Unified Membrane Fouling Index for Low Pressure Membrane Filtration of Natural Waters: Principles and Methodology

2008 ◽  
Vol 42 (3) ◽  
pp. 714-720 ◽  
Author(s):  
Haiou Huang ◽  
Thayer A. Young ◽  
Joseph G. Jacangelo
2008 ◽  
Vol 8 (1) ◽  
pp. 75-83
Author(s):  
NoHwa Lee ◽  
John Pellegrino ◽  
Gary Amy

This research attempted to identify characteristic coordinates responsible for significant flux decline in low pressure membrane filtration, and to explain relationships among those coordinates with a modeling approach. A Pearson's correlation matrix supported that significant flux decline over a short time frame (low delivered DOC) is highly correlated with high molecular weight (MW) components of NOM. Simulations of flux decline by model equations were close to the experimental results revealing that low pressure membrane fouling is dominantly affected by NOM characteristics and membrane properties. One source water, exhibiting the highest flux decline, showed mostly cake formation as a fouling mechanism. The results indicate that significant flux decline is caused by high MW components leading to formation of a cake layer. Principal component analysis (PCA) revealed that high MW polysaccharides are the most important NOM component affecting significant membrane fouling.


2012 ◽  
Vol 2 (2) ◽  
pp. 74-83 ◽  
Author(s):  
C. Ayache ◽  
M. Pidou ◽  
W. Gernjak ◽  
Y. Poussade ◽  
J.-P. Croué ◽  
...  

This study evaluates the impacts of water quality from three different secondary effluents on low pressure membrane fouling. Effluent organic matter (EfOM) has been reported by previous studies as responsible for membrane fouling. However, the contribution of the different components of EfOM to membrane fouling is still not well understood. In order to improve and optimize treatment processes, characterization and quantification of the organic matter are important. The characterization methods used in this study are liquid chromatography coupled with an organic detector (LC-OCD) and excitation emission matrix fluorescence spectroscopy (EEM). A bench-scale hollow fibre membrane system was used to identify the type of fouling depending on the feed water quality. Results showed no measurable dissolved organic carbon removal by the membranes for the three secondary effluents. Biopolymers and humic-like substances found in different proportions in the three effluents were partially retained by the membranes and were identified to contribute significantly to the flux decline of the low pressure membranes. The observed fouling was determined to be reversible by hydraulic backwashing for two effluents and only by chemical cleaning for the third effluent.


Water ◽  
2019 ◽  
Vol 11 (8) ◽  
pp. 1592
Author(s):  
Hashimoto ◽  
Gunawan ◽  
Wattanachira ◽  
Wongrueng ◽  
Takizawa

Natural waters in tropical countries are turbid and rich in inorganic substances such as iron and manganese. Hence, membrane fouling by these inorganic substances is the most serious problem in membrane filtration processes for potable water production. This study aimed to assess raw water storage as a simple but effective means for controlling membrane fouling in the filtration of river water in a tropical country. Raw water taken from the Ping River in Chiang Mai, Thailand, in different seasons, was either immediately filtered or stored in a tank for two days before filtration through a polyvinylidene difluoride (PVDF) membrane with a nominal pore size of 0.1 μm. The turbidity and particulate organic carbon (POC) in the raw water were reduced by storage, while dissolved manganese was oxidized during the storage period. Although the amounts of metallic substances retained on membranes were larger than those of silica and organic matter, their contribution to the fouling resistance was found to be less than silica and organic carbon. The fouling analysis using hydraulically irreversible fouling index (HIFI) was found to be not able to measure the effects of storage when the initial flux increased. Hence, the ratio of the hydraulically reversible fouling index (HRFI) to the total fouling index (TFI), i.e., HRFI/TFI, was proposed to elucidate the effects of raw water storage on membrane fouling, which was manifest during the early stage of membrane filtration operation.


2020 ◽  
Vol 241 ◽  
pp. 116644 ◽  
Author(s):  
Arslan Ahmad ◽  
Sam Rutten ◽  
Luuk de Waal ◽  
Peter Vollaard ◽  
Case van Genuchten ◽  
...  

2008 ◽  
Vol 325 (1) ◽  
pp. 50-57 ◽  
Author(s):  
Haiou Huang ◽  
Thayer A. Young ◽  
Joseph G. Jacangelo

2010 ◽  
Vol 5 (4) ◽  
Author(s):  
J. L. Manuszak ◽  
M. MacPhee ◽  
S. Liskovich ◽  
L. Feldsher

The City of Baltimore, Maryland is one of many US cities faced with challenges related to increasing potable water demands, diminishing fresh water supplies, and aging infrastructure. To address these challenges, the City recently undertook a $7M study to evaluate water supply and treatment alternatives and develop the conceptual design for a new 120 million gallon per day (MGD) water treatment plant. As part of this study, an innovative raw water management tool was constructed to help model source water availability and predicted water quality based on integration of a new and more challenging surface water supply. A rigorous decision-making approach was then used to screen and select appropriate treatment processes. Short-listed treatment strategies were demonstrated through a year-long pilot study, and process design criteria were collected in order to assess capital and operational costs for the full-scale plant. Ultimately the City chose a treatment scheme that includes low-pressure membrane filtration and post-filter GAC adsorption, allowing for consistent finished water quality irrespective of which raw water supply is being used. The conceptual design includes several progressive concepts, which will: 1) alleviate treatment limitations at the City's existing plants by providing additional pre-clarification facilities at the new plant; and 2) take advantage of site conditions to design and operate the submerged membrane system by gravity-induced siphon, saving the City significant capital and operations and maintenance (O&M) costs. Once completed, the new Fullerton Water Filtration Plant (WFP) will be the largest low-pressure membrane plant in North America, and the largest gravity-siphon design in the world.


2004 ◽  
Vol 4 (5-6) ◽  
pp. 215-222 ◽  
Author(s):  
A.R. Costa ◽  
M.N. de Pinho

Membrane fouling by natural organic matter (NOM), namely by humic substances (HS), is a major problem in water treatment for drinking water production using membrane processes. Membrane fouling is dependent on membrane morphology like pore size and on water characteristics namely NOM nature. This work addresses the evaluation of the efficiency of ultrafiltration (UF) and Coagulation/Flocculation/UF performance in terms of permeation fluxes and HS removal, of the water from Tagus River (Valada). The operation of coagulation with chitosan was evaluated as a pretreatment for minimization of membrane fouling. UF experiments were carried out in flat cells of 13.2×10−4 m2 of membrane surface area and at transmembrane pressures from 1 to 4 bar. Five cellulose acetate membranes were laboratory made to cover a wide range of molecular weight cut-off (MWCO): 2,300, 11,000, 28,000, 60,000 and 75,000 Da. Severe fouling is observed for the membranes with the highest cut-off. In the permeation experiments of raw water, coagulation prior to membrane filtration led to a significant improvement of the permeation performance of the membranes with the highest MWCO due to the particles and colloidal matter removal.


Membranes ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 460
Author(s):  
Bastiaan Blankert ◽  
Bart Van der Bruggen ◽  
Amy E. Childress ◽  
Noreddine Ghaffour ◽  
Johannes S. Vrouwenvelder

The manner in which membrane-fouling experiments are conducted and how fouling performance data are represented have a strong impact on both how the data are interpreted and on the conclusions that may be drawn. We provide a couple of examples to prove that it is possible to obtain misleading conclusions from commonly used representations of fouling data. Although the illustrative example revolves around dead-end ultrafiltration, the underlying principles are applicable to a wider range of membrane processes. When choosing the experimental conditions and how to represent fouling data, there are three main factors that should be considered: (I) the foulant mass is principally related to the filtered volume; (II) the filtration flux can exacerbate fouling effects (e.g., concentration polarization and cake compression); and (III) the practice of normalization, as in dividing by an initial value, disregards the difference in driving force and divides the fouling effect by different numbers. Thus, a bias may occur that favors the experimental condition with the lower filtration flux and the less-permeable membrane. It is recommended to: (I) avoid relative fouling performance indicators, such as relative flux decline (J/J0); (II) use resistance vs. specific volume; and (III) use flux-controlled experiments for fouling performance evaluation.


Membranes ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 369
Author(s):  
Shengji Xia ◽  
Xinran Zhang ◽  
Yuanchen Zhao ◽  
Fibor J. Tan ◽  
Pan Li ◽  
...  

The membrane separation process is being widely used in water treatment. It is very important to control membrane fouling in the process of water treatment. This study was conducted to evaluate the efficiency of a pre-oxidation-coagulation flat ceramic membrane filtration process using different oxidant types and dosages in water treatment and membrane fouling control. The results showed that under suitable concentration conditions, the effect on membrane fouling control of a NaClO pre-oxidation combined with a coagulation/ceramic membrane system was better than that of an O3 system. The oxidation process changed the structure of pollutants, reduced the pollution load and enhanced the coagulation process in a pre-oxidation-coagulation system as well. The influence of the oxidant on the filtration system was related to its oxidizability and other characteristics. NaClO and O3 performed more efficiently than KMnO4. NaClO was more conducive to the removal of DOC, and O3 was more conducive to the removal of UV254.


Sign in / Sign up

Export Citation Format

Share Document