The P/e = 10 configurations have higher average heat transfer compared with P/e = 5 configurations. Average heat transfer coefficient is the highest with the center of the V-shaped rib placed at the middle of the channel, and is the lowest when the V-shaped rib center is located near the narrow part of the channel.


1985 ◽  
Vol 107 (2) ◽  
pp. 307-312 ◽  
Author(s):  
D. G. Motwani ◽  
U. N. Gaitonde ◽  
S. P. Sukhatme

Average heat transfer coefficients during forced convection air flow over inclined and yawed rectangular plates have been experimentally determined. Tripping wires at the edges ensured that a turbulent boundary layer prevailed over the plates. The experiments were carried out for a constant surface temperature and covered two plates of different aspect ratios, angles of attack from 0 to 45 deg, angles of yaw from 0 to 30 deg, and Reynolds numbers from 2 times; 104 to 3.5 times; 105. The results show that the average heat transfer coefficient is essentially insensitive to the aspect ratio and angle of yaw. However, it is a function of Reynolds number and the angle of attack. Correlation equations for various angles of attack are suggested.


1966 ◽  
Vol 88 (1) ◽  
pp. 101-107 ◽  
Author(s):  
Robert Gardon ◽  
J. Cahit Akfirat

Local as well as average heat transfer coefficients between an isothermal flat plate and impinging two-dimensional jets were measured for both single jets and arrays of jets. For a large and technologically important range of variables the results have been correlated in relatively simple terms, and their application to design is briefly considered.


1998 ◽  
Vol 120 (2) ◽  
pp. 376-385 ◽  
Author(s):  
G. J. Korotky ◽  
M. E. Taslim

Three staggered 90 deg rib geometries corresponding to blockage ratios of 0.133, 0.167, and 0.25 were tested for pitch-to-height ratios of 5, 8.5, and 10, and for two distinct thermal boundary conditions of heated and unheated channel walls. Comparisons were made between the surface-averaged heat transfer coefficients and friction factors for ribs with rounded corners and those with sharp corners, reported previously. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the rib-roughened region of the passage wall were also compared. It was concluded that: (a) For the geometries tested, the rib average heat transfer coefficient was much higher than that for the area between the ribs. For the sharp-corner ribs, the rib average heat transfer coefficient increased with blockage ratio. However, when the corners were rounded, the trend depended on the level of roundness. (b) High-blockage-ratio (e/Dh = 0.25) ribs were insensitive to the pitch-to-height ratio. For the other two blockage ratios, the pitch-to-height ratio of 5 produced the lowest heat transfer coefficient. Results of the other two pitch-to-height ratios were very close, with the results of S/e = 10 slightly higher than those of S/e = 8.5. (c) Under otherwise identical conditions, ribs in the furthest upstream position produced lower heat transfer coefficients for all cases except that of the smallest blockage ratio with S/e of 5. In that position, for the rib geometries tested, while the sharp-corner rib average heat transfer coefficients increased with the blockage ratio, the trend of the round-corner ribs depended on the level of roundness, r/e. (d) Thermal performance decreased with the blockage ratio. While the smallest rib geometry at a pitch-to-height ratio of 10 had the highest thermal performance, thermal performance of high blockage ribs at a pitch-to-height ratio of 5 was the lowest. (e) The general effects of rounding were a decrease in heat transfer coefficient for the midstream ribs and an increase in heat transfer coefficient for ribs in the furthest upstream position.


Sign in / Sign up

Export Citation Format

Share Document